OLFLEX 191 Control Cable

OLFLEX 191 Control Cable
Details:
OLFLEX 191 multi-standard flexible PVC control cable: dual-certified UL AWM Style 21098 (600V/90°C) and CSA AWM I/II A/B, oil-resistant to EN 50363-4-1 (TM5), 4 kV test voltage, for machine tool export.

Standards & Compliance
UL AWM Style 21098 (600V, 90°C) | CSA AWM I A/B II A/B | IEC 60228 / VDE 0295 Class 5 | EN 50363-4-1 (TM5 Oil) | IEC 60332-1-2 / UL 1581 §1061

Quick Specs
300/500 V (UL/CSA 600 V) | 4000 V AC test | 0.5 – 120 mm², 2 – 34 cores | −40 °C to +70 °C fixed | Dual-certified UL AWM Style 21098 / CSA AWM I A/B II A/B
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex 191 control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

OLFLEX 191 is the multi-standard, oil-resistant flexible PVC control cable for OEMs exporting automated machinery to North America and Europe. It holds dual recognition under UL AWM Style 21098 (600 V, 90 °C) and CSA AWM I A/B II A/B, so a single unshielded multi-conductor design satisfies both IEC machine standards and NFPA 79 wiring rules. The silver-grey sheath is formulated to EN 50363-4-1 (TM5), giving long-term immunity to mineral oils, cutting emulsions and synthetic coolants in CNC beds and transfer lines. Conductors span 0.5 mm² (20 AWG) to 120 mm² (4/0 AWG) with a 4000 V factory dielectric test, bridging control signalling and motor connection. KABASI supplies full reels or pre-cut assemblies with industrial pinouts.

 

Select Your Variant

 

OLFLEX 191 (Unshielded) vs. OLFLEX 191 CY (Screened)

Engineering Selection Criterion

OLFLEX 191 (Unshielded)

OLFLEX 191 CY (Screened with Braid)

Practical Selection Recommendation

Electromagnetic Shielding

None (bare core lay-up under outer jacket)

Tinned copper wire braided screen (transfer impedance ≤ 250 Ω/km @ 30 MHz)

Specify 191 for standard control circuits, pushbuttons, and auxiliary lines; specify 191 CY where signals run alongside variable frequency drives (VFDs).

Space & Bend Radius

Smaller outer diameter (e.g. 4 G 1.5 is 8.1 mm); tighter bend (15 × OD flex)

Larger diameter (e.g. 4 G 1.5 is 10.1 mm); stiffer bend (20 × OD flex)

Choose unshielded 191 where wire ducts are densely packed and electromagnetic interference is isolated.

Weight & Termination Cost

Lightweight (4 G 1.5 weighs 112 kg/km); rapid stripping

Heavier (4 G 1.5 weighs 191 kg/km); needs a 360° shield clamp at termination

Unshielded 191 dramatically reduces field termination labor when EMC shielding is not technically required.

Dual UL/CSA Approval

Both carry UL AWM Style 21098 and CSA AWM I/II A/B

Both carry UL AWM Style 21098 and CSA AWM I/II A/B

Full North American export compliance is identical across both product families.

 

Typical Applications

 

01row-of-cnc-machining-centres-with-a-workpiece-clamped-on-the-table-and-control-panels-along-the-aisle

Machine Tools and Metalworking
A machine tool runs control, axis and cooling circuits from one cable family, so a frame does not need a different cable at every panel. The same sheath works for the European and the North American machine market, which keeps one bill of materials on an export build.

02two-open-control-cabinet-doors-showing-breakers-contactors-terminal-blocks-and-a-display-panel-in-a-workshop

Plant Engineering and Industrial Machinery
Plant wiring is fixed and clamped, with only guards and tool changes moving the cable, and the bend ratings are set for exactly that split. Panel and frame are wired from the same construction, so nothing changes at the cabinet wall.

