OLFLEX CLASSIC 100 300/500V Control Cable

OLFLEX CLASSIC 100 300/500V Control Cable
Details:
OLFLEX CLASSIC 100 300/500V PVC control cable in grey or black jacket. Class 5 copper, 4 kV tested, 0.5-50 mm2, 2-25 cores. Cut to length from factory stock.

Standards & Compliance
EN 50525-2-51 | VDE 0295 / IEC 60228 Class 5 | VDE 0293-308 | IEC 60332-1-2

Quick Specs
300/500 V | 4000 V test | 0.5 – 50 mm² (grey) / 0.5 – 35 mm² (BK) | −40 °C to +80 °C fixed | Grey RAL 7001 or black RAL 9005 (BK)
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex classic 100 300/500v control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

OLFLEX CLASSIC 100 300/500V is the general-purpose PVC control cable that carries the largest share of panel and machinery wiring wherever circuit voltages stay inside the 300/500 V band. Two sheath finishes sit on one electrical platform: grey RAL 7001 for standard panel work, and black RAL 9005 where a project specification or a site wiring code asks for a dark jacket. Cores are Class 5 fine-wire bare copper to VDE 0295 / IEC 60228, so the cable stays workable through repeated re-termination in dense terminal rails while still holding its shape along a cable duct. Every production length carries a 4 kV factory dielectric test and the compound self-extinguishes to IEC 60332-1-2.

 

Choosing Between the Grey and Black Jackets

 

The two finishes are not different cables - they are the same conductor, insulation and test regime under a different outer compound colour. The choice is driven by drawing discipline and by how many cable groups share one duct.

 

Selection Factor

Grey RAL 7001

Black RAL 9005 (BK)

Nominal voltage

300/500 V

300/500 V

Electrical performance

Identical

Identical

Cross-section range

0.5 – 50 mm²

0.5 – 35 mm²

Core count available

2 – 25

2 – 16

Part numbers listed

See Part Numbers section

See Part Numbers section

Common driver

Standard panel and machinery wiring practice

Project spec or wiring code requiring a dark sheath

 

Core Identification and Earth-Core Selection in Dense Control Wiring

 

Most rework in a control cabinet comes from mis-identified cores, not from electrical failure. CLASSIC 100 300/500V is built so that a technician can identify a core by eye without ringing it out first. The rule changes at the five-core boundary: below it, each core carries its own solid colour with green-yellow reserved for the protective earth; from six cores upward, the cable switches to the printed colour code, which runs to 102 combinations drawn from eleven basic colours using single or double rings. Both schemes let a fitter match a core to a terminal schedule at a glance.

 

Core Count Band

Identification System

Earth Core

Practical Effect

2 to 5 cores

Solid colour per core to VDE 0293-308

Green-yellow, on G versions

Colour alone identifies the function; no code sheet needed

6 cores and above

Printed colour code (up to 102 combinations, 11 basic colours)

Green-yellow, on G versions

A compact code sheet is required at the panel, but core count can rise without diameter penalty

 

The G / X decision is a duct-space decision. Choose G when the panel relies on the cable for its protective conductor. Choose X when a separate earth bar or a protective conductor is already routed to the same enclosure - dropping the earth core saves one core's worth of diameter and weight on every run, which matters once several dozen multi-core cables share a tray.

 

Typical Applications

 

01machine-tool-internal-wiring-colour-coded-control-interlock-and-indicator-cores-terminated-inside-an-open-panel-on-the-shop-floor

Machine-tool internal wiring.
Carries control, interlock and indicator circuits inside the machine frame, where the core colours must stay readable after the panel has been opened several times.

02control-cabinet-and-distribution-board-assembly-form-wired-panel-with-ferrule-terminated-colour-coded-cores-and-the-wiring-schedule-fixed-inside-the-door

Control cabinet and distribution board assembly.
Form-wired panel builds where a colour-coded, ferrule-terminated core is the fastest way to follow a wiring schedule.

03conveyor-control-wiring-diagram-pedal-switch-push-buttons-3-pole-mcb-contactor-and-overload-relay-feeding-a-conveyor-drive-motor

Conveyor and material-handling control circuits.
Fixed runs along a conveyor frame feeding sensors, contactors and drives at a single voltage grade.

04hvac-and-building-services-control-panel-pump-and-fan-circuits-with-breakers-contactors-controller-and-terminal-blocks-on-din-rail

HVAC and building-services control panels.
Fan, pump and valve control loops inside plant rooms, where a flame-retardant sheath matters as much as flexibility.

