OLFLEX CLASSIC FD 810 Drag Chain Cable

OLFLEX CLASSIC FD 810 Drag Chain Cable
Details:
OLFLEX CLASSIC FD 810 drag chain control cable: Class 6 copper, PVC sheath, 7.5 × OD moving radius, 20 m travel at 10 m/s and 20 m/s², up to 7 million cycles. Shielded version is FD 810 CP.

Standards & Compliance
VDE 0245 / 0285 | VDE 0295 / IEC 60228 Class 6 | VDE 0293-1 | IEC 60332-1-2 | ETIM EC000104

Quick Specs
300/500 V | 4000 V test | 0.5-16 mm², 2-65 cores | 7.5 × OD moving | 0 to +70 °C moving / −40 to +80 °C fixed
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex classic fd 810 drag chain cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

OLFLEX CLASSIC FD 810 is the drag-chain control cable family for machine axes that keep moving: extra-fine Class 6 stranded copper, cores at a short pitch, and a 7.5 × OD moving bend radius against 4 × OD fixed. It spans 2–65 cores over 0.5 to 16 mm² at 300/500 V in four versions that differ on two axes, sheath material and screening. PVC suits cleanrooms and dry-to-damp interiors; PUR suits machine tools, conveyor wet areas and coolant, lowering the moving temperature floor to −5 °C. Shielded versions add a PVC inner sheath and tinned copper braid for control circuits sharing a duct with drives. FD 810 and FD 810 CP are the main offer, CY and P alongside; all four can be cut, terminated and tested before shipping.

 

Select Your Variant

 

The Four Versions Side by Side

Parameter

FD 810 (main)

FD 810 CP (main)

FD 810 CY (comparison)

FD 810 P (comparison)

Outer sheath

PVC, grey ≈ RAL 7001

PUR, grey ≈ RAL 7001

PVC, grey ≈ RAL 7001

PUR, grey ≈ RAL 7001

Inner sheath

None

PVC

PVC

None

Screening

None

Tinned copper braid

Tinned copper braid

None

Moving temp. floor

0 °C

−5 °C

0 °C

−5 °C

Chemical / abrasion

Standard PVC

PUR: mineral oil, dilute acids/alkalis

Standard PVC

PUR: as CP

Cleanroom listed

Yes - low particle generation

No

No

No

Running envelope

20 m / 20 m/s² / 10 m/s / 7M cycles

50 m / 30 m/s² / 10 m/s / 7M cycles

20 m / 20 m/s² / 10 m/s / 7M cycles

50 m / 30 m/s² / 10 m/s / 7M cycles

 

By Application

Requirement

Choose

Why

Moving axis in dry or damp production hall, standard mechanical load

CLASSIC FD 810 - main offer

PVC sheath, 7.5 × OD moving; low particle generation is named as an advantage

Same axis, wet area with coolant, chips or mineral-oil lubricant

FD 810 P, or FD 810 CP if screening is also needed

PUR sheath resists mineral-oil lubricants, dilute acids and alkalis

Control or measurement cores running beside drives and inverters

FD 810 CY or FD 810 CP

Both add PVC inner sheath and tinned copper braid; pick sheath by environment

Cleanroom or particle-sensitive enclosure

CLASSIC FD 810 - main offer

Only version listed for cleanroom application and low particle generation

Static installation with no movement

Consider an unshielded standard control cable first

7.5 × OD moving radius and Class 6 conductor are paid for whether the cable moves or not

 

Selection Steps

 

Drag-chain cable selection is driven by axis data, not just core count. Collect these figures before choosing a version.

 

COLLECT AXIS DATA

Note the travel distance (m), peak acceleration (m/s²), peak speed (m/s) and estimated lifetime cycle count. These four numbers determine which version of the FD 810 is rated to 20 m / 20 m/s² / 10 m/s; CP extends to 50 m / 30 m/s². For CY and P, refer to appendix A2-1 or send the numbers and we will confirm.

01

ENVIRONMENT

Is the axis in a dry hall, or does it see coolant, chips or chemical splash? Dry or damp, standard mechanical load: choose PVC sheath (FD 810 or CY). Machine tool wet area, conveyor with lubricant: choose PUR sheath (P or CP). PUR also extends the moving temperature floor from 0 °C to −5 °C.

02

EMC

Does the cable share a tray or chain enclosure with variable-frequency drives, soft starters or other switching power devices? If yes, a shielded version (CY or CP) is needed. The braid in CY and CP sits over a PVC inner sheath - the inner sheath stabilises the braid geometry during continuous flexing.

03

PARTICLE SENSITIVITY

Is the axis inside a cleanroom or particle-sensitive enclosure (semiconductor, optics, medical device production)? FD 810 is the only version listed for cleanroom application and low particle generation. PUR-sheathed versions are not listed for this application.

04

CORE COUNT AND CROSS-SECTION

Once the version is confirmed, select core count and cross-section from the part number tables in section 8. FD 810 covers 2 to 65 cores and 0.5 to 16 mm²; CP stops at 25 cores. G rows include a green-yellow protective earth core; X rows do not.

