OLFLEX CLASSIC 115 CY Control Cable

OLFLEX CLASSIC 115 CY Control Cable
Details:
OLFLEX CLASSIC 115 CY thin screened PVC control cable without inner sheath. Maximum transfer impedance 250 Ω/km at 30 MHz, tight 6 × OD bend radius. Request quote.

Standards & Compliance
EN 50525-2-51 | VDE 0293-1 | VDE 0295 / IEC 60228 Class 5 | IEC 60332-1-2 | ISO 4892-2 (115 CY BK)

Quick Specs
300/500 V | 4000 V test | 0.5-2.5 mm², 2-32 cores | 20 × OD flex / 6 × OD fixed | ≤250 Ω/km at 30 MHz
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex classic 115 cy control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

OLFLEX CLASSIC 115 CY is the space-optimised, EMC-screened PVC control cable for modern enclosures and multi-axis machinery where panel volume is tightly constrained. Built without a bulky extruded inner jacket, its tinned-copper braided screen sits directly over the plastic-film-wrapped core lay-up. That architecture reduces overall diameter by 7.3% to 16.7% and trims cable weight by 6.3% to 21.3% against the inner-sheathed screened equivalent, CLASSIC 110 CY. The braid publishes a transfer impedance of no more than 250 Ω/km at 30 MHz, suppressing interference from adjacent variable frequency drives and power switching electronics on instrumentation and PLC loops. Offered in grey PVC (RAL 7001) indoors and UV-stable black PVC (RAL 9005, ISO 4892-2) outdoors, it ships as bulk reels, cut lengths or pre-wired harnesses.

 

Select Your Variant

 

Installation & Environmental Requirement

Recommended Model

Engineering Justification

Indoor machinery cabinets, high-density wire ducts, PLC racks

OLFLEX CLASSIC 115 CY (Grey)

Standard industrial grey PVC jacket (RAL 7001). Maximum routing flexibility in dry/damp indoor environments.

Outdoor cable bridges, solar-adjacent machinery, external conduits

OLFLEX CLASSIC 115 CY BK (Black)

Special black PVC outer jacket certified to ISO 4892-2 UV/weather resistance. Prevents photo-degradation and micro-cracking.

Severe mechanical impact or heavy direct burial

Consider Double-Sheathed CLASSIC 110 CY

When mechanical crushing or sharp conduit bends present a hazard of braid puncture, an extruded inner sheath provides an extra mechanical cushion.

Continuous flexing or high-speed drag chain motion

Specify OLFLEX CLASSIC FD 810 CY

115 CY is engineered for fixed routing (occasional flex only). Drag-chain duty calls for a finer-stranded conductor construction than the Class 5 stranding used here.

 

Typical Applications

 

01high-density-industrial-control-cabinet-plc-i-o-rack-relays-and-terminal-blocks-wired-with-ferruled-cores-inside-a-densely-packed-panel

High-Density Industrial Control Cabinets
Interconnecting multi-channel PLC I/O racks, signal conditioning modules, and relay blocks in space-restricted automated panels.

02precision-machine-tools-and-packaging-machinery-junction-box-with-a-numbered-terminal-strip-and-blue-white-control-cores-on-a-machine-frame

Precision Machine Tools & Packaging Machinery
Supplying control commands across fixed machinery frames and junction boxes subjected to moderate industrial vibration.

03cable-carrier-on-a-moving-machine-axis-energy-chain-guiding-control-cores-along-the-linear-travel-inside-a-machine-frame

HVAC & Building Management Systems
Wiring central chiller monitoring sensors, damper actuators, and air-handling unit instrumentation exposed to nearby pump electrical noise.

04open-energy-chain-with-red-cores-running-through-the-links-shown-as-a-product-view-on-a-white-background

Wind Turbine Generator (WTG) Nacelle Loops
Accommodating torsional twisting stress in flexible vertical cable loops hanging between the nacelle and the stationary tower platform.