 

Why Specify CLASSIC 100 300/500V

 

Short conductor lay, higher flexibility.

Conductors are fine bare copper strands to VDE 0295 / IEC 60228 Class 5, insulated in PVC to LAPP P8/1. The lay is short, and the short lay is what the range's flexibility rests on: 4 × OD minimum bend radius fixed, 15 × OD for occasional flexing.

01

Torsion-rated for wind turbine crossover runs.

Two torsion classes are available. TW-0 holds 5000 cycles at ± 150° per metre with a +5 °C floor; TW-1 drops to −20 °C and holds 2000 cycles at the same ± 150° per metre. That is the qualification behind WTG crossover wiring.

02

Small outside diameter, more room in the duct.

The construction is kept tight. On a duct already carrying a dozen control runs that is space recovered on every layer, and a smaller gland and punch-out to match.

03

A higher-grade alternative to YSLY or YY control cable.

Where a drawing still calls out YSLY or YY, this is the higher-grade alternative: same 300/500 V band, Class 5 conductor, and the TW-0 / TW-1 torsion classes.

04

 

Frequently Asked Questions

 

Q: Is the black (BK) version electrically different from the grey one?

A: No. At the same nominal voltage the two finishes are electrically identical. The black jacket is specified when a project specification or an internal wiring standard calls for a dark outer sheath, usually to separate cable groups visually inside one enclosure.

Q: Can CLASSIC 100 300/500V be used in a drag chain?

A: No. Both jacket finishes are rated for fixed installation and occasional flexing only. Continuous travel in a drag chain needs a cable built for that duty, with a different stranding and sheath system.

Q: What is the difference between G and X in the part number?

A: G includes the green-yellow protective earth core. X omits it, which reduces the core count, the outer diameter and the weight on every run. Choose X only when the protective conductor reaches that enclosure by another route.

Q: Which identification scheme applies to my core count?

A: Up to five cores the cable uses solid core colours to VDE 0293-308. From six cores upward it uses the printed colour code. The boundary is the core count, not the cross-section.

Q: What minimum bend radius applies during installation?

A: 4 × outer diameter for fixed installation and 15 × outer diameter for occasional flexing, measured on the cable centreline. Confirm the tightest corner of the route before pulling the cable into conduit or tray.

Q: Can you supply cut lengths and the earth-core version?

A: Yes - cut lengths are available from factory stock. Minimum cut length and the cutting charge depend on the size; send the size and length and we will quote. G and X are both available up to 1.5 mm²; from 2.5 mm² upward the range is G only.

 

 

Hot Tags: olflex classic 100 300/500v control cable, China olflex classic 100 300/500v control cable suppliers

Electrical and Thermal Ratings

 

Parameter

Rating

Nominal voltage U₀/U

300/500 V

Factory dielectric test

4000 V, applied to every production length

Temperature - fixed installation

−40 °C to +80 °C

Temperature - occasional flexing

−5 °C to +70 °C

Flame retardancy

IEC 60332-1-2, single-wire vertical flame test

Design standard

EN 50525-2-51

 

Construction and Core Identification

 

Layer / Property

Specification

Conductor

Class 5 fine-wire bare copper, VDE 0295 / IEC 60228 Class 5

Insulation

PVC, colour-coded

Core identification / G–X earth core

See Overview - Core Identification and Earth-Core Selection

Stranding

Cores laid up in concentric layers

Outer sheath

PVC, grey RAL 7001 or black RAL 9005

 

Cabinet Wiring Practice - Bend Radius, Duct Fill and Termination

 

The minimum bend radius is 4 × outer diameter for fixed installation and 15 × outer diameter for occasional flexing. In a real cabinet the binding constraint is usually the corner where a bundle leaves the duct and turns onto the terminal rail, so the figures below are given for a typical four-core construction where that turn is tightest.

 

Four-Core Size

Outer Diameter

Fixed Radius (4 × OD)

Flexing Radius (15 × OD)

4G0.5

5.7 mm

≈ 23 mm

≈ 86 mm

4G1.5

7.2 mm

≈ 29 mm

≈ 108 mm

4G2.5

8.9 mm

≈ 36 mm

≈ 134 mm

4G6.0

13.0 mm

≈ 52 mm

≈ 195 mm

4G16.0

18.8 mm

≈ 75 mm

≈ 282 mm

4G35.0

26.4 mm

≈ 106 mm

≈ 396 mm

4G50.0

32.4 mm

≈ 130 mm

≈ 486 mm

 

Two further points that decide whether a panel goes together cleanly. First, treat duct fill as a thermal limit as well as a space limit: a duct packed to its geometric maximum has no air path, and the derating matters more than the tidiness. Second, allow the bundle a straight entry length of roughly ten times the outer diameter into the terminal block, so the cores land without side load on the terminals.

