Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex classic 110 cy control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Lead Paragraph
OLFLEX CLASSIC 110 CY is the double-sheathed, screened PVC control cable for electrically noisy industrial environments where signal integrity and interference immunity are critical. A high-density tinned copper braid over a robust grey PVC inner sheath, beneath a transparent outer jacket, delivers certified EMC performance with transfer impedance below 250 Ω/km at 30 MHz. Unlike unshielded control lines that pick up switching spikes, or light-screened types lacking inner bedding, it isolates sensitive 300/500 V control, measurement and sensor loops running parallel to variable frequency drives and heavy switchgear. The cable series carries VDE registration no. 7030, and every length is spark-tested at 4000 V. KABASI supplies cut-to-length bulk cable or completed harnesses fitted with 360° EMC glands and multi-pole connectors.
Select Your Variant
Protective Earth vs. Clean Measurement Ground (G vs. X)
|
Configuration |
Designation Format |
Internal Identification |
Best Practice Application |
|
G (With Protective Conductor) |
e.g. 4 G 1.5, 7 G 0.75, 12 G 1 |
Includes 1 green-yellow core + consecutively numbered black cores |
Standard choice for machinery control, motor auxiliary circuits, interlocks, and push-button stations requiring equipment chassis PE bond. |
|
X (Without Protective Conductor) |
e.g. 2 X 0.75, 4 X 1, 12 X 0.5 |
Only black cores with white consecutive numbers; zero green-yellow |
Preferred for clean DC control circuits, isolated measurement bridges, two-wire 4–20 mA instrumentation, or where PE must not enter the signal bundle. |
Structural Comparison: CLASSIC 110 CY vs. Sibling Control Cables
|
Cable Model |
Shielding Architecture |
Inner Sheath |
Outer Sheath Style |
Primary Engineering Intent |
|
OLFLEX CLASSIC 110 CY |
Tinned copper braid (Z_T ≤ 250 Ω/km) |
Grey PVC bedding layer |
Transparent clear PVC |
EMC interference immunity with visual braid inspection for control/drive environments. |
|
OLFLEX CLASSIC 110 (Unshielded) |
None |
None |
Silver-grey or black PVC |
Cost-effective, highly flexible control cabling where EMC cross-talk is absent. |
|
OLFLEX CLASSIC 115 CY |
Tinned copper braid |
None (wrap over cores) |
Silver-grey PVC |
Ultra-compact outer diameter where tight installation space outweighs mechanical crush protection. |
|
OLFLEX CLASSIC 110 SY |
Galvanized steel wire braid (SY) |
Grey PVC bedding layer |
Transparent clear PVC |
Severe mechanical crush, gouge, and rodent protection on factory floor pathways. |
Typical Applications




Why Choose OLFLEX CLASSIC 110 CY Series
|
Advantage |
What it means on site |
|
True Double-Sheath Construction Protects Core Insulation |
Unlike single-sheathed screened cables where the metallic braid sits directly against insulated cores, CLASSIC 110 CY incorporates a robust grey PVC inner jacket. This provides mechanical cushioning under gland compression and ensures the tinned copper braid never abrades or punctures core insulation during flexing. |
|
Verified Transfer Impedance (≤ 250 Ω/km at 30 MHz) |
High-speed PWM drives and servo choppers radiate intense interference between 1 MHz and 30 MHz. By guaranteeing transfer impedance below 250 Ω/km, CLASSIC 110 CY prevents control channel corruption, eliminating the phantom fault trips common with unverified generic cables. |
|
Transparent Jacket for Zero-Downtime Inspection |
The clear PVC formulation allows maintenance personnel to inspect shield continuity, braid density, and spot mechanical pinching or internal water ingress instantly without slitting or removing outer insulation. |
|
4000 V Proof Test & Full VDE Quality Auditing |
Tested at four times the rated operational voltage (4 kV AC) and covered by the cable series' VDE registration no. 7030, this series delivers zero dielectric defect leakage for continuous operation in automated production environments. |
Frequently Asked Questions
Q: Why choose CLASSIC 110 CY instead of the thinner CLASSIC 115 CY?
A: CLASSIC 110 CY features an extruded grey PVC inner sheath beneath the copper braid, whereas 115 CY omits the inner sheath to achieve minimum outer diameter. Choose 110 CY when cables undergo frequent mechanical clamping, gland compression, or vibration, because the inner jacket prevents braid strands from penetrating core insulation. Choose 115 CY only when cabinet volume is severely restricted.
Q: What is the advantage of a transparent outer sheath on a screened cable?
A: Transparency enables instant visual verification of shield integrity without stripping or damaging the cable. Field engineers can quickly detect braid unraveling, chemical oxidation, severe bend kinks, or moisture penetration during routine visual audits, avoiding unexpected production outages.
Q: Should the braid be landed with a 360° clamp or a twisted pigtail?
