Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex classic 100 300/500v control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Lead Paragraph
OLFLEX CLASSIC 100 300/500V is the general-purpose PVC control cable that carries the largest share of panel and machinery wiring wherever circuit voltages stay inside the 300/500 V band. Two sheath finishes sit on one electrical platform: grey RAL 7001 for standard panel work, and black RAL 9005 where a project specification or a site wiring code asks for a dark jacket. Cores are Class 5 fine-wire bare copper to VDE 0295 / IEC 60228, so the cable stays workable through repeated re-termination in dense terminal rails while still holding its shape along a cable duct. Every production length carries a 4 kV factory dielectric test and the compound self-extinguishes to IEC 60332-1-2.
Choosing Between the Grey and Black Jackets
The two finishes are not different cables - they are the same conductor, insulation and test regime under a different outer compound colour. The choice is driven by drawing discipline and by how many cable groups share one duct.
|
Selection Factor |
Grey RAL 7001 |
Black RAL 9005 (BK) |
|
Nominal voltage |
300/500 V |
300/500 V |
|
Electrical performance |
Identical |
Identical |
|
Cross-section range |
0.5 – 50 mm² |
0.5 – 35 mm² |
|
Core count available |
2 – 25 |
2 – 16 |
|
Part numbers listed |
See Part Numbers section |
See Part Numbers section |
|
Common driver |
Standard panel and machinery wiring practice |
Project spec or wiring code requiring a dark sheath |
Core Identification and Earth-Core Selection in Dense Control Wiring
Most rework in a control cabinet comes from mis-identified cores, not from electrical failure. CLASSIC 100 300/500V is built so that a technician can identify a core by eye without ringing it out first. The rule changes at the five-core boundary: below it, each core carries its own solid colour with green-yellow reserved for the protective earth; from six cores upward, the cable switches to the printed colour code, which runs to 102 combinations drawn from eleven basic colours using single or double rings. Both schemes let a fitter match a core to a terminal schedule at a glance.
|
Core Count Band |
Identification System |
Earth Core |
Practical Effect |
|
2 to 5 cores |
Solid colour per core to VDE 0293-308 |
Green-yellow, on G versions |
Colour alone identifies the function; no code sheet needed |
|
6 cores and above |
Printed colour code (up to 102 combinations, 11 basic colours) |
Green-yellow, on G versions |
A compact code sheet is required at the panel, but core count can rise without diameter penalty |
The G / X decision is a duct-space decision. Choose G when the panel relies on the cable for its protective conductor. Choose X when a separate earth bar or a protective conductor is already routed to the same enclosure - dropping the earth core saves one core's worth of diameter and weight on every run, which matters once several dozen multi-core cables share a tray.
Typical Applications




Why Specify CLASSIC 100 300/500V
Short conductor lay, higher flexibility.
Conductors are fine bare copper strands to VDE 0295 / IEC 60228 Class 5, insulated in PVC to LAPP P8/1. The lay is short, and the short lay is what the range's flexibility rests on: 4 × OD minimum bend radius fixed, 15 × OD for occasional flexing.
01
Torsion-rated for wind turbine crossover runs.
Two torsion classes are available. TW-0 holds 5000 cycles at ± 150° per metre with a +5 °C floor; TW-1 drops to −20 °C and holds 2000 cycles at the same ± 150° per metre. That is the qualification behind WTG crossover wiring.
02
Small outside diameter, more room in the duct.
The construction is kept tight. On a duct already carrying a dozen control runs that is space recovered on every layer, and a smaller gland and punch-out to match.
03
A higher-grade alternative to YSLY or YY control cable.
Where a drawing still calls out YSLY or YY, this is the higher-grade alternative: same 300/500 V band, Class 5 conductor, and the TW-0 / TW-1 torsion classes.
04
Frequently Asked Questions
Q: Is the black (BK) version electrically different from the grey one?
A: No. At the same nominal voltage the two finishes are electrically identical. The black jacket is specified when a project specification or an internal wiring standard calls for a dark outer sheath, usually to separate cable groups visually inside one enclosure.
Q: Can CLASSIC 100 300/500V be used in a drag chain?
A: No. Both jacket finishes are rated for fixed installation and occasional flexing only. Continuous travel in a drag chain needs a cable built for that duty, with a different stranding and sheath system.
Q: What is the difference between G and X in the part number?
A: G includes the green-yellow protective earth core. X omits it, which reduces the core count, the outer diameter and the weight on every run. Choose X only when the protective conductor reaches that enclosure by another route.
Q: Which identification scheme applies to my core count?