 

Reading the Part Number Tables

 

AWG figures printed in the tables are nearest-area equivalents converted from the metric cross-section; they are not interchangeable with AWG-specified products. On this page the equivalent column runs from 20 AWG at 0.5 mm² through 13 AWG at 2.5 mm² and 9 AWG at 6 mm², ending at 1/0 at 50 mm². Send the AWG you need and the closest available metric size will be confirmed. In the designation, G means the green-yellow earth core is fitted and X means it is not; 3G0.5 and 3×0.5 both carry three cores.

 

CLASSIC 100 300/500V, Grey Jacket — Part Number Table

 

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

00100004

2×0.5

20

4.8

9.6

35

00100014

3G0.5

20

5.1

14.4

42

00101234

4×0.5

20

5.7

19.2

54

0010004

6G0.5

20

6.7

28.8

73

0010005

7G0.5

20

6.7

33.6

81

0010006

8G0.5

20

8.0

38.4

97

0010010

16G0.5

20

10.0

76.0

169

0010011

21G0.5

20

11.7

99.0

223

0010012

24G0.5

20

12.4

114.0

254

00100214

2×0.75

18

5.4

14.4

45

00100224

3G0.75

18

5.7

21.6

55

00101254

3×0.75

18

5.7

21.6

55

0010025

6G0.75

18

7.3

43.3

104

0010026

7G0.75

18

7.3

50.4

109

0010027

8G0.75

18

8.8

56.0

123

0010028

9G0.75

18

9.4

63.0

144

0010029

10G0.75

18

9.6

72.0

153

0010030

12G0.75

18

9.9

86.4

176

0010031

15G0.75

18

10.9

108.0

211

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

0010032

18G0.75

18

11.7

129.6

268

0010033

21G0.75

18

13.0

151.0

293

0010034

25G0.75

18

13.8

180.0

374

00100424

3G1.0

17

6.0

28.8

65

0010045

6G1.0

17

8.0

58.0

124

0010050

12G1.0

17

10.5

115.0

215

0010056

25G1.0

17

14.7

240.0

449

00100644

3G1.5

15

6.7

43.2

84

00100654

4G1.5

15

7.2

57.6

104

1120801

3G2.5

13

8.1

72.0

132

1120802

4G2.5

13

8.9

96.0

163

1120803

5G2.5

13

10.0

120.0

200

1120810

3G6.0

9

11.7

174.0

289

1120812

5G6.0

9

14.5

288.0

470

1120816

5G10.0

7

18.1

480.0

722

1120818

4G16.0

5

18.8

614.4

1,067

1120822

5G25.0

3

26.4

1,200.0

1,998

1120824

4G35.0

2

26.4

1,344.0

2,106

1120826

3G50.0

1/0

29.1

1,440.0

2,200

1120828

5G50.0

1/0

36.5

2,400.0

3,600

 

CLASSIC 100 300/500V BK, Black Jacket — Part Number Table

 

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

0010421

2×0.5

20

4.8

9.6

35

0010133

3G0.5

20

5.1

14.4

42

83010350004

4G0.5

20

5.7

19.2

54

83010350005

5G0.5

20

6.2

24.0

63

83010350007

7G0.5

20

6.7

33.6

81

83010350010

10G0.5

20

8.6

48.0

116

83010350012

12G0.5

20

8.9

58.0

133

83010350016

16G0.5

20

10.0

76.0

169

83010352702

2×0.75

18

5.4

14.4

45

83010350103

3G0.75

18

5.7

21.6

55

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

83010350104

4G0.75

18

6.2

28.8

66

83010350105

5G0.75

18

6.7

36.0

79

83010350107

7G0.75

18

7.3

50.4

109

83010350112

12G0.75

18

9.9

86.4

176

83010353702

2×1

17

5.7

19.2

53

83010350203

3G1

17

6.0

28.8

65

83010350204

4G1

17

6.5

38.4

79

83010350205

5G1

17

7.1

48.0

94

83010350207

7G1

17

8.0

67.0

131

83010350212

12G1

17

10.5

115.0

215

 

Send Inquiry