A: A 360° clamp is the better landing for screened cable: the braid is bonded around its full circumference, so the screen stays a low-impedance path at high frequency. A twisted pigtail leaves most of the braid unconnected and puts inductance exactly where the screen meets earth. Neither method is part of the cable; it is how the screen is landed at the gland or the clamp.
Q: What is the operational difference between G and X part numbers?
A: Rows designated with G include a green-yellow protective earth (PE) grounding conductor. Rows designated with X have solely black numbered cores without green-yellow. In screened cables, G is standard for machinery and interlocks, while X is favored for clean isolated instrumentation loops where PE loop loops must be avoided.
Q: Can KABASI supply pre-terminated CLASSIC 110 CY assemblies with EMC glands?
A: Yes. KABASI operates precision stripping, braided screen combing, and automated terminal crimping production lines. We deliver complete custom harnesses pre-fitted with IP68 EMC brass glands, heavy-duty connectors, and custom wire pinouts ready for direct machine drop-in.
Hot Tags: olflex classic 110 cy control cable, China olflex classic 110 cy control cable suppliers
Electrical & Mechanical Performance Data
|
Parameter |
Specification Standard / Technical Value |
|
Conductor Construction |
Fine-wire bare copper conductor strands according to VDE 0295 Class 5 / IEC 60228 Class 5 |
|
Core Insulation |
Special PVC compound LAPP P8/1; optimal dielectric breakdown strength |
|
Core Identification |
Black cores with white consecutive Arabic numerals per VDE 0293-1; optional green-yellow earth (G) |
|
Inner Sheath (Bedding) |
Lead-free PVC compound, grey; cushions core bundle and provides uniform cylindrical braid seat |
|
Screening / Braid |
Tinned copper wire braided shield; high optical coverage and low transfer impedance |
|
Outer Sheath |
Special transparent PVC compound; flame retardant to IEC 60332-1-2 |
|
Rated Voltage (U₀/U) |
300/500 V |
|
Dielectric Test Voltage |
4000 V AC (spark tested for high insulation reliability) |
|
Transfer Impedance |
Maximum 250 Ω/km at 30 MHz per transfer measurement method |
|
Minimum Bending Radius |
Occasional flexing: 20 × cable outer diameter | Fixed installation: 6 × cable outer diameter |
|
Temperature Range |
Occasional flexing: −5 °C to +70 °C | Fixed installation: −40 °C to +80 °C |
|
Flame Retardancy |
Flame-retardant according to IEC 60332-1-2 (vertical single-wire flame test) |
|
Chemical Resistance |
Good resistance against light industrial oils, dilute acids, and alkaline solutions |
|
Standard Packaging |
Coils up to 30 kg / 250 m; wooden or steel drums above that threshold |
EMC Transfer Impedance & Screening Efficiency
Electromagnetic shielding in an industrial control cabinet cannot be assessed by visual braid coverage alone; high-frequency interference immunity is governed by transfer impedance (Z_T). OLFLEX CLASSIC 110 CY is manufactured to an engineered transfer impedance ceiling of ≤ 250 Ω/km at 30 MHz to guarantee active noise suppression across switching harmonics.
|
Noise Frequency Band |
Primary Industrial Source |
CLASSIC 110 CY Protection Mechanism |
Practical Field Outcome |
|
10 kHz – 150 kHz (Conducted Low-Freq) |
SCR heating controllers, line power harmonics, heavy motor starters |
Closed copper mass density minimizes low-frequency inductive cross-coupling |
Eliminates 50/60 Hz hum and slow sensor zero-drift in analog process channels |
|
150 kHz – 30 MHz (HF Commutation) |
VFD pulse-width modulation (PWM) carrier frequencies, servo inverter spikes |
Optimized braid weave angle achieves transfer impedance ≤ 250 Ω/km at 30 MHz benchmark |
Prevents digital I/O false triggers and relay chatter in runs parallel to drive cables |
|
30 MHz – 100 MHz (VHF Radiated) |
Relay coil arc discharge, contactor bounce, unsuppressed solenoid kicks |
Tinned copper braid coverage blocks radiated RF intrusion through cabinet entryways |
Guarantees encoder count accuracy and PLC communication bus integrity without packet drops |
The transparent PVC outer jacket provides continuous visual verification of the braid condition: any installation pinch, mechanical crushing, chemical corrosion, or braid unraveling can be identified during routine maintenance without cutting the cable jacket open.
