Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex robust 210/215 c control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Lead Paragraph
OLFLEX ROBUST 210 is an all-weather TPE control cable for fixed installation and occasional flexing in chemically aggressive environments. Its special TPE sheath resists oils, animal and vegetable fats, ammonia compounds, ozone and UV to EN 50396, and withstands freshwater immersion to 10 m. Two variants share Class 5 bare-copper conductors, black numbered cores and −50 °C to +80 °C fixed range: ROBUST 215 C adds a tinned-copper braided screen for EMC protection plus TW-1 (≥ -20 °C) / TW-2 (≥ -40 °C) torsion ratings, the choice where a drive or inverter sits alongside a weather-exposed route. Select unscreened ROBUST 210 for food, agricultural and chemical plant wiring, screened ROBUST 215 C for machine tool, wind turbine jumper and EMC-sensitive runs.
Select Your Variant
In short: ROBUST 215 C = ROBUST 210 + EMC screen + torsion ratings TW-1 / TW-2 + halogen-free foil wrap, at the cost of a lower core ceiling (25 vs 50 cores) and tighter bending radius limits.
By Application Requirement
|
Requirement |
Recommended Variant |
Typical Application |
|
No EMC shielding needed |
ROBUST 210 |
Food processing, agriculture, chemical plant, outdoor routing |
|
EMC shielding required |
ROBUST 215 C |
Machine tools with VFDs, EMC-sensitive control circuits |
|
Wind turbine torsion (WTG jumper) |
ROBUST 215 C |
Nacelle jumper section, ±150°/m torsion, TW-1/TW-2 |
|
Maximum core count (up to 50) |
ROBUST 210 |
Large multi-core control harnesses |
|
Freshwater immersion (10 m) |
Both variants |
Washdown zones, waterside plant installations |
Typical Applications

Chemical, fertiliser and wastewater plant
Both variants
The run leaves the process area on tray and continues into the yard, so the sheath meets chemicals on one side and weather on the other. Both variants are rated for indoor and outdoor installation, with ozone and UV assessed to EN 50396.

Food and beverage processing, washdown
Both variants
Lines are washed down with hot water and steam between batches, so the cable sees immersion as well as cleaning. Both variants take steam cleaning and 10 m freshwater immersion at +40 °C, with TM5 oil resistance to EN 50363-4-1.

Machine tools with variable-frequency drives
ROBUST 215 C
The drive shares the cabinet with the control wiring, and the tinned-copper braid is what lets one cable do both jobs. No separate screened run is needed for the EMC-sensitive cores

Wind turbine nacelle jumper section
ROBUST 215 C
The run moves with the nacelle, so the specification is set by torsion class rather than by bend radius. ROBUST 215 C is rated TW-1 (≥ −20 °C) and TW-2 (≥ −40 °C) at ± 150° per metre, 2000 cycles each.
Why Choose OLFLEX ROBUST 210 / 215 C Series
All-Weather TPE Sheath - Stays Flexible from -50 °C to +80 °C Fixed
The special TPE compound maintains flexibility at -50 °C for fixed installation and -40 °C during occasional flexing - no companion cold-climate grade required. At the high end, an +80 °C rating covers elevated-temperature enclosures and engine rooms in a single cable selection.
01
Certified Oil Resistance (TM5) - Purpose-Built for Food, Agriculture and Chemical Plant
Oil resistance is proven to EN 50363-4-1 (TM5), covering animal and vegetable oils, bio-oils, emulsions, waxes, greases, ammonia compounds and biogas. Combine this with steam-cleaning tolerance and 10 m freshwater immersion, and the cable meets the most demanding hygiene-plant routing requirements without a secondary protection layer.
02
ROBUST 215 C - Screened, Torsion-Rated All-Weather Control Cable
Where both electromagnetic cleanliness and torsional movement coexist - typically in wind turbine nacelle jumper sections or machine tool cabinets with variable-frequency drives - ROBUST 215 C provides a tinned-copper braided screen and TW-1 / TW-2 torsion ratings in a single cable. Ordering a separate screened type and a separate torsion-rated type for the same run becomes unnecessary.
03
ROBUST 210 - Unscreened All-Weather Control Cable, up to 50 Cores
Black insulation with white sequential numbers (VDE 0293-1) speeds up termination and reduces mis-wiring where many control cores converge. As the unscreened member of the series, ROBUST 210 carries the widest core range in the ROBUST family: 50 cores at 0.75, 1.0 and 1.5 mm², with 34- and 41-core constructions available only in this variant. High-count runs therefore need no cable bundling.
