Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex robust 200 connecting cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Lead Paragraph
OLFLEX ROBUST 200 is the heavy-duty, all-weather flexible power and connecting cable for equipment exposed to chemical washdowns, biological oils and extreme environments. It carries a full 450/750 V rating in conductor sizes up to 4G50 mm², where most chemical-resistant lines are thin 300/500 V signal cables. A modified TPE outer jacket over low-capacitance polypropylene insulation resists animal fats, vegetable emulsions, liquid manure and food-industry cleaning agents, and stays flexible to −50 °C fixed and −40 °C during handling. EN 50565-2 certifies permanent freshwater submersion to 10 m, so the same cable serves processing floors, car washes and wastewater plants.
Select Your Variant
Core Identification: Color-Coded Power vs. Numbered Multi-Core
|
Conductor Count |
Identification Scheme |
Standard Conductor Layout |
Intended Circuit Function |
|
2 to 5 Cores (Primary Power) |
Color-coded per VDE 0293-308 |
2-core: blue, brown | 3-core: green-yellow, blue, brown | 4-core: green-yellow, brown, black, grey | 5-core: green-yellow, blue, brown, black, grey |
Standard three-phase AC motor feeds, neutral-return power hookups, and commercial portable machinery where color-coded phasing prevents reverse motor rotation. |
|
7 Cores (Power + Interlock) |
Black cores with continuous white Arabic numbering + green-yellow earth |
Core numbers 1 through 6 printed clearly on black insulation + 1 green-yellow center/outer core |
Combined machine power feeds with integrated thermal overload switches, safety brake controls, or interlock monitoring lines. |
ROBUST Family Comparison: Connecting vs. Control Cables
|
Cable Model |
Primary Engineering Function |
Voltage Rating |
Conductor Size Range |
Core Identification System |
|
OLFLEX ROBUST 200 |
Heavy power and main equipment connecting cable |
450/750 V (Heavy Duty) |
1.0 mm² up to 4G50.0 mm² |
Color-coded to VDE 0293-308 (2–5 cores); numbered for 7-core |
|
OLFLEX ROBUST 210 |
Multi-conductor machine control and sensing line |
300/500 V (Control Level) |
0.5 mm² up to 35 mm² (up to 50 cores) |
Black numbered cores across all sizes per VDE 0293-1 |
|
OLFLEX ROBUST 215 C |
Screened control cable with copper braided shield |
300/500 V (Control Level) |
0.5 mm² up to 35 mm² (screened) |
Black numbered cores under tinned copper braid for EMC-sensitive sensor loops |
Typical Applications




Why Choose OLFLEX ROBUST 200 Series
|
Advantage |
What it means on site |
|
True 450/750 V Power Rating Across Full Range Up to 50 mm² |
Most chemical-resistant cables are thin 300/500 V signal lines. ROBUST 200 delivers full 450/750 V dielectric rating with heavy copper cross-sections up to 50 mm², enabling direct connection of high-power motors, heaters, and agitators without intermediate junction boxes. |
|
Sub-Zero Flexibility Down to −50 °C Without Shattering |
Where conventional cables crack and lose insulation integrity in refrigerated cold storage or winter outdoor installations, the modified TPE jacket retains elastomeric flexibility down to −50 °C fixed and −40 °C flexing. |
|
Dual Immunity: Chemical Cleaning Plus 10 m Water Submersion |
Combines certified resistance to food-industry cleaning agents against caustic foam with EN 50565-2 freshwater submersible capability, allowing one cable inventory to serve both processing room floors and outdoor wet retention pits. |
|
Color-Coded Cores Prevent Phasing Errors on Heavy Motors |
Conductors up to 5 cores utilize standard European color codes per VDE 0293-308, eliminating phase identification mistakes during field motor commissioning and preventing reverse impeller rotation. |
Submersible & Sub-Zero Cold-Installation Guidelines (EN 50565-2)
Operating a flexible cable underwater or in sub-zero freezer warehouses imposes physical constraints that standard electrical tables omit. Review these engineering rules before specifying OLFLEX ROBUST 200:
|
Application Condition |
Certified Engineering Boundary |
Field Installation Precaution |
|
Continuous Submerged Service (EN 50565-2) |
Maximum freshwater depth: 10 meters; Maximum water temperature: +40 °C |
Cable glands entering submerged pump motor casings must be IP68 rated with TPE elastomeric compression inserts. Avoid salt water or marine bio-fouling zones. |
|
Deep Freeze Arctic Mobility |
Supple dynamic flexing down to −40 °C; Static routing down to −50 °C |
Unlike PVC which turns brittle and shatters under impact at −5 °C, ROBUST 200 retains shock elasticity. Do not flex cable beyond 10 × OD when temperature drops below −30 °C. |
|
Steam Jet & CIP Clean-in-Place |
Withstands direct washdown nozzles with hot water and saturated steam up to +80 °C |
Maintain a minimum spray distance of 150 mm when using rotating zero-degree steam jet nozzles to prevent localized sheath surface erosion. |
Frequently Asked Questions
Q: What is the fundamental difference between ROBUST 200 and ROBUST 210?