03rotary-limit-switch-with-a-roller-lever-and-a-24-v-ac-dc-rating-shown-as-a-product-shot-on-a-white-background

Heating and Air-Conditioning Systems
Plant-room conditions stay inside the fixed temperature range, and the numbered cores let a fan or damper circuit be picked out at the terminal. Sensors, damper actuators and fan contactors share the same control cores.

04oil-water-separator-unit-with-a-stainless-tank-air-diaphragm-pump-and-hose-connections-in-a-workshop

Dry and Damp Interiors, Including Oil-Water Mixtures
Dry and damp interiors, oil-water mixtures included, are inside the rated environment, and the sheath is oil resistant. It is an indoor cable, and outdoor installation is not covered.

 

Why Choose OLFLEX 191 Series

 

Advantage

What it means on site

True Global Export Compliance with UL AWM 21098 & CSA Approval

Eliminates the logistical nightmare of maintaining dual machine inventories for North America and Europe. Build one machine with OLFLEX 191 and export worldwide with full NFPA 79 code acceptance.

TM5 Oil Resistance for Machine Tool Longevity

Formulated to withstand daily exposure to mineral oils, hydraulic fluids, and synthetic cutting emulsions without jacket swelling, softening, or embrittlement in harsh manufacturing environments.

Heavy Conductor Range from 0.5 mm² Up to 120 mm²

Spans from delicate 0.5 mm² multi-core control lines all the way to massive 120 mm² main incoming power feeders, allowing complete plant electrical installations from a single unified cable family.

Proven 4000 V Test Voltage Delivers Superior Electrical Reliability

Tested at 4000 V, providing exceptional dielectric withstand safety against switching transients, inductive spikes, and heavy industrial electrical noise.

 

Frequently Asked Questions

 

Q: Can OLFLEX 191 be used in industrial machinery exported to the USA under NFPA 79?

A: Yes. OLFLEX 191 carries UL AWM Style 21098 and CSA AWM I/II A/B recognition (600 V, 90 °C). In accordance with NFPA 79 (Electrical Standard for Industrial Machinery) section 12.2.7.3, AWM cables are approved for factory-wired industrial machines when installed in compliance with manufacturer specifications.

Q: What is the practical difference between OLFLEX 191 and OLFLEX 191 CY?

A: OLFLEX 191 is an unshielded cable designed for general control, power, and auxiliary circuits where electromagnetic interference is minimal or contained. OLFLEX 191 CY features an additional tinned copper wire braided screen (transfer impedance ≤ 250 Ω/km at 30 MHz) beneath the outer sheath to shield sensitive analog signals from VFD and motor drive electrical noise.

Q: Why is OLFLEX 191 rated at 300/500 V under IEC but 600 V under UL/CSA?

A: European (IEC) standards evaluate nominal line-to-earth and line-to-line operating voltages (300/500 V), whereas North American (UL/CSA) appliance wiring material standards rate dielectric withstand based on 600 V insulation test protocols. The cable construction meets both standards simultaneously, allowing safe operation on 400 V European and 480 V North American machine circuits.

Q: Can OLFLEX 191 be installed outdoors in open sunlight?

A: No. OLFLEX 191 is engineered specifically for dry, damp, and wet industrial interiors, including areas with oil-water mixtures. The standard grey PVC jacket is not UV-stabilized for direct outdoor sun exposure. For outdoor or all-weather applications requiring oil and weather resistance, specify OLFLEX ROBUST 200 or OLFLEX CLASSIC 110 BLACK.

Q: How does the TM5 oil resistance of OLFLEX 191 compare to standard PVC control cables?

A: Standard PVC cables undergo significant swelling, softening, and plasticizer leaching when exposed to cutting fluids and mineral oils, leading to jacket splits. OLFLEX 191 is tested according to EN 50363-4-1 (TM5), ensuring strict limits on oil absorption and elongation loss, thereby dramatically extending service life inside CNC machinery.