04
Product Structure
|
Layer |
ROBUST 210 |
ROBUST 215 C |
|
① Conductor |
Class 5 fine-wire bare copper (VDE 0295 / IEC 60228) |
Class 5 fine-wire bare copper (VDE 0295 / IEC 60228) |
|
② Insulation |
Modified PP |
Modified PP |
|
③ Core Identification |
Black cores with white sequential numbers (VDE 0293-1) |
Black cores with white sequential numbers (VDE 0293-1) |
|
④ Core wrap |
None |
Halogen-free plastic foil |
|
⑤ Screen |
None |
Tinned-copper braided screen |
|
⑥ Outer Sheath |
Special TPE, black RAL 9005 |
Special TPE, black RAL 9005 |
Frequently Asked Questions
Q: What environments is the ROBUST series designed for?
A: Both ROBUST 210 and 215 C are built for fixed installation and occasional flexing in chemically aggressive, wet and outdoor environments. The special TPE sheath resists oils, animal and vegetable fats, ammonia compounds, ozone and UV. They are not intended for continuous drag-chain travel.
Q: What is the difference between ROBUST 210 and ROBUST 215 C?
A: ROBUST 215 C adds a tinned-copper braided screen for EMC protection, torsion ratings TW-1 (≥ −20 °C) and TW-2 (≥ −40 °C), and a halogen-free plastic foil core wrap - at the cost of a larger bend radius: 6 × OD fixed, 20 × OD for occasional flexing. ROBUST 210 is unscreened and carries no torsion rating, but it reaches 50 cores at 0.75–1.5 mm², including the 34- and 41-core builds the screened type does not offer. Both variants are rated for 10 m freshwater immersion at +40 °C.
Q: Can ROBUST 215 C be used in wind turbine torsion applications?
A: Yes. ROBUST 215 C is rated TW-1 (>= -20 C, +/-150/m, 2000 cycles) and TW-2 (>= -40 C, +/-150/m, 2000 cycles), covering the torsional movement typical of WTG nacelle jumper sections. ROBUST 210 is not rated for torsion.
Q: Is the ROBUST series oil-resistant?
A: Yes. Both variants are oil-resistant to EN 50363-4-1 (TM5), covering mineral oils, animal and vegetable oils, bio-oils, emulsions, waxes, greases and water-soluble coolants. The sheath also tolerates ammonia compounds and biogas found in agricultural and food processing environments.
Q: What do G and X mean in the designation?
A: The letter G marks a construction that carries a green-yellow protective conductor; X marks one that does not. Taking 3G0.5 as an example, its three cores include the earth conductor, whereas 3×0.5 delivers the same three cores with no earth core at all.
Q: What is the minimum bending radius?
A: ROBUST 210: 4 x OD for fixed installation; 15 x OD for occasional flexing. ROBUST 215 C: 6 x OD for fixed installation; 20 x OD for occasional flexing. Confirm the route radius before installation.
Hot Tags: olflex robust 210/215 c control cable, China olflex robust 210/215 c control cable suppliers
Common Specifications - Both Variants
|
Parameter |
Value |
|
Rated Voltage |
300/500 V |
|
Test Voltage |
4000 V (core-to-core) |
|
Conductor |
Class 5 fine-wire bare copper (VDE 0295 / IEC 60228 Class 5) |
|
Insulation |
Modified PP |
|
Sheath |
Special TPE, black (RAL 9005) |
|
Temperature - Fixed Installation |
-50 °C to +80 °C |
|
Temperature - Occasional Flexing |
-40 °C to +80 °C |
|
Core Identification |
Black cores with white sequential numbers (VDE 0293-1) |
|
Protective Conductor |
G = green-yellow earth core included; X = no earth core |
|
Oil Resistance |
EN 50363-4-1 (TM5) - oils, animal/vegetable fats, emulsions, waxes |
|
Ozone / UV / Weather Resistance |
EN 50396 |
|
Freshwater Immersion |
10 m depth, +40 °C water temperature |
|
Chemical Resistance |
Good - ammonia compounds, biogas, coolants, water-soluble cleaners |
|
Min. Bending Radius - Fixed |
4 × OD (ROBUST 210) / 6 × OD (ROBUST 215 C) |
|
Min. Bending Radius - Occasional Flexing |
15 × OD (ROBUST 210) / 20 × OD (ROBUST 215 C) |
Variant Differences
|
Parameter |
ROBUST 210 |
ROBUST 215 C |
|
Core wrap |
None |
Halogen-free plastic foil |
|
Screen |
None |
Tinned-copper braided screen (EMC) |
|
Torsion Rating |
None |
TW-1: >= -20 C, +/-150/m, 2000 cycles; TW-2: >= -40 C, +/-150/m, 2000 cycles |
|
Min. Bending Radius - Fixed |
4 x OD |
6 x OD |
|
Min. Bending Radius - Occasional Flexing |
15 x OD |
20 x OD |
|
Cross-Section Range |
0.5 - 35 mm2 |
0.5 - 35 mm2 |
|
Maximum Cores |
50 |
25 |
Note: torsion ratings TW-1 and TW-2 are available only on ROBUST 215 C. ROBUST 210 is not rated for torsion applications.
