Robotics & Motion Systems

Robotics & Motion Systems Cables & Assemblies

A robot or a multi-axis machine loads its cables in more than one way. The fixed base and cabinet carry stationary wiring, a linear axis bends cable in a carrier, and a robot wrist twists cable around its own axis. Feedback and network links must also suit the motion they follow. KABASI supplies industrial cable and builds assemblies and harnesses to drawing for robot cells, gantries and motion platforms.

Start with the motion zone. Then confirm the electrical function, the fixed-to-moving boundary, the protocol and what the drawing already defines.

roboticsrepeatedmotioncobotendeffectorwiring

Motion Zone Architecture: From Fixed Base to Moving Axis

Start at the cabinet and trace the cable to the moving equipment. Each segment can carry the same circuit while seeing a different mechanical load.

Fixed zone · 01 Cabinet and base
Moving zone · 02 Linear travel · 03 Joint torsion · 04 Moving links
roboticsrepeatedmotionrobotarmcableroutingworkshop
roboticsrepeatedmotionassemblyrobotinternalcabling

Cable construction reference

Zone 1

Fixed Base and Control Cabinet

Cabinet interiors, base frames, fixed trunking and cable runs that stay in place after installation. Set the panel wire standard and establish the fixed run length here.

Decides
Panel wire standard, conductor count, shielding and cabinet-to-base routing.

roboticsrepeatedmotionlinearmodularrobotenergychain

Cable construction reference

Zone 2

Linear Travel in a Cable Carrier

Gantries, slides, lifts and traversing units repeatedly guide cable through a bend in one plane. The carrier geometry sets the bend along the axis travel.

Decides
Continuous or intermittent travel, carrier radius, travel length, acceleration and jacket requirements.

Current Product Examples
TRVV · TRVU · MULTIFLEX 512 PUR · OLFLEX CLASSIC FD 810

olflex-robot-915-robotic-torsion-cable

Cable construction reference

Zone 3

Rotary and Torsion at the Joint

At a wrist, rotating column or indexing head, joint motion can twist the cable around its own axis. The cable may bend as it follows the joint.

Decides
Joint rotation range, torsion, combined bending and support along the joint.

Current Product Examples
OLFLEX ROBOT 915

industrialautomationvalveislandestopbuttonstationwiring

Cable construction reference

Zone 4

Feedback and Network Links That Follow the Axis

Position feedback, drive commands and network links may terminate on moving equipment. Match the moving segment to the axis it follows as well as to its electrical function.

Decides
Protocol, signal type, shielding, which segment moves and termination at the moving end.

Mark the fixed-to-moving boundary on the drawing. Where the project calls for a change in cable construction, locate the transition at the boundary and keep the moving run continuous.

Where the Fixed Zone Ends and the Moving Zone Begins

Define the boundary at the first point where the cable starts to move with the axis. Specify cable construction on each side using the actual installation and motion.

Locate the First Point of Motion

Use the point where the cable first moves with the axis. A run may leave the cabinet, pass through a gland and cross a fixed frame before entering the carrier. Check the fixed and moving segments separately.

Locate the Transition Outside the Travel

Where two cable constructions are needed, locate the change at the boundary. Keep splices and changes in stiffness out of the portion that travels so the cable can bend consistently along its guided path.

Show the Anchor and Free Travel

Mark the fixed-side anchor, the free length needed through the full travel and the strain-relief positions. Set the restraint and clearance from the machine and carrier drawings so the run moves without loading the terminations.

Dimension the Boundary on the Drawing

Record the carrier entry, the boundary location and the fixed and moving lengths using a shared reference. Use those dimensions when defining a finished assembly or harness.

Five Checks Before Releasing the Drawing

  1. Which axis does the cable follow, and where does the cable start to move?
  2. Does it bend in one plane, twist around its axis or do both?
  3. Where are the anchors, and how much free length does the route need?
  4. Does a feedback or network link cross the same boundary, and does its cable suit the same motion?
  5. Which panel wire standard applies on the fixed side?

Fixed length → First point of motion → Moving length

Anchor point · Carrier entry · Free length through travel

Industrial test equipment and a mechanical fixture in the KABASI laboratory

Bending, Torsion or Occasional Flex: Selecting by Motion Duty

Use the motion duty to narrow down the cable construction, then confirm the electrical ratings. A gantry carrier, a robot wrist and an indexing axis each place different loads on the cable.

05multiflex-512-pur-drag-chain-cable-card-grey-pur-jacket-with-the-printed-legend-and-numbered-cores-at-the-stripped-end

Cable construction reference

Continuous Bending in a Cable Carrier

The carrier guides the cable through the same plane of bending on each pass. Select the cable for the full stroke and the carrier layout.

Confirm
Continuous or intermittent travel, carrier radius, travel length, acceleration and exposure to oil, chips or coolant.

Current Product Examples
TRVU, highly flexible drag chain cable · MULTIFLEX 512 PUR, continuous-flex cable with PUR jacket · OLFLEX CLASSIC FD 810, continuous-flex cable for carriers.

TRVV in intermittent travel
TRVV covers moderate-flex duty for repeated, intermittent movement. Check the product documentation against the actual duty.

Unshielded R-FLEX robot cable cutaway and conductor cross-section

Cable construction reference

Torsion at a Robot Joint

A robot joint can twist the cable along its own axis as it turns and reverses. Check the twist over the actual routed length, including any bending the cable sees at the wrist.

Confirm
Torsion range, joint speed, combined bending, wrist clearance and cable support.

Current Product Examples
OLFLEX ROBOT 915, robot cable for torsion at joints.