 

 

Hot Tags: olflex 191 control cable, China olflex 191 control cable suppliers

Electrical, Mechanical & Environmental Ratings

 

Technical Parameter

Standard Reference & Certified Value

Conductor Stranding

Class 5 fine-wire bare copper conductor strands according to VDE 0295 / IEC 60228

Core Insulation

PVC insulation

Core Identification

Black cores with consecutive white Arabic numbers (VDE 0293-1); G version contains green-yellow earth in outer layer

Core Lay-Up

Cores stranded in layers

Outer Sheath Material

grey, similar to RAL 7001

Nominal Operating Voltage (U₀/U)

IEC: 300/500 V | UL/CSA: 600 V

Dielectric Test Voltage

4000 V test voltage.

Minimum Bending Radius

Occasional flexing: 15 × cable outer diameter | Fixed installation: 4 × cable outer diameter

Temperature Range (IEC)

Occasional flexing: −5 °C to +70 °C | Fixed installation: −40 °C to +70 °C

Temperature Range (UL/CSA)

Operating temperature up to +90 °C (dry rating for AWM Style 21098)

Oil Resistance Standard

EN 50363-4-1: TM5 (tested against standard industrial mineral oils and cutting fluids)

Flame Retardance Compliance

IEC 60332-1-2, UL 1581 §1061 Cable Flame Test

Environmental Restriction

Mainly for dry, damp, and wet interiors (including water-oil mixtures); not intended for outdoor UV exposure

 

Industrial Machine Tool Coolant & Cutting Fluid Compatibility (TM5 vs. Machine Oils)

 

Machine tool wireways are constantly contaminated by water-miscible cutting emulsions, synthetic coolants, and paraffinic hydraulic oils. Standard commercial PVC sheaths swell, soften, and short-circuit within months of coolant contact. OLFLEX 191 incorporates specialized plasticizer stabilization formulated to EN 50363-4-1 (TM5):

 

Coolant / Oil Exposure Type

Typical Machining Application

Standard PVC Sheath Vulnerability

OLFLEX 191 (TM5 Compound) Performance

Water-Soluble Cutting Emulsions

Milling, turning, grinding coolant flood nozzles

Water and surfactant molecules leach standard plasticizers; jacket shrinks and hardens

Oil resistance is stated to EN 50363-4-1 (TM5). Whether a specific cutting fluid is compatible depends on its chemistry - send the fluid data sheet and we will confirm with the factory

Synthetic & Semi-Synthetic Coolants

High-speed CNC machining centers

Aggressive biocides and corrosion inhibitors attack PVC polymer chains, creating surface cracks

Oil resistance is stated to EN 50363-4-1 (TM5). Whether a specific cutting fluid is compatible depends on its chemistry - send the fluid data sheet and we will confirm with the factory

Mineral-Based Waylube & Hydraulic Oils

Slideway lubrication and hydraulic power packs

Oil absorption causes severe swelling, softening, and loss of tensile strength

Oil resistance to EN 50363-4-1 (TM5).

Occasional Water-Oil Slurry Immersion

Chip conveyors and machine base sump trays

Trapped oily water causes insulation breakdown and jacket blister formation

Approved for interior wet locations including standing oil-water mixtures under medium mechanical loads.

 

North American Export Compliance & Dual-Rating Matrix (UL/CSA vs. IEC)

 

Exporting European-style automated machinery to North America frequently triggers site inspection rejection when machine internal cabling carries only CE/VDE markings. OLFLEX 191 resolves compliance friction by harmonizing North American AWM approvals with European metric construction:

 

Regulatory Dimension

North American Requirement (UL / CSA)

European Standard (IEC / VDE / EN)

Engineering Harmonization Benefit in OLFLEX 191

Safety Certification

UL AWM Style 21098 & cUL AWM I/II A/B

VDE 0295 / IEC 60228 Class 5 conductor, IEC 60332-1-2 flame test, EN 50363-4-1 TM5 oil resistance For AWM cable used in industrial machinery in the USA, NFPA 79 applies; the cable-side detail sits in appendix T29.