A: ROBUST 200 is engineered as a heavy-duty power and connecting cable: it operates at 450/750 V, spans conductor sizes up to 4G50 mm², and features color-coded cores (VDE 0293-308) up to 5 cores for direct three-phase motor wiring. In contrast, ROBUST 210 is a 300/500 V multi-core control cable with fine conductors (0.5 to 35 mm²), up to 50 cores, and consecutive number-printed black cores for sensor and relay cabling.
Q: Can OLFLEX ROBUST 200 be permanently submerged underwater?
A: Yes. ROBUST 200 is officially tested and certified under EN 50565-2 for continuous freshwater immersion down to a depth of 10 meters at water temperatures up to +40 °C. It is ideally suited for submersible aerators, wastewater clarifiers, and decorative fountains.
Q: Why is modified polypropylene (PP) used for insulation instead of standard PVC?
A: Modified PP offers substantially higher dielectric breakdown strength and lower mutual capacitance than PVC, making the cable lighter and more compact. Chemically, PP is completely immune to water absorption and will not leach plasticizers when exposed to biological oils and hot caustic washdowns.
Q: How does ROBUST 200 perform in outdoor and cold climate environments?
A: The black TPE outer sheath is compounded with UV stabilizers and antioxidants compliant with EN 50396 and HD 605 S2. It resists solar degradation, ozone cracking, and remains flexible down to −40 °C flexing and −50 °C fixed, eliminating winter weather embrittlement.
Q: Can KABASI supply ROBUST 200 pre-terminated with heavy waterproof connectors?
A: Yes. KABASI specializes in industrial wire harness processing. We provide cut-to-length ROBUST 200 leads pre-fitted with IP68/IP69K stainless steel or nickel-plated brass cable glands, heavy-duty industrial plugs, and custom pinouts verified under automated testing.
Hot Tags: olflex robust 200 connecting cable, China olflex robust 200 connecting cable suppliers
Electrical, Thermal & Mechanical Ratings
|
Technical Parameter |
Standard Reference & Certified Value |
|
Conductor Construction |
Fine-wire bare copper conductor strands according to VDE 0295 Class 5 / IEC 60228 Class 5 |
|
Core Insulation |
Modified polypropylene (PP) compound; low dielectric loss and high insulation resistance |
|
Core Identification |
2 to 5 cores: color-coded per VDE 0293-308 (Appendix T9) | 7 cores: black with white numbers (VDE 0293-1) |
|
Outer Sheath Material |
Special modified thermoplastic elastomer (TPE), jet-black (weather, ozone, and UV resistant) |
|
Rated Operating Voltage (U₀/U) |
450/750 V AC (heavy industrial power rating) |
|
Dielectric Test Voltage |
4000 V AC |
|
Minimum Bending Radius |
Occasional flexing: 10 × cable outer diameter | Fixed installation: 4 × cable outer diameter |
|
Operational Temperature Range |
Occasional flexing: −40 °C to +80 °C | Fixed installation: −50 °C to +80 °C |
|
Submersion Rating |
Certified for freshwater submersion up to 10 m depth at max. +40 °C water temperature per EN 50565-2 |
|
