OLFLEX CLASSIC 110 CY Control Cable

OLFLEX CLASSIC 110 CY Control Cable
Details:
OLFLEX CLASSIC 110 CY screened PVC control cable: tinned copper braid with ≤250 Ω/km transfer impedance at 30 MHz, grey inner sheath, transparent outer sheath, VDE Reg. No. 7030 (cable series), 4 kV test voltage.

Standards & Compliance
VDE Reg. No. 7030 (series) | VDE 0295 / IEC 60228 Class 5 | VDE 0293-1 | IEC 60332-1-2 | EMC Compliance (≤ 250 Ω/km @ 30 MHz)

Quick Specs
300/500 V | 4000 V AC | 0.5 – 35 mm² (Screened) | −40 °C to +80 °C fixed | Transparent outer sheath over tinned copper braid
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex classic 110 cy control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

OLFLEX CLASSIC 110 CY is the double-sheathed, screened PVC control cable for electrically noisy industrial environments where signal integrity and interference immunity are critical. A high-density tinned copper braid over a robust grey PVC inner sheath, beneath a transparent outer jacket, delivers certified EMC performance with transfer impedance below 250 Ω/km at 30 MHz. Unlike unshielded control lines that pick up switching spikes, or light-screened types lacking inner bedding, it isolates sensitive 300/500 V control, measurement and sensor loops running parallel to variable frequency drives and heavy switchgear. The cable series carries VDE registration no. 7030, and every length is spark-tested at 4000 V. KABASI supplies cut-to-length bulk cable or completed harnesses fitted with 360° EMC glands and multi-pole connectors.

 

Select Your Variant

 

Protective Earth vs. Clean Measurement Ground (G vs. X)

Configuration

Designation Format

Internal Identification

Best Practice Application

G (With Protective Conductor)

e.g. 4 G 1.5, 7 G 0.75, 12 G 1

Includes 1 green-yellow core + consecutively numbered black cores

Standard choice for machinery control, motor auxiliary circuits, interlocks, and push-button stations requiring equipment chassis PE bond.

X (Without Protective Conductor)

e.g. 2 X 0.75, 4 X 1, 12 X 0.5

Only black cores with white consecutive numbers; zero green-yellow

Preferred for clean DC control circuits, isolated measurement bridges, two-wire 4–20 mA instrumentation, or where PE must not enter the signal bundle.

 

Structural Comparison: CLASSIC 110 CY vs. Sibling Control Cables

Cable Model

Shielding Architecture

Inner Sheath

Outer Sheath Style

Primary Engineering Intent

OLFLEX CLASSIC 110 CY

Tinned copper braid (Z_T ≤ 250 Ω/km)

Grey PVC bedding layer

Transparent clear PVC

EMC interference immunity with visual braid inspection for control/drive environments.

OLFLEX CLASSIC 110 (Unshielded)

None

None

Silver-grey or black PVC

Cost-effective, highly flexible control cabling where EMC cross-talk is absent.

OLFLEX CLASSIC 115 CY

Tinned copper braid

None (wrap over cores)

Silver-grey PVC

Ultra-compact outer diameter where tight installation space outweighs mechanical crush protection.

OLFLEX CLASSIC 110 SY

Galvanized steel wire braid (SY)

Grey PVC bedding layer

Transparent clear PVC

Severe mechanical crush, gouge, and rodent protection on factory floor pathways.

 

Typical Applications

 

01plant-engineering-and-industrial-machinery-control-panel-harness-with-a-monitoring-screen-terminal-strips-and-cable-bundles-on-a-test-bench

Plant Engineering and Industrial Machinery
Wiring that has to fit a space already fixed - class 5 fine-wire copper, 6 × OD fixed and 20 × OD occasional flexing.

02heating-and-air-conditioning-installation-terminal-rail-carrying-green-yellow-blue-red-and-orange-core-bundles-into-labelled-terminal-blocks

Heating and Air-Conditioning Installation
A dozen signals on one terminal rail - black cores with white numerals to VDE 0293-1, so each circuit is read by number.

03conveyor-and-transport-systems-powered-roller-conveyor-line-running-through-a-plant-hall-with-cables-following-the-frame

Conveyor and  Transport Systems
A cable that follows the line rather than staying fixed - 20 × OD occasional flexing through −5 to +70 °C.

04emc-sensitive-environment-braided-shielded-cables-with-a-transparent-outer-sheath-landing-on-numbered-terminals-inside-a-control-cabinet

EMC-Sensitive Environments
Tinned copper braid over a grey inner sheath, under a transparent outer sheath that keeps the braid visible along the run.

 

Why Choose OLFLEX CLASSIC 110 CY Series

 

Advantage

What it means on site

True Double-Sheath Construction Protects Core Insulation

Unlike single-sheathed screened cables where the metallic braid sits directly against insulated cores, CLASSIC 110 CY incorporates a robust grey PVC inner jacket. This provides mechanical cushioning under gland compression and ensures the tinned copper braid never abrades or punctures core insulation during flexing.

