OLFLEX CLASSIC 110 Control Cable

OLFLEX CLASSIC 110 Control Cable
Details:
OLFLEX CLASSIC 110 oil-resistant control cable: numbered cores to VDE 0293-1, 300/500 V, 4 kV tested. Compare the 110 BK black UV-resistant sheath version.

Standards & Compliance
VDE 0293-1 | VDE 0295 / IEC 60228 Class 5 | DIN EN 50290-2-22 (TM 54) | IEC 60332-1-2 | ISO 4892-2 (110 BK)

Quick Specs
300/500 V | 4000 V test | 0.5-120 mm² (110) / 0.5-35 mm² (BK) | −15 to +70 °C occasional flex | 10 × OD flex, drag chain to 5 m
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex classic 110 control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

OLFLEX CLASSIC 110 is the 300/500 V PVC control cable machine builders reach for when cores must stay identifiable in a crowded panel: black cores with white numbers to VDE 0293-1, Class 5 fine-wire bare copper, and a grey sheath that resists oil to DIN EN 50290-2-22 (TM 54). The black-sheath CLASSIC 110 BK keeps that construction and adds UV and weather resistance to ISO 4892-2 for outdoor runs and nacelle looms. Both are 4 kV tested and rated for fixed installation, occasional flexing and power chains up to 5 m travel - not continuous drag-chain duty. Cross-sections run 0.5–120 mm² in grey and 0.5–35 mm² in black, and both can be cut, terminated and delivered as finished assemblies.

 

Select Your Variant

 

By Sheath and Rating

Parameter

CLASSIC 110

CLASSIC 110 BK

Sheath colour

Grey PVC ≈ RAL 7001

Black PVC ≈ RAL 9005

Oil resistance

DIN EN 50290-2-22 (TM 54)

DIN EN 50290-2-22 (TM 54)

UV / weather

Not rated

ISO 4892-2

Cross-section range

0.5 – 120 mm²

0.5 – 35 mm²

Typical destination

Panel interiors, machine tools, plant rooms

Outdoor cabinets, nacelles, exposed trays

 

By Installation Requirement

Requirement

Recommended Variant

Why

Panel and machine wiring, oil or coolant present

CLASSIC 110

Oil resistance to DIN EN 50290-2-22 (TM 54) is the deciding property indoors

Outdoor, UV exposure, weather-facing runs

CLASSIC 110 BK

ISO 4892-2 covers sunlight and weathering; the grey sheath is not rated for it

Power chain with travel up to 5 m

Either

0.5–2.5 mm², 2–7 cores, 200,000 to 1,000,000 bending cycles

Torsion in a wind turbine jumper loop

Either

TW-0 and TW-1 ratings, ±150°/m

Continuous drag chain, long travel, high speed

Neither

Specify a dedicated drag-chain cable for that duty

 

Typical Applications

 

01fixed-installation-with-occasional-bending-control-cabinet-beside-a-mesh-safety-gate-wired-with-fixed-runs-in-an-industrial-hall

Fixed installation with occasional bending
Fixed runs bend at 4 × OD and occasional movement at 10 × OD, so one cable covers the panel and the guard beside it.

02power-chains-up-to-5-m-travel-cable-carrier-energy-chain-on-the-linear-axis-of-a-cnc-machining-centre-under-the-spindle

Power chains up to 5 m travel
In a power chain it is rated to 5 m travel at 0.5–2.5 mm² and 2–7 cores, 200,000 to 1,000,000 cycles - short axes do not need a separate drag-chain cable.

03torsion-rated-wind-turbine-jumper-area-blue-jumper-cables-looping-around-the-nacelle-hub-between-the-blade-roots-and-the-generator

Torsion - wind turbine jumper areas
For WTG jumper loops it carries TW-0 to 5,000 cycles at ±150°/m and TW-1 down to −20 °C at 2,000.

04indoor-and-outdoor-use-distribution-panels-inside-the-hall-with-cable-ladders-running-out-to-an-outdoor-tray-in-direct-sunlight

Indoor and outdoor use    (CLASSIC 110 BK)
The BK build adds UV and weathering to ISO 4892-2, so the same construction goes from the panel room to an outdoor tray.

 

Why Choose OLFLEX CLASSIC 110 Series

 

Advantage

What it means on site

Oil Resistance That Holds Where Standard PVC Fails Early

The grey sheath is rated to DIN EN 50290-2-22 (TM 54), the test that separates this cable from ordinary PVC control cable in a machine tool or a hydraulic-adjacent enclosure. Cable that has swollen or gone tacky after a year of oil contact is usually the reason a panel is rewired; this construction is specified so that rewiring does not happen.

Numbered Cores Stay Readable Past Thirty Core

Cores are black with white numbers printed to VDE 0293-1, including high core counts where colour coding runs out of distinct combinations. A fitter reads the number rather than tracing continuity, which shortens termination and removes the most common source of miswiring on multi-core control cable.