 

Why Choose OLFLEX CLASSIC 115 CY Series

 

Advantage

What It Means On Site

Verified Transfer Impedance Suppresses Inverter Noise

Instead of ambiguous optical coverage percentages, 115 CY is benchmarked by a rigorous transfer impedance limit of ≤ 250 Ω/km at 30 MHz. This guarantees robust attenuation against high-frequency pulse-width-modulated (PWM) switching spikes generated by adjacent AC servo drives and frequency converters, eliminating spurious trigger signals on 24V DC logic lines.

Space Optimization Accelerates Panel Building

Removing the inner jacket yields a 7.3% to 16.7% diameter reduction across the catalogue sizes. In a crowded wire duct carrying 20 to 30 control lines, this translates into a 14% to 31% reduction in cross-sectional area. Smaller outer diameters also allow panel fitters to specify smaller, lower-cost cable entry glands and tighter punch-out patterns on cabinet entry plates.

Single-Jacket Stripping Cuts Termination Hours

On multi-conductor cables with an inner sheath, terminating each connection requires two separate stripping cuts (outer sheath then inner sheath) plus careful braid combing. With 115 CY, installers make a single clean ring-cut through the outer PVC, peel back the copper braid for 360° EMC grounding, and immediately access the wrapped cores, cutting termination time on site.

Tight 6 × OD Bending Geometry for Restricted Enclosures

Conventionally shielded control cables require 10 × to 15 × OD bending clearances to prevent braid deformation. The precision-braided 115 CY achieves a certified 6 × OD static bend radius. This tight profile enables neat, sharp right-angle routing inside shallow operator consoles, compact sensor junction boxes, and slim machine tool raceways.

 

Cabinet Packing Density: Space & Weight Savings vs CLASSIC 110 CY

 

In automated machinery and compact motor control centers (MCC), traditional screened cables equipped with extruded inner PVC sheaths consume disproportionate wire-duct cross-section. By eliminating the inner layer while preserving electromagnetic shielding effectiveness, OLFLEX CLASSIC 115 CY frees up critical pathway volume and simplifies cable gland entry:

 

Conductor Size (Cores × mm²)

CLASSIC 110 CY (Inner Sheath)

CLASSIC 115 CY (No Inner Sheath)

Outer Diameter Reduction

Weight Savings (kg/km)

4 G 0.75 mm²

OD: 8.4 mm | Wt: 115 kg/km

OD: 7.0 mm | Wt: 95 kg/km

−1.4 mm (−16.7%)

20 kg/km less (−17.4%)

4 G 1.5 mm²

OD: 9.6 mm | Wt: 163 kg/km

OD: 8.2 mm | Wt: 135 kg/km

−1.4 mm (−14.6%)

28 kg/km less (−17.2%)

5 G 1.5 mm²

OD: 10.3 mm | Wt: 188 kg/km

OD: 8.9 mm | Wt: 148 kg/km

−1.4 mm (−13.6%)

40 kg/km less (−21.3%)

7 G 1.5 mm²

OD: 11.3 mm | Wt: 237 kg/km

OD: 9.9 mm | Wt: 192 kg/km

−1.4 mm (−12.4%)

45 kg/km less (−19.0%)

4 G 2.5 mm²

OD: 11.3 mm | Wt: 233 kg/km

OD: 9.9 mm | Wt: 188 kg/km

−1.4 mm (−12.4%)

45 kg/km less (−19.3%)

4 G 10 mm²

OD: 19.0 mm | Wt: 735 kg/km

OD: 17.2 mm | Wt: 680 kg/km

−1.8 mm (−9.5%)

55 kg/km less (−7.5%)

4 G 35 mm²

OD: 30.2 mm | Wt: 2210 kg/km

OD: 28.0 mm | Wt: 2070 kg/km

−2.2 mm (−7.3%)

140 kg/km less (−6.3%)

 

Frequently Asked Questions

 

Q: How does 115 CY maintain high EMC protection without an inner jacket?

A: An inner sheath in conventional cables primarily provides mechanical separation and roundness, contributing zero electrical screening value. OLFLEX CLASSIC 115 CY replaces the bulky inner PVC jacket with a thin, low-friction synthetic film wrap that secures the concentric core geometry. The dense tinned copper wire braid is then applied directly over this core wrap with an optical coverage of approx. 85%, ensuring continuous surface conductivity and maintaining a transfer impedance of ≤ 250 Ω/km at 30 MHz.