Verified Transfer Impedance (≤ 250 Ω/km at 30 MHz)

High-speed PWM drives and servo choppers radiate intense interference between 1 MHz and 30 MHz. By guaranteeing transfer impedance below 250 Ω/km, CLASSIC 110 CY prevents control channel corruption, eliminating the phantom fault trips common with unverified generic cables.

Transparent Jacket for Zero-Downtime Inspection

The clear PVC formulation allows maintenance personnel to inspect shield continuity, braid density, and spot mechanical pinching or internal water ingress instantly without slitting or removing outer insulation.

4000 V Proof Test & Full VDE Quality Auditing

Tested at four times the rated operational voltage (4 kV AC) and covered by the cable series' VDE registration no. 7030, this series delivers zero dielectric defect leakage for continuous operation in automated production environments.

 

Frequently Asked Questions

 

Q: Why choose CLASSIC 110 CY instead of the thinner CLASSIC 115 CY?

A: CLASSIC 110 CY features an extruded grey PVC inner sheath beneath the copper braid, whereas 115 CY omits the inner sheath to achieve minimum outer diameter. Choose 110 CY when cables undergo frequent mechanical clamping, gland compression, or vibration, because the inner jacket prevents braid strands from penetrating core insulation. Choose 115 CY only when cabinet volume is severely restricted.

Q: What is the advantage of a transparent outer sheath on a screened cable?

A: Transparency enables instant visual verification of shield integrity without stripping or damaging the cable. Field engineers can quickly detect braid unraveling, chemical oxidation, severe bend kinks, or moisture penetration during routine visual audits, avoiding unexpected production outages.

Q: Should the braid be landed with a 360° clamp or a twisted pigtail?

A: A 360° clamp is the better landing for screened cable: the braid is bonded around its full circumference, so the screen stays a low-impedance path at high frequency. A twisted pigtail leaves most of the braid unconnected and puts inductance exactly where the screen meets earth. Neither method is part of the cable; it is how the screen is landed at the gland or the clamp.

Q: What is the operational difference between G and X part numbers?

A: Rows designated with G include a green-yellow protective earth (PE) grounding conductor. Rows designated with X have solely black numbered cores without green-yellow. In screened cables, G is standard for machinery and interlocks, while X is favored for clean isolated instrumentation loops where PE loop loops must be avoided.

Q: Can KABASI supply pre-terminated CLASSIC 110 CY assemblies with EMC glands?

A: Yes. KABASI operates precision stripping, braided screen combing, and automated terminal crimping production lines. We deliver complete custom harnesses pre-fitted with IP68 EMC brass glands, heavy-duty connectors, and custom wire pinouts ready for direct machine drop-in.

 

 

Hot Tags: olflex classic 110 cy control cable, China olflex classic 110 cy control cable suppliers

Electrical & Mechanical Performance Data

 

Parameter

Specification Standard / Technical Value

Conductor Construction

Fine-wire bare copper conductor strands according to VDE 0295 Class 5 / IEC 60228 Class 5

Core Insulation

Special PVC compound LAPP P8/1; optimal dielectric breakdown strength

Core Identification

Black cores with white consecutive Arabic numerals per VDE 0293-1; optional green-yellow earth (G)

Inner Sheath (Bedding)

Lead-free PVC compound, grey; cushions core bundle and provides uniform cylindrical braid seat

Screening / Braid

Tinned copper wire braided shield; high optical coverage and low transfer impedance

Outer Sheath

Special transparent PVC compound; flame retardant to IEC 60332-1-2

Rated Voltage (U₀/U)

300/500 V

Dielectric Test Voltage

4000 V AC (spark tested for high insulation reliability)

Transfer Impedance

Maximum 250 Ω/km at 30 MHz per transfer measurement method

Minimum Bending Radius

Occasional flexing: 20 × cable outer diameter | Fixed installation: 6 × cable outer diameter

Temperature Range

Occasional flexing: −5 °C to +70 °C | Fixed installation: −40 °C to +80 °C

Flame Retardancy

Flame-retardant according to IEC 60332-1-2 (vertical single-wire flame test)

Chemical Resistance

Good resistance against light industrial oils, dilute acids, and alkaline solutions

Standard Packaging

Coils up to 30 kg / 250 m; wooden or steel drums above that threshold

 

EMC Transfer Impedance & Screening Efficiency

 

Electromagnetic shielding in an industrial control cabinet cannot be assessed by visual braid coverage alone; high-frequency interference immunity is governed by transfer impedance (Z_T). OLFLEX CLASSIC 110 CY is manufactured to an engineered transfer impedance ceiling of ≤ 250 Ω/km at 30 MHz to guarantee active noise suppression across switching harmonics.