A: Up to five cores the cable uses solid core colours to VDE 0293-308. From six cores upward it uses the printed colour code. The boundary is the core count, not the cross-section.
Q: What minimum bend radius applies during installation?
A: 4 × outer diameter for fixed installation and 15 × outer diameter for occasional flexing, measured on the cable centreline. Confirm the tightest corner of the route before pulling the cable into conduit or tray.
Q: Can you supply cut lengths and the earth-core version?
A: Yes - cut lengths are available from factory stock. Minimum cut length and the cutting charge depend on the size; send the size and length and we will quote. G and X are both available up to 1.5 mm²; from 2.5 mm² upward the range is G only.
Hot Tags: olflex classic 100 300/500v control cable, China olflex classic 100 300/500v control cable suppliers
Electrical and Thermal Ratings
|
Parameter |
Rating |
|
Nominal voltage U₀/U |
300/500 V |
|
Factory dielectric test |
4000 V, applied to every production length |
|
Temperature - fixed installation |
−40 °C to +80 °C |
|
Temperature - occasional flexing |
−5 °C to +70 °C |
|
Flame retardancy |
IEC 60332-1-2, single-wire vertical flame test |
|
Design standard |
EN 50525-2-51 |
Construction and Core Identification
|
Layer / Property |
Specification |
|
Conductor |
Class 5 fine-wire bare copper, VDE 0295 / IEC 60228 Class 5 |
|
Insulation |
PVC, colour-coded |
|
Core identification / G–X earth core |
See Overview - Core Identification and Earth-Core Selection |
|
Stranding |
Cores laid up in concentric layers |
|
Outer sheath |
PVC, grey RAL 7001 or black RAL 9005 |
Cabinet Wiring Practice - Bend Radius, Duct Fill and Termination
The minimum bend radius is 4 × outer diameter for fixed installation and 15 × outer diameter for occasional flexing. In a real cabinet the binding constraint is usually the corner where a bundle leaves the duct and turns onto the terminal rail, so the figures below are given for a typical four-core construction where that turn is tightest.
|
Four-Core Size |
Outer Diameter |
Fixed Radius (4 × OD) |
Flexing Radius (15 × OD) |
|
4G0.5 |
5.7 mm |
≈ 23 mm |
≈ 86 mm |
|
4G1.5 |
7.2 mm |
≈ 29 mm |
≈ 108 mm |
|
4G2.5 |
8.9 mm |
≈ 36 mm |
≈ 134 mm |
|
4G6.0 |
13.0 mm |
≈ 52 mm |
≈ 195 mm |
|
4G16.0 |
18.8 mm |
≈ 75 mm |
≈ 282 mm |
|
4G35.0 |
26.4 mm |
≈ 106 mm |
≈ 396 mm |
|
4G50.0 |
32.4 mm |
≈ 130 mm |
≈ 486 mm |
Two further points that decide whether a panel goes together cleanly. First, treat duct fill as a thermal limit as well as a space limit: a duct packed to its geometric maximum has no air path, and the derating matters more than the tidiness. Second, allow the bundle a straight entry length of roughly ten times the outer diameter into the terminal block, so the cores land without side load on the terminals.
Reading the Part Number Tables
AWG figures printed in the tables are nearest-area equivalents converted from the metric cross-section; they are not interchangeable with AWG-specified products. On this page the equivalent column runs from 20 AWG at 0.5 mm² through 13 AWG at 2.5 mm² and 9 AWG at 6 mm², ending at 1/0 at 50 mm². Send the AWG you need and the closest available metric size will be confirmed. In the designation, G means the green-yellow earth core is fitted and X means it is not; 3G0.5 and 3×0.5 both carry three cores.