Oil & Chemical Resistance |
EN 50363-4-1 (TM5); resistant to bio-oils, plant fats, greases, waxes, and synthetic emulsions |
|
Weathering & Ozone Resistance |
Certified resistant to ozone, UV radiation, and atmospheric weathering according to EN 50396 and HD 605 S2 |
|
Halogen-Free Attribute |
Halogen-free compound formulation ensures zero corrosive acid gas generation under fire |
|
Standard Packaging |
Coil up to 30 kg / 250 m; wooden drum above that weight threshold |
Chemical Resistance Matrix
Chemical resistance on this cable is a list, not a blanket claim: the sheath is rated for the five media groups below, and anything outside them has not been assessed. Send the medium and its concentration and we will put it to the factory before the order.:
| Industrial medium |
OLFLEX ROBUST 200 |
| Animal and vegetable oils, bio-oils, emulsions, waxes and greases | Good resistance |
| Ammonia compounds and biogas | Good resistance |
| Hot and cold water, water-soluble detergents and coolants | Good resistance |
| Disinfectants and cleaning agents used in food and beverage processing | Certified resistance |
| Ester-based hydraulic oils | Good chemical resistance |
Metric to AWG Reference Notice
All conductor sizes are produced strictly to IEC 60228 metric standards. The cross-reference table below provides approximate AWG / kcmil equivalents for North American specifications. State the metric Lapp part number when placing orders.
|
Metric Section (mm²) |
Approximate AWG Equivalent |
|
1.0 |
17 |
|
1.5 |
15 |
|
2.5 |
13 |
|
4.0 |
11 |
|
6.0 |
9 |
|
10.0 |
7 |
|
16.0 |
5 |
|
25.0 |
3 |
|
35.0 |
2 |
|
50.0 |
1/0 |
OLFLEX ROBUST 200
Certified all-weather chemical-resistant flexible power and connecting cable (450/750 V). G = includes green-yellow protective earth core; X = without green-yellow core. Selected listing from 0021800 to 0021836.
|
Part No. |
Cores × mm² |
AWG |
Outer Diameter (mm) |
Copper Index (kg/km) |
Total Weight (kg/km) |
|
0021800 |
2 X 1.0 |
17 |
8.0 |
19.2 |
65 |
|
0021801 |
3 G 1.0 |
17 |
8.4 |
29.0 |
79 |
|
0021803 |
5 G 1.0 |
17 |
10.0 |
48.0 |
113 |
|
0021805 |
2 X 1.5 |
15 |
8.6 |
29.0 |
78 |
|
0021806 |
3 G 1.5 |
15 |
9.1 |
43.0 |
97 |
|
0021808 |
5 G 1.5 |
15 |
10.8 |
72.0 |
146 |
|
0021809 |
7 G 1.5 |
15 |
13.5 |
101.0 |
208 |
|
0021810 |
2 X 2.5 |
13 |
9.8 |
48.0 |
114 |
|
0021811 |
3 G 2.5 |
13 |
10.4 |
72.0 |
144 |
|
0021813 |
5 G 2.5 |
13 |
13.1 |
120.0 |
222 |
|
Part No. |
Cores × mm² |
AWG |
Outer Diameter (mm) |
Copper Index (kg/km) |
Total Weight (kg/km) |
|
0021814 |
7 G 2.5 |
13 |
15.9 |
168.0 |
312 |
|
0021816 |
3 G 4.0 |
11 |
12.4 |
115.2 |
215 |
|
0021817 |
4 G 4.0 |
11 |
14.0 |
154.0 |
273 |
|
0021818 |
5 G 4.0 |
11 |
15.8 |
192.0 |
333 |
|
0021822 |
4 G 6.0 |
9 |
15.7 |
230.0 |
378 |
|
0021825 |
4 G 10.0 |
7 |
19.4 |
384.0 |
570 |
|
0021828 |
4 G 16.0 |
5 |
22.4 |
614.0 |
885 |
|
0021831 |
4 G 25.0 |
3 |
27.0 |
960.0 |
1365 |
|
0021833 |
4 G 35.0 |
2 |
29.7 |
1344.0 |
1773 |
|
0021836 |
4 G 50.0 |
1/0 |
36.2 |
1920.0 |
3454 |