01helukabel-jz-hf-drag-chain-cable-card-grey-pur-jacket-printed-jz-hf-numbered-black-cores-green-yellow-earth-core-and-tinned-copper-braid

Cable construction reference

Occasional Flex During Positioning

An indexing or positioning axis may move at intervals and stay in place between moves. Confirm how often it moves and the smallest bend in the installed route.

Confirm
Moves per shift, minimum installed radius, use of a carrier and anchoring on the fixed side.

Current Product Examples
TRVV, moderate-flex drag chain cable · JZ-HF, flexible control cable for moving machine parts.

Motion Duty What the Cable Sees Current Product Examples Check Separately
Continuous bending Repeated single-plane bending in a carrier TRVU · MULTIFLEX 512 PUR · OLFLEX CLASSIC FD 810 Torsion if the route enters a wrist
Torsion Twist around the cable axis, often reversing OLFLEX ROBOT 915 Repeated bending if the route enters a carrier
Occasional flex Intermittent positioning with periods at rest TRVV · JZ-HF Continuous carrier duty if the cycle changes

Cable Supply, Point-to-Point Assembly or Multi-Branch Harness

Choose the delivery route from what the drawing already defines. Specify the base cable for in-house termination, two endpoints for a finished assembly, or the full branch layout for a harness.

Coiled industrial cable with exposed insulated conductors

Industrial Cable Supply

For integrators and robot builders who cut, strip and terminate in-house.

Robotics and Motion Scenario
A series-built robot cell or gantry where the customer's workshop prepares the moving runs from reels.

Green point-to-point cable assemblies with circular and RJ45 connector ends

Point-to-Point Cable Assembly

One finished connection with two defined ends, a pinout and a finished length. Dimension the fixed-to-moving boundary so both sections use the same reference.

Robotics and Motion Scenario
Cabinet to moving carriage, drive to gantry motor, robot base to the first fixed point, or cabinet to a moving station.

Y-branch cable harness with three circular connector ends

Multi-Branch Wire Harness

A finished route to several devices, with the breakout points, branch lengths, connection matrix and identification defined in the drawing.

Robotics and Motion Scenario
A carrier run breaking out to several devices on a carriage, a harness split at a fixed base and moving frame, or a cabinet harness feeding multiple drives.

Decision Point Cable Supply Point-to-Point Assembly Multi-Branch Harness
Who cuts and terminates Customer KABASI KABASI
What the drawing defines Cable construction and reel length Two ends, boundary, length and pinout Connection matrix, branches, marking and split location
Where it fits Cable material for any zone One link across a boundary or to one device Several devices on one carriage or a route split between fixed and moving sections
What a routing change affects The customer adjusts the route Finished length, boundary location or pinout Branch geometry, breakout locations or connection matrix
Boundary treatment The customer sets the transition The boundary dimension is recorded with the finished length The specified split is built into the harness

Information to Confirm for a Robotics or Motion Cable Project

Project Information to Include with Your Drawing or BOM
Axis and zone
Which axis the cable follows and which motion zone it sits in.
Motion duty
Continuous bending, torsion, occasional flex or fixed installation.
Geometry
Travel, carrier radius, torsion range and the fixed-to-moving boundary location.
Dynamics
Axis speed, acceleration and whether the movement reverses.
Electrical function
Drive power, feedback, control, signal or communication.
Electrical ratings
Voltage, current, conductor size and number of cores or pairs.
Communication
CAN Bus, CC-Link, DeviceNet, PROFIBUS, RS485, PROFINET or EtherCAT.
Environment
Temperature, oil, coolant, chips, moisture and jacket requirements.
Fixed-side standard
UL Style, European harmonized designation or customer panel standard. See Control Cables for the fixed control route.
Finished connection
Connector and terminal details, pinout, branch layout and finished length.
Documentation
Specified brand and product family, markings and required product documents.

Is a Cable Brand Fixed in the Robot Specification?

If the robot specification, integrator BOM or maintenance list names a cable brand or series, confirm the exact type and its documentation. KABASI supplies customer-specified branded cable from the named manufacturer.

Robotics and Motion Cable FAQs

Can a drag chain cable be used on a robot joint?

If the joint twists the cable around its own axis, use a cable documented for that torsion. A drag chain cable is selected for repeated bending in a carrier. For a small joint movement with a guided route, verify the load the cable actually sees.

Where exactly should the fixed zone end on a moving axis?

The fixed zone ends at the first point where the cable starts moving with the axis. A cabinet exit or gland can be upstream of that point. Dimension the boundary on the drawing and use the same reference for the fixed and moving lengths.

Does the right conductor count make a cable suitable for a moving axis?

Conductor count and size address the electrical requirements. Confirm the cable construction and documented suitability for the actual bending or torsion before selecting it for a moving axis.

How is a network link handled when it has to follow an axis?

Confirm the protocol and identify which portion of the link moves. Then verify that the exact cable meets the electrical requirements and is documented for that installation and motion.

Is a servo cable suitable for continuous travel in a carrier?

Check the exact servo cable's documented carrier suitability alongside its voltage, conductor size and shielding. If the route enters a joint, confirm the required torsion duty as well.

What if one axis both bends and twists?

Record both loads on the route and check them together. Look at where the cable bends, over what length it twists, and whether the loads occur at the same time. Where the selected cable lacks documented suitability for both, review whether the route can separate the bending and torsion zones.

Send the Axis Data and the Drawing

Send your drawing or BOM with the axis name, motion duty, travel or torsion range, fixed-to-moving boundary, electrical function and communication protocol. For an assembly or harness, add the connection list and show where the fixed and moving sections separate. KABASI can review the cable category and whether to supply cable or a finished connection.

Related industries · Industrial Automation · Machine Building