CLASSIC 100 300/500V, Grey Jacket — Part Number Table
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
00100004 |
2×0.5 |
20 |
4.8 |
9.6 |
35 |
|
00100014 |
3G0.5 |
20 |
5.1 |
14.4 |
42 |
|
00101234 |
4×0.5 |
20 |
5.7 |
19.2 |
54 |
|
0010004 |
6G0.5 |
20 |
6.7 |
28.8 |
73 |
|
0010005 |
7G0.5 |
20 |
6.7 |
33.6 |
81 |
|
0010006 |
8G0.5 |
20 |
8.0 |
38.4 |
97 |
|
0010010 |
16G0.5 |
20 |
10.0 |
76.0 |
169 |
|
0010011 |
21G0.5 |
20 |
11.7 |
99.0 |
223 |
|
0010012 |
24G0.5 |
20 |
12.4 |
114.0 |
254 |
|
00100214 |
2×0.75 |
18 |
5.4 |
14.4 |
45 |
|
00100224 |
3G0.75 |
18 |
5.7 |
21.6 |
55 |
|
00101254 |
3×0.75 |
18 |
5.7 |
21.6 |
55 |
|
0010025 |
6G0.75 |
18 |
7.3 |
43.3 |
104 |
|
0010026 |
7G0.75 |
18 |
7.3 |
50.4 |
109 |
|
0010027 |
8G0.75 |
18 |
8.8 |
56.0 |
123 |
|
0010028 |
9G0.75 |
18 |
9.4 |
63.0 |
144 |
|
0010029 |
10G0.75 |
18 |
9.6 |
72.0 |
153 |
|
0010030 |
12G0.75 |
18 |
9.9 |
86.4 |
176 |
|
0010031 |
15G0.75 |
18 |
10.9 |
108.0 |
211 |
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
0010032 |
18G0.75 |
18 |
11.7 |
129.6 |
268 |
|
0010033 |
21G0.75 |
18 |
13.0 |
151.0 |
293 |
|
0010034 |
25G0.75 |
18 |
13.8 |
180.0 |
374 |
|
00100424 |
3G1.0 |
17 |
6.0 |
28.8 |
65 |
|
0010045 |
6G1.0 |
17 |
8.0 |
58.0 |
124 |
|
0010050 |
12G1.0 |
17 |
10.5 |
115.0 |
215 |
|
0010056 |
25G1.0 |
17 |
14.7 |
240.0 |
449 |
|
00100644 |
3G1.5 |
15 |
6.7 |
43.2 |
84 |
|
00100654 |
4G1.5 |
15 |
7.2 |
57.6 |
104 |
|
1120801 |
3G2.5 |
13 |
8.1 |
72.0 |
132 |
|
1120802 |
4G2.5 |
13 |
8.9 |
96.0 |
163 |
|
1120803 |
5G2.5 |
13 |
10.0 |
120.0 |
200 |
|
1120810 |
3G6.0 |
9 |
11.7 |
174.0 |
289 |
|
1120812 |
5G6.0 |
9 |
14.5 |
288.0 |
470 |
|
1120816 |
5G10.0 |
7 |
18.1 |
480.0 |
722 |
|
1120818 |
4G16.0 |
5 |
18.8 |
614.4 |
1,067 |
|
1120822 |
5G25.0 |
3 |
26.4 |
1,200.0 |
1,998 |
|
1120824 |
4G35.0 |
2 |
26.4 |
1,344.0 |
2,106 |
|
1120826 |
3G50.0 |
1/0 |
29.1 |
1,440.0 |
2,200 |
|
1120828 |
5G50.0 |
1/0 |
36.5 |
2,400.0 |
3,600 |
CLASSIC 100 300/500V BK, Black Jacket — Part Number Table
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
0010421 |
2×0.5 |
20 |
4.8 |
9.6 |
35 |
|
0010133 |
3G0.5 |
20 |
5.1 |
14.4 |
42 |
|
83010350004 |
4G0.5 |
20 |
5.7 |
19.2 |
54 |
|
83010350005 |
5G0.5 |
20 |
6.2 |
24.0 |
63 |
|
83010350007 |
7G0.5 |
20 |
6.7 |
33.6 |
81 |
|
83010350010 |
10G0.5 |
20 |
8.6 |
48.0 |
116 |
|
83010350012 |
12G0.5 |
20 |
8.9 |
58.0 |
133 |
|
83010350016 |
16G0.5 |
20 |
10.0 |
76.0 |
169 |
|
83010352702 |
2×0.75 |
18 |
5.4 |
14.4 |
45 |
|
83010350103 |
3G0.75 |
18 |
5.7 |
21.6 |
55 |
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
83010350104 |
4G0.75 |
18 |
6.2 |
28.8 |
66 |
|
83010350105 |
5G0.75 |
18 |
6.7 |
36.0 |
79 |
|
83010350107 |
7G0.75 |
18 |
7.3 |
50.4 |
109 |
|
83010350112 |
12G0.75 |
18 |
9.9 |
86.4 |
176 |
|
83010353702 |
2×1 |
17 |
5.7 |
19.2 |
53 |
|
83010350203 |
3G1 |
17 |
6.0 |
28.8 |
65 |
|
83010350204 |
4G1 |
17 |
6.5 |
38.4 |
79 |
|
83010350205 |
5G1 |
17 |
7.1 |
48.0 |
94 |
|
83010350207 |
7G1 |
17 |
8.0 |
67.0 |
131 |
|
83010350212 |
12G1 |
17 |
10.5 |
115.0 |
215 |