Rated for Short Power Chains, Not Just Static Runs

At 0.5–2.5 mm² and 2–7 cores the cable carries a power-chain rating for travel up to 5 m, with 200,000 to 1,000,000 bending cycles depending on the cross-section. Short moving axes and indexing tables sit inside that envelope; anything longer, faster or continuously cycling needs a dedicated drag-chain cable.

A Black Sheath for the Runs That Face Weather

CLASSIC 110 BK carries the same construction under a black PVC sheath tested to ISO 4892-2 for UV and weathering, so outdoor cabinets, nacelle looms and exposed trays can be wired from the same specification family as the indoor panels. One cable family across both locations means one set of termination practices and one spare-cable stock.

 

Frequently Asked Questions

 

Q: What do G and X mean in the designation?

A: Two letters, two configurations. A part number carrying G includes a green-yellow protective conductor in the lay-up; X is built without it. Because that conductor occupies a position that a numbered core would otherwise hold, a G row and an X row of the same size share the same outer diameter; copper weight and total weight can differ between the two builds. Where a size in the list carries only one letter, that is the stock build; the other can be quoted against an order.

Q: Can this cable be used in a continuous drag chain?

A: No. The power-chain rating applies to travel up to 5 m at 0.5–2.5 mm² and 2–7 cores, with a defined bending-cycle limit. Longer travel, higher speed, or continuous cycling requires a cable designed for that duty. Send the travel distance, cycle rate and cross-section and we will confirm whether this construction is within range or recommend the appropriate drag-chain alternative.

Q: How do the grey and black sheath versions differ?

A: The construction beneath the sheath is identical: Class 5 copper, PVC insulation, numbered black cores, 4 kV test voltage, 300/500 V. What changes is the outer sheath and what it is rated for. The grey version carries the oil-resistance rating and covers 0.5 to 120 mm². The black version retains the oil rating, adds UV and weathering resistance to ISO 4892-2, but its cross-section range stops at 35 mm². The choice turns on the route environment rather than the core count.

Q: Is it suitable for nacelle torsion loops?

A: Yes. Two published ratings cover WTG jumper sections: TW-0 above +5 °C at ±150°/m for 5000 cycles, and TW-1 down to −20 °C at the same angle for 2000 cycles. Dress the loop as a radius arc rather than a tight kink so the twist distributes along the cable rather than concentrating at the gland entry.

Q: Is the cable oil resistant?

A:Both sheath versions are rated to DIN EN 50290-2-22 (TM 54) and offer good chemical resistance at room temperature. The sheath compound is the variable - way oil, coolant and hydraulic fluid behave differently on PVC. Tell us the fluid involved and we will confirm whether the standard sheath is suitable or a different compound is needed.

Q: How tight can the cable be bent?

A: Fixed installation: 4 × OD. Occasional flexing: 10 × OD. Power chain: 15 × OD. In practice the limiting bend is usually the one at the gland entry or the duct corner, not the one mid-run - measure the tightest point on the route before pulling the cable.

 

 

Hot Tags: olflex classic 110 control cable, China olflex classic 110 control cable suppliers

Common Specifications - Both Variants

 

Parameter

Value

Nominal Voltage

300/500 V (U₀/U)

Test Voltage

4000 V

Conductor

Class 5 fine-wire bare copper (VDE 0295 / IEC 60228 Class 5)

Insulation

PVC

Core Identification

Black cores with white numbers (VDE 0293-1)

Protective Conductor

G = green-yellow earth core included; X = no earth core

Temperature - Fixed

−40 °C to +80 °C

Temperature - Occasional Flexing

−15 °C to +70 °C

Temperature - Power Chain

−5 °C to +70 °C

Min. Bending Radius - Fixed

4 × OD

Min. Bending Radius - Occasional Flexing

10 × OD

Min. Bending Radius - Power Chain

15 × OD

Oil Resistance

DIN EN 50290-2-22 (TM 54)

Flame Retardancy

IEC 60332-1-2

Torsion Rating

TW-0: ≥ +5 °C, ±150°/m, 5000 cycles; TW-1: ≥ −20 °C, ±150°/m, 2000 cycles

Drag-Chain Rating

Travel ≤ 5 m; 0.5–2.5 mm², 2–7 cores; 200,000 to 1,000,000 bending cycles

Chemical Resistance

Good chemical resistance

 

Construction and Core Identification

 

Parameter

CLASSIC 110

CLASSIC 110 BK

Sheath

Grey PVC ≈ RAL 7001

Black PVC ≈ RAL 9005

UV / Weather Resistance

Not rated

ISO 4892-2

Temp. - Occasional Flexing

−15 °C to +70 °C

−15 °C to +70 °C

Cross-Section Range

0.5 – 120 mm²

0.5 – 35 mm²

Additional Standards

None

ISO 4892-2

Standards applied

VDE 0293-1 / IEC 60228 / DIN EN 50290-2-22 /IEC 60332-1-2

IEC 60332-1-2 / DIN EN 50290-2-22 / ISO 4892-2

 

OLFLEX CLASSIC 110

 

