Lapp LiY Flexible Stranded Hook-Up Wire

Lapp LiY Flexible Stranded Hook-Up Wire
Details:
LiY flexible stranded PVC hook-up single-core wire: compliant with VDE 0812 & VDE 0207-4, fine bare copper stranding (0.14 & 0.25 mm² / 26 & 24 AWG), 13 distinct color codings, cost-effective internal wiring for telecommunications and control electronics.

Standards & Compliance
VDE 0812 (Telecommunication Wires) | VDE 0207-4 (Insulation Type YI 2 / TI 2) | IEC 60332-1-2 Flame Retardant

Quick Specs
Rated voltage < 50 V AC / 75 V DC | 1200 V (0.14 mm²) / 2500 V (0.25 mm²) test | 0.14 – 0.25 mm² single-core | −30 °C to +70 °C fixed | 13 colors to DIN 47100
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of lapp liy flexible stranded hook-up wire in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

LiY is the finely stranded single-core wire for wiring inside telecommunications equipment and electronic sub-assemblies, and for the signal side of a switchgear cabinet. It is made to VDE 0812: 0.14 mm² with at least 18 strands of 0.10 mm, 0.25 mm² with at least 14 strands of 0.15 mm, insulated with PVC type YI 2 / TI 2 to VDE 0207-4. Overall diameter is 1.1 mm and 1.3 mm, which is what lets a dense terminal block take the next wire. Thirteen colours; 0.14 mm² on 500 m spools, 0.25 mm² on 250 m spools, both from stock.

 

LiY at a Glance

 

Two conductor sizes, thirteen colours each - the only choice to make is the size and the colour.

 

Section / AWG

Stranding

Outer Diameter

Peak Voltage

Spool Packaging

Available Colors

0.14 mm² / 26 AWG

≥ 18 × 0.10 mm Ø

1.1 mm

500 V

500 m / spool

13 colors (Black, Blue, Brown, Red, White, Grey, Violet, Pink, Orange, Yellow, Green, Dark Blue, Green-Yellow)

0.25 mm² / 24 AWG

≥ 14 × 0.15 mm Ø

1.3 mm

900 V

250 m / spool

13 colors (Black, Blue, Brown, Red, White, Grey, Violet, Pink, Orange, Yellow, Green, Dark Blue, Green-Yellow)

 

Typical Applications

 

 

 

LiY is primarily applied for point-to-point internal signal jumping, PCB harness termination, and telecommunications switching connections across control cabinet doors, relay sockets, and precision diagnostic devices where space is strictly limited.

01point-to-point-signal-jumping-inside-a-control-cabinet-ferruled-cores-on-pcb-terminal-strips-and-relay-sockets-mounted-on-the-door
 
 

Why Choose LiY Hook-Up Wire Series

 

Advantage

What it means on site

1.1 mm and 1.3 mm Overall Diameter The same conductor size in a smaller overall diameter - which is the whole difference in a full terminal block or a narrow duct.
Finely Stranded for Repeated Flexing At least 18 strands at 0.14 mm² and at least 14 at 0.25 mm², which is what a wire needs where it is handled and re-dressed rather than clamped once.
Thirteen Colours Black, blue, brown, red, white, grey, violet, pink, orange, yellow, green, dark blue and green-yellow - enough to keep a signal circuit identifiable end to end.

 

LiY and H05V-K: Signal Wire Against Panel Power Wire

 

LiY is dedicated to low-voltage electronic signal logic, strictly segregated from mains panel power conductors:

 

Dimension

LiY Electronic Hook-Up Wire (VDE 0812)

H05V-K / H07V-K Cabinet Power Wire (EN 50525-2-31)

Engineering Value of Distinction

Standards & Voltage

VDE 0812; operating voltage < 50 V AC (UPP ≤ 250 V)

EN 50525-2-31; rated 300/500 V or 450/750 V AC

LiY is optimized for low-voltage signal logic; H05/H07 are governed by mains power installation codes.

Profile & Bundle Size

Overall diameter 1.1 mm at 0.14 mm² and 1.3 mm at 0.25 mm² Thicker wall for 300/500 V and 450/750 V service Same conductor size in a smaller diameter - that is the whole difference in a full terminal block.

Conductor Stranding

Micro-fine strands (0.10–0.15 mm single wire diameter)

Fine-stranded Class 5 copper Stranded for the places where the wire is dressed and re-dressed rather than clamped once.

 

Frequently Asked Questions

 

Q: What is the fundamental difference between LiY wire and standard H05V-K panel wire?

A: LiY is governed by VDE 0812 specifically as an electronic hook-up wire for low-voltage signal, telecommunications, and instrumentation circuits (< 50V AC). It features ultra-fine copper strands and a thin-wall PVC jacket (OD 1.1–1.3 mm). H05V-K is governed by mains power installation standards (VDE 0281 / EN 50525-2-31) with a thicker insulation wall designed for 300/500 V power distribution.