Q: When should an engineer choose 115 CY over the traditional CLASSIC 110 CY?

A: Specify 115 CY whenever installation space, cable bundle weight, or termination speed are critical design factors - particularly inside crowded machinery enclosures, compact multi-axis junction boxes, or dense vertical riser ducts where 115 CY provides a 7.3% to 16.7% diameter reduction and trims weight by 6.3% to 21.3%. However, if the cable route involves sharp sheet-metal edges, high risk of external mechanical crushing, or direct burial in harsh industrial trenches, CLASSIC 110 CY with its extruded inner jacket offers enhanced mechanical puncture protection.

Q: Can OLFLEX CLASSIC 115 CY be installed in continuous cable drag chains?

A: No. 115 CY is specifically engineered for fixed wiring and occasional non-continuous motion. It features VDE Class 5 stranded conductors and an occasional flex rating of 20 × OD. In continuous high-speed drag chain operation (millions of cycles), the mechanical shear stress between the un-cushioned braid and conductors would eventually cause metal fatigue and internal core wear. For continuous drag-chain service, specify OLFLEX CLASSIC FD 810 CY or OLFLEX CHAIN 809 CY.

Q: What is the proper procedure for terminating the 360° EMC braid at the cabinet entry?

A: To achieve maximum noise attenuation at radio frequencies, the braided shield should be grounded using a shielded EMC cable gland or a dedicated 360° earthing clamp connected directly to the enclosure equipotential chassis plate. Avoid twisting the braid into a thin 'pigtail' wire lead, as pigtails introduce parasitic inductive reactance that severely degrades high-frequency EMI dissipation above 1 MHz.

Q: What is the exact difference between the grey and black sheath versions?

A: Both versions share identical Class 5 conductors, LAPP P8/1 PVC insulation, high-coverage tinned copper braiding, and overall dimensions. The standard grey version (RAL 7001) is engineered for indoor automated equipment and dry/damp machinery spaces. The black version (CLASSIC 115 CY BK, RAL 9005) features a specialized UV-stabilized and weather-resistant PVC outer jacket certified to ISO 4892-2, preventing sheath embrittlement and cracking when routed outdoors or exposed to direct sunlight.

Q: Does KABASI provide custom wire harness assemblies using OLFLEX CLASSIC 115 CY?

A: Yes. As a certified wire harness manufacturer and cable sourcing specialist, KABASI supplies bulk spools, exact cut lengths, and turnkey pre-assembled control harnesses. We process 115 CY with circular industrial connectors (M12, M23, MIL-spec), heavy-duty rectangular connectors (EPIC / Harting types), or pre-crimped terminal ferrules with 360° shield ground lugs according to your schematic drawings.

 

 

Hot Tags: olflex classic 115 cy control cable, China olflex classic 115 cy control cable suppliers

Electrical & Mechanical Performance Data

 

Electrical & Mechanical Property

Engineering Specification Value

Nominal Operating Voltage (U₀/U)

300/500 V (AC RMS)

Factory Dielectric Proof Test

Core / Core: 4000 V AC | Core / Screen: 2000 V AC

Conductor Construction

Bare copper strands, Class 5 fine-wire flexible stranding according to VDE 0295 / IEC 60228

Core Dielectric Insulation

Specially formulated lead-free PVC insulation compound (LAPP P8/1)

Core Numbering & Color Coding

Black core insulation with continuous white Arabic numbering to VDE 0293-1; with (G) or without (X) green-yellow earth

Conductor Lay-up & Interlayer Wrap

Cores twisted in concentric layers with optimized pitch; bound with transparent plastic film wrapping

Electromagnetic Shielding Layer

Tinned copper wire braided screen; optical coverage approx. 85%; surface transfer impedance ≤ 250 Ω/km at 30 MHz

Outer Protective Sheath

Flame-retardant PVC compound; Grey (approx. RAL 7001) or Black (approx. RAL 9005, UV stabilized)

Fixed Installation Bending Radius

6 × outer cable diameter (exceptionally tight for screened multi-core cables)