Termination & 360° Shield-Bonding Practice
An EMC-screened cable is only as effective as its ground termination. Pigtailing the braided screen into a thin wire terminal compromises high-frequency shielding due to localized inductance. Follow these industrial termination rules for OLFLEX CLASSIC 110 CY:
|
Termination Technique |
EMC Performance at >10 MHz |
Recommended Hardware |
Critical Installation Step |
|
360° Circumferential EMC Cable Gland |
Optimal (95–99% effectiveness) |
Brass EMC gland with contact springs |
Strip transparent outer sheath by 15–20 mm; seat internal grounding springs directly onto the exposed tinned copper braid. |
|
EMC Saddle Clamp on Ground Busbar |
High (80–90% effectiveness) |
C-rail copper spring saddle or earthing clip |
Strip only the transparent outer jacket over the clamp zone; torque saddle directly over the braid to a copper earth rail. |
|
Twisted Pigtail Ground (Not Recommended) |
Severe degradation (<30% effectiveness) |
Ground lug crimped on twisted braid tail |
Never use pigtails on VFD motor or encoder lines; inductive choke creates high-frequency ground bounce inside the cabinet. |
The grey PVC inner sheath prevents the braid from biting into individual core insulation during tight cable gland tightening, safeguarding against core-to-shield short circuits under mechanical vibration.
Metric to AWG Reference Notice
All cable dimensions and core structures on this page are manufactured strictly to IEC 60228 metric units. The table below provides nominal area equivalence for North American electrical drawings. Specify the metric part number on formal purchase orders to prevent dimensional mismatch.
|
Metric Section (mm²) |
Approximate AWG Equivalent |
|
0.5 |
20 |
|
0.75 |
18 |
|
1.0 |
17 |
|
1.5 |
15 |
|
2.5 |
13 |
|
4.0 |
11 |
|
6.0 |
9 |
|
10.0 |
7 |
|
16.0 |
5 |
|
25.0 |
3 |
|
35.0 |
2 |
OLFLEX CLASSIC 110 CY
VDE registered 300/500 V screened control cable with transparent outer sheath. G = includes green-yellow protective earth core; X = without green-yellow core.
|
Part No. |
Cores × mm² |
AWG |
Outer Diameter (mm) |
Copper Index (kg/km) |
Total Weight (kg/km) |
|
1135752 |
2 X 0.5 |
20 |
7.0 |
41.0 |
75 |
|
1135753 |
3 X 0.5 |
20 |
7.3 |
45.5 |
83 |
|
1135007 |
7 G 0.5 |
20 |
8.9 |
80.5 |
132 |
|
1135012 |
12 G 0.5 |
20 |
11.3 |
138.5 |
202 |
|
1135754 |
4 X 0.5 |
20 |
7.9 |
55.0 |
99 |
|
1135025 |
25 G 0.5 |
20 |
15.2 |
250.0 |
378 |
|
1135802 |
2 X 0.75 |
18 |
7.4 |
46.0 |
86 |
|
1135104 |
4 G 0.75 |
18 |
8.4 |
64.0 |
115 |
|
1135105 |
5 G 0.75 |
18 |
8.9 |
77.4 |
130 |
|
1135103 |
3 G 0.75 |
18 |
7.9 |
57.9 |
100 |
|
1135112 |
12 G 0.75 |
18 |
12.3 |
177.0 |
247 |
|
1135852 |
2 X 1 |
17 |
7.9 |
56.0 |
98 |
|
1135203 |
3 G 1 |
17 |
8.2 |
65.3 |
111 |
|
1135204 |
4 G 1 |
17 |
8.7 |
78.1 |
130 |
|
1135854 |
4 X 1 |
17 |
8.7 |
78.1 |
130 |
|
1135207 |
7 G 1 |
17 |
10.2 |
113.3 |
185 |
|
Part No. |
Cores × mm² |
AWG |
Outer Diameter (mm) |
Copper Index (kg/km) |
Total Weight (kg/km) |
|
1135218 |
18 G 1 |
17 |
15.5 |
286.0 |
418 |
|
1135303 |
3 G 1.5 |
15 |
8.9 |
83.0 |
136 |
|
1135304 |
4 G 1.5 |
15 |
9.6 |
100.0 |
163 |
|
1135904 |
4 X 1.5 |
15 |
9.6 |
100.0 |
163 |
|
1135305 |
5 G 1.5 |
15 |
10.3 |
125.0 |
188 |
|
1135307 |
7 G 1.5 |
15 |
11.3 |
149.0 |
237 |
|
1135312 |
12 G 1.5 |
15 |
14.8 |
280.0 |
393 |
|
1135403 |
3 G 2.5 |
13 |
10.3 |
146.0 |
192 |
|
1135404 |
4 G 2.5 |
13 |
11.3 |
167.0 |
233 |
|
1135504 |
4 G 4 |
11 |
13.4 |
237.0 |
347 |
|
1135604 |
4 G 6 |
9 |
15.8 |
318.0 |
485 |
|
1135614 |
4 G 10 |
7 |
19.0 |
518.0 |
735 |
|
1135624 |
4 G 16 |
5 |
22.2 |
804.0 |
1395 |
|
1135626 |
4 G 25 |
3 |
26.9 |
1161.0 |
1730 |
|
1135625 |
4 G 35 |
2 |
30.2 |
1543.0 |
2210 |