05

 

Send us the five data points above - axis travel, acceleration, speed, cycles and environment - and we will name the version, the core count and the cross-section that cover the application in one reply.

 

Typical Applications

 

01power-chain-and-moving-machine-parts-black-cable-carrier-link-resting-on-a-light-floor-shown-as-a-product-detail-view

Power chains and moving machine parts
Rated to 7.5 × OD while moving against 4 × OD fixed, with Class 6 strands laid up at a short pitch. At 20 m travel, 20 m/s² and 10 m/s the chain life is quoted up to 7 million bending cycles.

02cleanroom-and-particle-sensitive-areas-sealed-corridor-with-blue-lit-process-tools-and-a-polished-floor-in-a-cleanroom

Cleanroom and particle-sensitive areas
The one version listed for cleanroom use, and the reason is wear debris: even inside a moving chain it is credited with very low particle generation. In a wafer or optics enclosure that is the property being bought, not ampacity.

03assembly-and-production-lines-roller-conveyor-and-pallet-handling-stations-framed-in-aluminium-profile-in-an-assembly-hall

Assembly and production lines
Built for assembly and production equipment, where a chain axis repeats the same short move for the life of the line. Travel, acceleration and speed are all quoted, so the axis can be checked against 20 m, 20 m/s² and 10 m/s before the order goes in.

04measurement-and-control-circuits-blue-cores-with-printed-number-sleeves-landed-on-grey-terminal-blocks

Measurement and control circuits
Used for measurement, control and regulation circuits, and available with or without a green-yellow protective core. Unshielded, it suits loops routed clear of drives; where a tray is shared with a converter, specify the braided CY or CP instead.

 

Why Choose OLFLEX CLASSIC FD 810

 

Advantage

What it means on site

A Bend Radius of 7.5 × OD While Moving Is What Buys the Cycles

Fine Class 6 strands, a short lay-up pitch and 7.5 × OD moving against 4 × OD fixed are the three figures that decide chain life. The best case is up to 7 million bending cycles; the same construction used as a static cable wastes that margin, and a static cable used in a chain will not reach it.

Low Particle Generation, Which Is Why Cleanrooms Appear on This Page

Cleanroom application is listed for FD 810, with low particle generation named as an advantage even inside a moving chain. For an enclosure where debris on a wafer or an optic is the real cost, that is the property being purchased - not the ampacity.

PUR Where Coolant Flows, PVC Where It Does Not

PUR versions resist mineral-oil lubricants, dilute acids and alkalis, and take the moving temperature floor to −5 °C; PVC versions stop at 0 °C and are the cheaper answer where the environment is dry or only damp. Machine tool and conveyor wet areas are named for PUR, not for PVC.

A Braid for the Axis That Shares a Duct With a Drive

CY and CP add a PVC inner sheath and a tinned copper braid over the same core construction, which is what a control loop needs when its cable tray is shared with a frequency converter. The inner sheath stabilises the braid geometry during continuous flexing, which is why the shielded versions are wider on the same core count.

 

Frequently Asked Questions

 

Q: What actually changes between the PVC and the PUR versions?

A: Three things, and the rest is common. Moving temperature floor: 0 °C on PVC, −5 °C on PUR.Chemical and abrasion resistance: standard PVC sheath versus a sheath rated for mineral-oil lubricants, dilute acids and alkalis. Outer diameter: the PUR versions are slightly larger for the same core count because the compound behaves differently in extrusion.

Q: What motion envelope is this family rated for?

A: 7.5 × OD moving bend radius for all four versions, against 4 × OD fixed. For running figures: FD 810 is listed at 20 m travel, 20 m/s² and 10 m/s; CP at 50 m, 30 m/s² and 10 m/s, both to 7 million cycles. CY and P reference appendix A2-1. Send the travel, speed and cycle count and we will confirm which version covers the application.

Q: Why is the moving bend radius larger than the fixed one?

A: Different failure modes. A fixed bend of 4 × OD has to survive once at installation. A moving bend of 7.5 × OD has to keep every fine strand inside its elastic range through millions of cycles, which is why the figure is larger and why the Class 6 conductor exists. The bend at the chain entry, not the mid-run radius, is the one that determines chain life - check that point before ordering.

Q: Do I need the shielded version?

A: That depends on what shares the containment. A control or measurement loop whose cable travels beside a frequency converter output or on the same tray as drives is the case CY and CP are built for. Where the loop is segregated from power, the unshielded versions are lighter, narrower and less expensive for the same core count.

Q: Why do two versions have running figures and the other two not?

A: FD 810 is rated 20 m / 20 m/s² / 10 m/s and CP 50 m / 30 m/s² / 10 m/s, both to 7 million cycles. For the version and cross-section you are considering, send the travel, speed and cycle count and we will confirm the figure with the quotation.