Occasional Motion Bending Radius

20 × outer cable diameter (free non-continuous movement without mechanical tensile stress)

Temperature Range (Static)

−40 °C to +80 °C (permanent fixed installation)

Temperature Range (Dynamic)

−5 °C to +70 °C (occasional flexing service)

Wind Turbine Nacelle Torsion Rating

TW-0 (+5 °C to +70 °C, ±150°/m, 5,000 cycles) and TW-1 (−20 °C to +70 °C, ±150°/m, 2,000 cycles)

Flame Spread Retardancy

Self-extinguishing and flame-retardant in accordance with IEC 60332-1-2

Chemical Resistance

High chemical stability against mineral oils, dilute acids, and aqueous washdown solutions (refer to Catalog Annex T1)

 

Sizing Reference & Cross-Section Lookup

 

All conductor cross-sections are manufactured to metric standards (VDE 0295 / IEC 60228 Class 5). The integrated AWG reference in the ordering tables indicates the closest equivalent conductor cross-section for North American project cross-referencing and terminal lug sizing.

 

OLFLEX CLASSIC 115 CY (Grey Outer Sheath) — Popular Selection

 

Part No.

Cores × Conductor (mm²)

Approx. AWG

Outer Diam. (mm)

Copper Index (kg/km)

Cable Weight (kg/km)

1136752

2 × 0.5

20

5.8

36.0

54

1136003

3 G 0.5

20

6.1

43.0

63

1136004

4 G 0.5

20

6.5

49.0

71

1136005

5 G 0.5

20

7.0

57.0

86

1136007

7 G 0.5

20

7.5

69.0

105

1136762

12 × 0.5

20

9.9

104.0

200

1136775

25 × 0.5

20

13.4

211.0

350

1136802

2 × 0.75

18

6.2

43.0

56

1136103

3 G 0.75

18

6.5

52.0

70

1136104

4 G 0.75

18

7.0

61.0

95

1136804

4 × 0.75

18

7.0

61.0

95

1136121

21 G 0.75

18

14.0

258.0

393

1136132

32 G 0.75

18

16.3

388.0

551

Part No.

Cores × Conductor (mm²)

Approx. AWG

Outer Diam. (mm)

Copper Index (kg/km)

Cable Weight (kg/km)

1136852

2 × 1.0

17

6.5

51.0

71

1136203

3 G 1.0

17

6.8

62.0

66

1136204

4 G 1.0

17

7.3

74.0

98

1136205

5 G 1.0

17

8.1

88.0

121

1136303

3 G 1.5

15

7.5

82.0

112

1136304

4 G 1.5

15

8.2

100.0

135

1136325

25 G 1.5

15

17.9

530.0

734

1136404

4 G 2.5

13

9.9

147.0

188

1136403

3 G 2.5

13

8.9

118.0

151

1136604

4 G 6.0

9

14.2

343.0

440

1136607

7 G 6.0

9

17.0

505.0

672

1136504

4 G 4.0

11

11.6

248.0

305

           

 

OLFLEX CLASSIC 115 CY BK (Black UV-Resistant Sheath) — Popular Selection

 

Part No.

Cores × Conductor (mm²)

Approx. AWG

Outer Diam. (mm)

Copper Index (kg/km)

Cable Weight (kg/km)

1136510

2 × 0.5

20

5.8

36.0

54

1136511

3 G 0.5

20

6.1

43.0

63

1136110

3 G 0.75

18

6.5

52.0

76

1136115

12 G 0.75

18

10.9

138.0

232

1136536

3 G 1.0

17

6.8

62.0

86

1136544

12 G 1.0

17

11.5

185.0

249

1136548

3 G 1.5

15

7.5

82.0

112

1136554

7 G 1.5

15

9.9

154.0

192

1136556

12 G 1.5

15

13.0

268.0

332

1136560

3 G 2.5

13

8.9

118.0

151

1136566

4 G 4.0

11

11.6

248.0

287

1136568

4 G 10.0

7

17.2

495.0

637

1136573

4 G 35.0

2

28.0

1576.0

2070

 

Send Inquiry