Voltage Rating

600 V AC rating for internal appliance wiring

300/500 V (U₀/U) nominal rating

Allows one cable to service both 400 V / 50 Hz European grids and 480 V / 60 Hz North American three-phase branch circuits.

Operating Temperature

90 °C dry temperature rating

70 °C continuous conductor limit

The 90 °C UL rating affords increased thermal ampacity margins inside high-density industrial control enclosures and junction boxes.

Flame Retardance Test

UL 1581 §1061 vertical cable flame test

IEC 60332-1-2 single-cable vertical burn test

Passes demanding North American vertical burn standards, preventing upward flame propagation along machine structural columns.

Conductor Sizing Rule

Recognized in AWG / kcmil equivalents

Manufactured to metric mm² cross-sections

Conductor cross-sections meet or exceed nearest AWG equivalents (e.g. 1.5 mm² exceeds 16 AWG; 2.5 mm² exceeds 14 AWG) as defined in catalogue appendix T16.

 

Under NFPA 79 (Electrical Standard for Industrial Machinery), AWM Style 21098 is officially recognized for internal machine wiring and factory-assembled machinery interconnects when applied within manufacturer temperature and voltage parameters.

 

Metric to AWG Reference Notice

 

OLFLEX 191 is manufactured to metric cross-sections with secondary AWG / kcmil equivalents recognized under UL/CSA AWM listings as detailed in catalogue appendix T16. Always state the Lapp part number on purchasing orders.

 

Metric Section (mm²)

Recognized North American AWG / kcmil Equivalent

0.75

18

1.0

17

1.5

16

2.5

14

4.0

12

6.0

10

10.0

8

16.0

6

25.0

4

35.0

2

50.0

1

70.0

2/0

95.0

3/0

120.0

4/0

 

OLFLEX 191

 

Oil-resistant multi-standard PVC control cable (UL AWM 21098 / CSA AWM / 600V). G = includes green-yellow protective earth core; X = without green-yellow core. Selected part numbers with integrated AWG equivalents.

 

Part No.

Cores × mm²

AWG / kcmil

Outer Diameter (mm)

Copper Index (kg/km)

Total Weight (kg/km)

0011112

2 X 0.5

20 AWG

5.2

11.5

40

0011100

3 G 0.5

20 AWG

6.2

16.4

62

0011101

4 G 0.5

20 AWG

6.9

22.0

68

0011102

5 G 0.5

20 AWG

7.4

28.0

87

0011103

7 G 0.5

20 AWG

9.1

39.0

119

0011105

12 G 0.5

20 AWG

11.3

66.0

198

0011106

18 G 0.5

20 AWG

12.1

86.4

267

0011107

25 G 0.5

20 AWG

15.6

137.0

380

0011223

9 G 0.75

18 AWG

10.5

64.8

152

0011113

3 G 1.0

17 AWG

6.7

28.8

66

0011115

5 G 1.0

17 AWG

8.1

48.0

95

Part No.

Cores × mm²

AWG / kcmil

Outer Diameter (mm)

Copper Index (kg/km)

Total Weight (kg/km)

0011116

7 G 1.0

17 AWG

8.9

67.2

125

0011118

18 G 1.0

17 AWG

14.4

172.8

309

0011120

34 G 1.0

17 AWG

22.4

296.0

742

0011137

3 G 1.5

16 AWG

7.3

44.0

91

0011143

18 G 1.5

16 AWG

16.1

260.0

444

0011150

3 G 2.5

14 AWG

8.4

72.0

138

0011151

4 G 2.5

14 AWG

9.1

96.0

182

0011152

5 G 2.5

14 AWG

10.2

120.0

216

0011165

4 G 6.0

10 AWG

13.0

231.0

358

0011172

4 G 16.0

6 AWG

22.1

615.0

904

0011176

5 G 25.0

4 AWG

28.0

1200.0

1640

 

Send Inquiry