 

 

Hot Tags: olflex classic fd 810 drag chain cable, China olflex classic fd 810 drag chain cable suppliers

Family Specification - Common to All Four Versions

 

Parameter

Value

Nominal Voltage

300/500 V (U₀/U)

Test Voltage

4000 V

Conductor

Class 6 extra-fine stranded bare copper (VDE 0295 / IEC 60228)

Core Insulation

PVC

Core Lay-up

Cores laid up in layers at a short pitch - very short pitch on the PUR versions

Wrap

Non-woven tape

Inner Sheath

PVC on CY and CP only; the other two run the cores straight under the outer sheath

Screening

Tinned copper braid on CY and CP only

Outer Sheath

PVC grey ≈ RAL 7001 (810, CY) · PUR grey ≈ RAL 7001 (P, CP)

Core Identification

Black cores with white numbers (VDE 0293-1)

Protective Conductor

G = one green-yellow core in the lay-up; X = none

Min. Bending Radius - Moving

7.5 × OD and above

Min. Bending Radius - Fixed

4 × OD

Temperature - Moving

PVC versions 0 °C to +70 °C · PUR versions −5 °C to +70 °C

Temperature - Fixed

−40 °C to +80 °C (all four)

Running Envelope

810: 20 m travel, 20 m/s², 10 m/s, up to 7M cycles · CP: 50 m, 30 m/s², 10 m/s, up to 7M cycles · CY :20 m travel, 20 m/s², 10 m/s, up to 7M cycle · P: 50 m, 30 m/s², 10 m/s, up to 7M cycles

Surface

Low-adhesion, non-stick surface

Flame Retardancy

IEC 60332-1-2

Sheath Standard

VDE 0245 / 0285

ETIM Classification

5.0/6.0 class ID EC000104 - control cable

 

What Changes Between the Four Versions

 

Parameter

FD 810

FD 810 CP

FD 810 CY

FD 810 P

Outer sheath

PVC

PUR

PVC

PUR

Inner sheath

No

PVC

PVC

No

Screening

No

Braid

Braid

No

Moving temp. floor

0 °C

−5 °C

0 °C

−5 °C

OD - 2×0.5

5.3 mm

6.9 mm

6.9 mm

5.3 mm

Cu wt - 2×0.5

10.0 kg/km

33 kg/km (braid adds Cu)

33.0 kg/km

10 kg/km

Cleanroom listed

Yes

No

No

No

 

Note on the AWG Column

 

The catalogue works in mm² only. The AWG column maps each metric size to the nearest conductor area in AWG for buyers whose drawings are dimensioned in AWG — a row-finding aid, not a substitution claim. For drag-chain cable in particular, specify the metric size on the order to ensure the Class 6 conductor construction is what is supplied; an AWG-only specification can result in a Class 5 conductor being quoted instead.

 

Metric (mm²)

AWG

Metric (mm²)

AWG

0.5

20

4

11

0.75

18

6

9

1.0

17

10

7

1.5

15

16

5

2.5

13

—

—

 

OLFLEX CLASSIC FD 810

 

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

0026100

2×0.5

20

5.3

10.0

40

0026104

7G0.5

20

8.0

34.0

88

0026110

50G0.5

20

18.5

240.0

515

0026119

2×0.75

18

5.7

15.0

49

0026123

7G0.75

18

8.9

51.0

117

0026127

25G0.75

18

15.2

181.0

363

0026130

2×1

17

6.1

19.0

58

0026134

7G1

17

9.6

67.0

142

0026144

65G1

17

25.4

624.0

1097

0026149

2×1.5

15

6.8

29.0

74

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

0026153

7G1.5

15

10.9

101.0

189

0026162

50G1.5

15

25.0

720.0

1134

0026170

3G2.5

13

9.0

72.0

145

0026173

7G2.5

13

13.6

168.0

303

0026174

12G2.5

13

16.0

288.0

473

0026180

3G4

11

10.6

120.0

214

0026181

4G4

11

11.7

160.0

266

0026183

4G6

9

13.9

230.4

396

0026185

4G10

7

17.6

384.0

644

0026187

4G16

5

21.0

615.0

922

 

OLFLEX CLASSIC FD 810 CP

 

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

0026400

2×0.5

20

6.9

33

70

0026404

7G0.5

20

9.8

70

138

0026405

12G0.5

20

11.3

100

194

0026419

2×0.75

18

7.3

39

81

0026423

7G0.75

18

10.7

90

171

0026427

25G0.75

18

17.4

271

479

0026430

2×1

17

7.7

46

93

0026434

7G1

17

11.4

110

200

0026439

25G1

17

18.8

365

593

0026449

2×1.5

15

8.4

58

112

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

0026453

7G1.5

15

12.7

145

252

0026457

25G1.5

15

21.2

498

767

0026470

3G2.5

13

10.8

119

199

0026473

7G2.5

13

15.8

262

403

0026475

14G2.5

13

19.8

490

702

0026481

4G4

11

13.7

238

349

0026483

4G6

9

16.1

318

499

0026484

5G6

9

17.7

410

596

0026485

4G10

7

20.2

521

842

0026487

4G16

5

23.6

780

1173

 

Send Inquiry