Q: Can LiY hook-up wire be used for 230 V AC mains control wiring?

A: No. LiY is rated for an operating voltage below 50 V AC, with a peak voltage of 250 V; the 500 V and 900 V figures are peak working voltages, not a mains rating. For 230 V control wiring the wire has to be an H05V-K (300/500 V) or H07V-K (450/750 V) type.

Q: Why are LiY conductors stranded rather than solid copper cores?

A: Stranded copper conductors (at least 18 strands for 0.14 mm², at least 14 for 0.25 mm²) provide exceptional mechanical flexibility. Solid single-core wires work-harden and snap under vibration or during cabinet door opening cycles. Stranded LiY absorbs flexing and ensures reliable crimping into miniature terminal pins.

 

 

Hot Tags: lapp liy flexible stranded hook-up wire, China lapp liy flexible stranded hook-up wire suppliers

Technical Parameter

Standard Reference & Certified Value

Conductor Construction

Fine bare copper strands: 0.14 mm² ≥ 18 × 0.10 mm Ø | 0.25 mm² ≥ 14 × 0.15 mm Ø (VDE 0812)

Insulation Material

lSpecial PVC compound Type YI 2 / TI 2, to VDE 0207-4

Operating / Peak Voltage

Operating voltage < 50 V AC (UPP ≤ 250 V); Peak voltage: 500 V (0.14 mm²) | 900 V (0.25 mm²)

Dielectric Test Voltage

1200 V AC (0.14 mm²) | 2500 V AC (0.25 mm²)

Outer Diameter (Nominal)

0.14 mm²: 1.1 mm | 0.25 mm²: 1.3 mm

Temperature Range (Fixed)

−30 °C to +70 °C

Flame Retardance

IEC 60332-1-2 single-conductor vertical burn test compliant

Spool Dimensions

Spool 1: d1 = 18 mm, d2 = 150 mm, b = 85 mm · Spool 2: d1 = 40 mm, d2 = 300 mm, b = 112 mm

 

LiY — Part Number Directory

 

Flexible stranded hook-up wire for electronic devices and telecommunications (VDE 0812). Complete catalogue listing covering all 13 colors across 0.14 mm² (500m spools) and 0.25 mm² (250m spools) with integrated AWG column.

 

Part No.

Cross-Section

AWG

Color Designation

Outer Dia. (mm)

Spool Length

Copper (kg/km)

4125001S

0.14 mm²

26 AWG

Black

1.1

500 m

1.35

4125002S

0.14 mm²

26 AWG

Blue

1.1

500 m

1.35

4125003S

0.14 mm²

26 AWG

Brown

1.1

500 m

1.35

4125104S

0.14 mm²

26 AWG

Red

1.1

500 m

1.35

4125105S

0.14 mm²

26 AWG

White

1.1

500 m

1.35

4125106S

0.14 mm²

26 AWG

Grey

1.1

500 m

1.35

4125007S

0.14 mm²

26 AWG

Violet

1.1

500 m

1.35

4125008S

0.14 mm²

26 AWG

Pink

1.1

500 m

1.35

4125009S

0.14 mm²

26 AWG

Orange

1.1

500 m

1.35

4125005S

0.14 mm²

26 AWG

Yellow

1.1

500 m

1.35

4125006S

0.14 mm²

26 AWG

Green

1.1

500 m

1.35

4125014S

0.14 mm²

26 AWG

Dark Blue

1.1

500 m

1.35

4125000S

0.14 mm²

26 AWG

Green-Yellow

1.1

500 m

1.35

Part No.

Cross-Section

AWG

Color Designation

Outer Dia. (mm)

Spool Length

Copper (kg/km)

4126001S

0.25 mm²

24 AWG

Black

1.3

250 m

2.40

4126002S

0.25 mm²

24 AWG

Blue

1.3

250 m

2.40

4126003S

0.25 mm²

24 AWG

Brown

1.3

250 m

2.40

4126104S

0.25 mm²

24 AWG

Red

1.3

250 m

2.40

4126105S

0.25 mm²

24 AWG

White

1.3

250 m

2.40

4126106S

0.25 mm²

24 AWG

Grey

1.3

250 m

2.40

4126007S

0.25 mm²

24 AWG

Violet

1.3

250 m

2.40

4126008S

0.25 mm²

24 AWG

Pink

1.3

250 m

2.40

4126009S

0.25 mm²

24 AWG

Orange

1.3

250 m

2.40

4126005S

0.25 mm²

24 AWG

Yellow

1.3

250 m

2.40

4126006S

0.25 mm²

24 AWG

Green

1.3

250 m

2.40

4126014S

0.25 mm²

24 AWG

Dark Blue

1.3

250 m

2.40

4126000S

0.25 mm²

24 AWG

Green-Yellow

1.3

250 m

2.40

 

Send Inquiry