 

Noise Frequency Band

Primary Industrial Source

CLASSIC 110 CY Protection Mechanism

Practical Field Outcome

10 kHz – 150 kHz (Conducted Low-Freq)

SCR heating controllers, line power harmonics, heavy motor starters

Closed copper mass density minimizes low-frequency inductive cross-coupling

Eliminates 50/60 Hz hum and slow sensor zero-drift in analog process channels

150 kHz – 30 MHz (HF Commutation)

VFD pulse-width modulation (PWM) carrier frequencies, servo inverter spikes

Optimized braid weave angle achieves transfer impedance ≤ 250 Ω/km at 30 MHz benchmark

Prevents digital I/O false triggers and relay chatter in runs parallel to drive cables

30 MHz – 100 MHz (VHF Radiated)

Relay coil arc discharge, contactor bounce, unsuppressed solenoid kicks

Tinned copper braid coverage blocks radiated RF intrusion through cabinet entryways

Guarantees encoder count accuracy and PLC communication bus integrity without packet drops

 

The transparent PVC outer jacket provides continuous visual verification of the braid condition: any installation pinch, mechanical crushing, chemical corrosion, or braid unraveling can be identified during routine maintenance without cutting the cable jacket open.

 

Termination & 360° Shield-Bonding Practice

 

An EMC-screened cable is only as effective as its ground termination. Pigtailing the braided screen into a thin wire terminal compromises high-frequency shielding due to localized inductance. Follow these industrial termination rules for OLFLEX CLASSIC 110 CY:

 

Termination Technique

EMC Performance at >10 MHz

Recommended Hardware

Critical Installation Step

360° Circumferential EMC Cable Gland

Optimal (95–99% effectiveness)

Brass EMC gland with contact springs

Strip transparent outer sheath by 15–20 mm; seat internal grounding springs directly onto the exposed tinned copper braid.

EMC Saddle Clamp on Ground Busbar

High (80–90% effectiveness)

C-rail copper spring saddle or earthing clip

Strip only the transparent outer jacket over the clamp zone; torque saddle directly over the braid to a copper earth rail.

Twisted Pigtail Ground (Not Recommended)

Severe degradation (<30% effectiveness)

Ground lug crimped on twisted braid tail

Never use pigtails on VFD motor or encoder lines; inductive choke creates high-frequency ground bounce inside the cabinet.

 

The grey PVC inner sheath prevents the braid from biting into individual core insulation during tight cable gland tightening, safeguarding against core-to-shield short circuits under mechanical vibration.

 

Metric to AWG Reference Notice

 

All cable dimensions and core structures on this page are manufactured strictly to IEC 60228 metric units. The table below provides nominal area equivalence for North American electrical drawings. Specify the metric part number on formal purchase orders to prevent dimensional mismatch.

 

Metric Section (mm²)

Approximate AWG Equivalent

0.5

20

0.75

18

1.0

17

1.5

15

2.5

13

4.0

11

6.0

9

10.0

7

16.0

5

25.0

3

35.0

2

 

OLFLEX CLASSIC 110 CY

 

VDE registered 300/500 V screened control cable with transparent outer sheath. G = includes green-yellow protective earth core; X = without green-yellow core.

 

Part No.

Cores × mm²

AWG

Outer Diameter (mm)

Copper Index (kg/km)

Total Weight (kg/km)

1135752

2 X 0.5

20

7.0

41.0

75

1135753

3 X 0.5

20

7.3

45.5

83

1135007

7 G 0.5

20

8.9

80.5

132

1135012

12 G 0.5

20

11.3

138.5

202

1135754

4 X 0.5

20

7.9

55.0

99

1135025

25 G 0.5

20

15.2

250.0

378

1135802

2 X 0.75

18

7.4

46.0

86

1135104

4 G 0.75

18

8.4

64.0

115

1135105

5 G 0.75

18

8.9

77.4

130

1135103

3 G 0.75

18

7.9

57.9

100

1135112

12 G 0.75

18

12.3

177.0

247

1135852

2 X 1

17

7.9

56.0

98

1135203

3 G 1

17

8.2

65.3

111

1135204

4 G 1

17

8.7

78.1

130

1135854

4 X 1

17

8.7

78.1

130

1135207

7 G 1

17

10.2

113.3

185

Part No.

Cores × mm²

AWG

Outer Diameter (mm)

Copper Index (kg/km)

Total Weight (kg/km)

1135218

18 G 1

17

15.5

286.0

418

1135303

3 G 1.5

15

8.9

83.0

136

1135304

4 G 1.5

15

9.6

100.0

163

1135904

4 X 1.5

15

9.6

100.0

163

1135305

5 G 1.5

15

10.3

125.0

188

1135307

7 G 1.5

15

11.3

149.0

237

1135312

12 G 1.5

15

14.8

280.0

393

1135403

3 G 2.5

13

10.3

146.0

192

1135404

4 G 2.5

13

11.3

167.0

233

1135504

4 G 4

11

13.4

237.0

347

1135604

4 G 6

9

15.8

318.0

485

1135614

4 G 10

7

19.0

518.0

735

1135624

4 G 16

5

22.2

804.0

1395

1135626

4 G 25

3

26.9

1161.0

1730

1135625

4 G 35

2

30.2

1543.0

2210

           

 

Send Inquiry