AWG Conversion Notice
AWG figures in the tables above are nearest-area equivalents derived from metric cross-sections to IEC 60228, so they are not direct substitutes for AWG-spec cable. For an AWG-dimensioned drawing, our engineers will map each size to the closest metric option available in the ROBUST TPE all-weather construction.
Conversion Reference
0.5→20 / 0.75→18 / 1.0→17 / 1.5→15 / 2.5→13 / 4→11 / 6→9 / 10→7 / 16→5 / 25→3 / 35→2
ROBUST 210 — Part Number Table
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
0021880 |
2 × 0.5 |
20 |
4.9 |
10.0 |
27 |
|
0021881 |
3 G 0.5 |
20 |
5.2 |
15.0 |
33 |
|
0021882 |
3 × 0.5 |
20 |
5.2 |
15.0 |
33 |
|
0021883 |
4 G 0.5 |
20 |
5.8 |
19.2 |
41 |
|
0021884 |
4 × 0.5 |
20 |
5.8 |
19.2 |
41 |
|
0021885 |
5 G 0.5 |
20 |
6.3 |
24.0 |
49 |
|
0021886 |
5 × 0.5 |
20 |
6.3 |
24.0 |
49 |
|
0021888 |
7 G 0.5 |
20 |
6.9 |
33.6 |
64 |
|
0021889 |
7 × 0.5 |
20 |
6.9 |
33.6 |
64 |
|
0021897 |
2 × 0.75 |
18 |
5.5 |
14.4 |
35 |
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
0021898 |
3 G 0.75 |
18 |
5.8 |
21.6 |
43 |
|
0021899 |
3 × 0.75 |
18 |
5.8 |
21.6 |
43 |
|
0021900 |
4 G 0.75 |
18 |
6.3 |
28.8 |
49 |
|
0021901 |
4 × 0.75 |
18 |
6.3 |
28.8 |
49 |
|
0021902 |
5 G 0.75 |
18 |
6.9 |
36.0 |
66 |
|
0021903 |
5 × 0.75 |
18 |
6.9 |
36.0 |
66 |
|
0021904 |
7 G 0.75 |
18 |
7.5 |
50.0 |
85 |
|
0021912 |
50 G 0.75 |
18 |
19.6 |
360.0 |
560 |
|
0021913 |
2 × 1.0 |
17 |
5.8 |
19.2 |
42 |
|
0021914 |
3 G 1.0 |
17 |
6.1 |
28.8 |
49 |
ROBUST 215 C — Part Number Table
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
0022700 |
2 × 0.5 |
20 |
5.9 |
36.0 |
42 |
|
0022701 |
3 G 0.5 |
20 |
6.2 |
43.0 |
52 |
|
0022702 |
3 × 0.5 |
20 |
6.2 |
43.0 |
52 |
|
0022703 |
4 G 0.5 |
20 |
6.6 |
49.0 |
59 |
|
0022704 |
4 × 0.5 |
20 |
6.6 |
49.0 |
59 |
|
0022705 |
5 G 0.5 |
20 |
7.1 |
57.0 |
68 |
|
0022706 |
5 × 0.5 |
20 |
7.1 |
57.0 |
68 |
|
0022717 |
2 × 0.75 |
18 |
6.3 |
43.0 |
50 |
|
0022718 |
3 G 0.75 |
18 |
6.6 |
52.0 |
60 |
|
0022719 |
3 × 0.75 |
18 |
6.6 |
52.0 |
60 |
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
0022720 |
4 G 0.75 |
18 |
7.1 |
61.0 |
72 |
|
0022721 |
4 × 0.75 |
18 |
7.1 |
61.0 |
72 |
|
0022722 |
5 G 0.75 |
18 |
7.9 |
72.0 |
88 |
|
0022723 |
5 × 0.75 |
18 |
7.9 |
72.0 |
88 |
|
0022733 |
2 × 1.0 |
17 |
6.6 |
51.0 |
60 |
|
0022734 |
3 G 1.0 |
17 |
6.9 |
62.0 |
70 |
|
0022735 |
3 × 1.0 |
17 |
6.9 |
62.0 |
70 |
|
0022736 |
4 G 1.0 |
17 |
7.4 |
74.0 |
85 |
|
0022737 |
4 × 1.0 |
17 |
7.4 |
74.0 |
85 |
|
0022738 |