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

1119752

2×0.5

20

4.8

9.6

35

1119003

3G0.5

20

5.1

14.4

42

1119753

3×0.5

20

5.1

14.4

42

1119004

4G0.5

20

5.7

19.2

54

1119754

4×0.5

20

5.7

19.2

54

1119005

5G0.5

20

6.2

24.0

63

1119755

5×0.5

20

6.2

24.0

63

1119007

7G0.5

20

6.7

33.6

73

1119757

7×0.5

20

6.7

33.6

81

1119012

12G0.5

20

8.9

58.0

131

1119014

14G0.5

20

9.5

67.0

153

1119018

18G0.5

20

10.5

86.4

188

1119021

21G0.5

20

11.7

101.0

221

1119025

25G0.5

20

12.4

120.0

261

1119030

30G0.5

20

13.3

144.0

304

1119035

35G0.5

20

14.5

168.0

356

1119802

2×0.75

18

5.4

14.4

45

1119103

3G0.75

18

5.7

21.6

55

1119112

12G0.75

18

9.9

86.0

171

1119855

5×1

17

7.1

48.0

94

1119857

7×1

17

8.0

67.0

126

1119208

8G1

17

9.5

77.0

149

1119210

10G1

17

10.2

96.0

180

1119862

12×1

17

10.5

115.0

205

1119216

16G1

17

11.8

153.6

266

1119868

18×1

17

12.7

173.0

320

1119225

25G1

17

14.7

240.0

408

1119303

3G1.5

15

6.7

43.0

84

1119304

4G1.5

15

7.2

58.0

104

1119305

5G1.5

15

8.1

72.0

128

1119307

7G1.5

15

8.9

101.0

166

1119308

8G1.5

15

10.6

115.0

210

1119309

9G1.5

15

11.4

130.0

221

1119116

16G0.75

18

11.1

115.2

220

1119125

25G0.75

18

13.8

180.0

337

1119852

2×1

17

5.7

19.2

53

1119853

3×1

17

6.0

28.8

65

1119205

5G1

17

7.1

48.0

94

1119803

3×0.75

18

5.7

21.6

55

1119104

4G0.75

18

6.2

28.8

66

1119804

4×0.75

18

6.2

28.8

66

1119105

5G0.75

18

6.7

36.0

79

1119805

5×0.75

18

6.7

36.0

79

1119107

7G0.75

18

7.3

50.0

101

1119807

7×0.75

18

7.3

50.0

101

1119109

9G0.75

18

9.4

65.0

137

1119110

10G0.75

18

9.6

72.0

150

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

1119854

4×1

17

6.5

38.4

79

1119206

6G1

17

8.0

58.0

113

1119207

7G1

17

8.0

67.0

126

1119209

9G1

17

10.0

86.0

164

1119212

12G1

17

10.5

115.0

205

1119214

14G1

17

11.2

134.0

238

1119218

18G1

17

12.7

173.0

320

1119220

20G1

17

13.4

192.0

330

1119902

2×1.5

15

6.3

29.0

68

1119903

3×1.5

15

6.7

43.0

84

1119904

4×1.5

15

7.2

58.0

104

1119905

5×1.5

15

8.1

72.0

128

1119907

7×1.5

15

8.9

101.0

166

1119313

8×1.5

15

10.6

116.0

210

1119812

12×0.75

18

9.9

86.0

171

1119121

21G0.75

18

13.0

151.0

286

1119134

34G0.75

18

15.9

245.0

448

1119203

3G1

17

6.0

28.8

65

1119204

4G1

17

6.5

38.4

65

1119310

10G1.5

15

11.6

143.0

243

1119312

12G1.5

15

12.0

173.0

279

1119318

18G1.5

15

14.4

259.0

407

1119325

25G1.5

15

16.9

360.0

560

1119952

2×2.5

13

7.5

48.0

101

1119403

3G2.5

13

8.1

72.0

132

1119404

4G2.5

13

8.9

96.0

163

1119405

5G2.5

13

10.0

120.0

200

1119407

7G2.5

13

11.1

168.0

267

1119412

12G2.5

13

14.8

288.0

445

1119425

25G2.5

13

20.8

600.0

890

1119503

3G4

11

9.9

115.0

201

1119504

4G4

11

10.8

154.0

249

1119505

5G4

11

12.1

192.0

294

1119507

7G4

11

13.4

269.0

407

1119603

3G6

9

11.7

172.8

289

1119604

4G6

9

13.0

230.0

365

1119605

5G6

9

14.5

288.0

447

1119613

3G10

7

14.6

288.0

466

1119614

4G10

7

16.2

384.0

590

1119615

5G10

7

18.1

480.0

722

1119624

4G16

5

18.8

614.0

1087

1119625

5G16

5

21.2

768.0

1370

1119634

4G25

3

23.5

960.0

1582

1119635

5G25

3

26.4

1200

1998

1119644

4G35

2

26.4

1344

2106

1119645

5G35

2

29.6

1680

2635

           

 

Send Inquiry