OLFLEX CLASSIC 100 450/750V Power Cable

OLFLEX CLASSIC 100 450/750V Power Cable
Details:
OLFLEX CLASSIC 100 450/750V PVC power cable up to 185 mm2, plus the RAL 1016 yellow warning-sheath variant. Class 5 copper, 4 kV tested, IEC 60227-5. Cut to length.

Standards & Compliance
IEC 60227-5 | EN 50525-2-51 | VDE 0295 / IEC 60228 Class 5 | IEC 60332-1-2 | View standards

Quick Specs
450/750 V | 4000 V test | 2.5 – 185 mm² (grey) / 1.5 – 2.5 mm² (yellow) | −40 °C to +80 °C fixed
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex classic 100 450/750v power cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

OLFLEX CLASSIC 100 450/750V moves the family out of panel-level control work and into power distribution, motor supply and plant-level feeder runs that a 300/500 V grade cannot cover. The conductor range extends to 185 mm², so the same colour-coded PVC construction that dresses a machine tool also carries a sub-main. Two finishes are offered on this grade: the standard grey RAL 7001 sheath, and CLASSIC 100 YELLOW with a warning-yellow sheath to approximately RAL 1016 that marks circuits still energised after the main isolator has been opened. Conductors are Class 5 fine-wire bare copper to VDE 0295 / IEC 60228, and the design is qualified to IEC 60227-5 in addition to EN 50525-2-51. Fixed-installed with a protective earth core the cable is rated to 600/1000 V. The grey version spans 2.5 to 185 mm² in 2 to 8 cores; the yellow version covers 1.5 and 2.5 mm² in 3, 4 and 5 cores.

 

Selecting the Right 450/750 V Configuration

 

Grey or Yellow Jacket

Selection Factor

CLASSIC 100 450/750V (grey)

CLASSIC 100 YELLOW

Function

Power distribution and motor supply

Warning marking of live circuits

Sheath colour

PVC grey, RAL 7001

Warning yellow, approx. RAL 1016

Cross-section range

2.5 – 185 mm²

1.5 – 2.5 mm²

Core configurations

2 to 8 cores

3 G, 4 G, 5 G

600/1000 V with PE

Yes

Yes

 

 

The Yellow Variant - Marking Circuits That Stay Live

 

CLASSIC 100 YELLOW exists for one job: to make a circuit that is still live after the main switch has been opened impossible to overlook. The sheath colour is the marking, so no label, tag or marking tape has to survive the service life of the installation. It is specified for socket and lighting circuits fed from a distribution board that remain energised when the board's main isolator is off, and for the jumper section inside a wind turbine tower where the cable also has to tolerate torsion.

 

Parameter

CLASSIC 100 YELLOW

Sheath colour

Warning yellow, approximately RAL 1016

Rated voltage U₀/U

450/750 V

Available cross-sections

1.5 mm² and 2.5 mm²

Available core configurations

3 G, 4 G and 5 G (earth core fitted)

Design standards

IEC 60227-5 and EN 50525-2-51

Torsion rating

TW-0: ≥ +5 °C, ±150°/m, 5000 cycles · TW-1: ≥ −20 °C, ±150°/m, 2000 cycles

Flame retardancy

IEC 60332-1-2

 

Note that the yellow variant is a warning-sheath option, not a higher-performance cable. Its electrical construction follows the same 450/750 V platform as the grey version; what changes is the outer compound colour and the fact that it is released in a narrow cross-section band.

 

Typical Applications

 

01sub-main-and-feeder-cables-inside-industrial-distribution-boards-heavy-feeder-cores-entering-contactors-busbars-and-terminal-strips-in-a-control-cabinet

Sub-main and feeder cables inside industrial distribution boards.
Where a 300/500 V control grade is no longer appropriate and the run has to sit in the same duct system as the control wiring.

02motor-supply-from-a-starter-or-drive-to-the-machine-colour-coded-motor-cores-terminated-on-a-multi-way-strip-inside-a-cast-motor-terminal-box

Motor supply from a starter or drive to the machine.
Fixed installation between the panel and the motor terminal box, at conductor areas that reach well beyond the control range.

03wind-turbine-nacelle-jumper-sections-cable-bundles-running-along-the-nacelle-wall-past-control-cabinets-towards-the-tower-opening

Wind turbine nacelle jumper sections.
The TW-0 and TW-1 torsion ratings cover the jumper zone, so a separate torsion-rated cable does not have to be specified for that part of the tower.

04plant-level-power-and-lighting-circuits-in-a-distribution-switchboard-a-row-of-wall-mounted-panels-with-overhead-cable-trays-and-bottom-cable-entries

Plant-level power and lighting circuits in a distribution switchboard.
Where the yellow variant is used to identify outgoing ways that stay live when the main isolator is open, and the grey variant carries the rest.

 

Why Specify the 450/750 V Grade

 

A 450/750 V Grade That Also Carries 600/1000 V

 

Rated U₀/U 450/750 V. Fixed-installed with a green-yellow protective core present, the same article is rated 600/1000 V - one cable covers the control band and the sub-main, with no second product to specify.

01

Class 5 Copper To 185 mm², With A Short Lay

 

Conductors run from 2.5 mm² to 185 mm² to VDE 0295 / IEC 60228 Class 5, laid with a short pitch that raises flexibility. The fixed bend radius stays at 4 × OD right up to 185 mm², which is what keeps a sub-main routable inside a plant room.

02

Torsion-Rated For Wind Turbine Crossover Sections

 

TW-0 holds 5000 cycles at ± 150° per metre with a +5 °C floor; TW-1 holds 2000 cycles at the same ± 150° per metre down to −20 °C. That is the qualification behind the crossover section inside a wind turbine generator.

03

A Warning Sheath That Is A Colour, Not A Product

 

LASSIC 100 YELLOW is the same construction under a warning-yellow sheath to approximately RAL 1016, released in 1.5 and 2.5 mm² at 3, 4 and 5 cores. The colour is the marking - no label or tape has to survive the life of the installation.

04

 

Frequently Asked Questions

 

Q: What does the 600/1000 V rating mean on a 450/750 V cable?

A: The 450/750 V figure is the general rating. When the cable is fixed-installed and a green-yellow protective earth core is present, the permissible rating rises to 600/1000 V. Both figures describe the same product under different installation conditions.

Q: When is the yellow variant the right choice?

A: Whenever a circuit stays energised after the main isolator is opened and the installation needs that fact to be visible without relying on a label. Socket and lighting circuits fed from a distribution board are the standard case.

Q: Is the yellow version available above 2.5 mm²?

A: No. The yellow variant is released in 1.5 mm² and 2.5 mm² with 3, 4 or 5 cores. For larger conductor areas on a warning-marked circuit, the marking has to be carried by labelling or by a separate warning system.

Q: Can the 450/750 V grade be used in a drag chain?

A: No. Like the rest of the family it is rated for fixed installation and occasional flexing. Continuous drag-chain travel requires a dedicated drag-chain cable, since the failure mode there is conductor fatigue rather than voltage stress.

Q: Is the cable torsion-rated for a wind turbine nacelle?

A: Yes. The variants on this grade carry TW-0 (≥ +5 °C, ±150°/m, 5000 cycles) and TW-1 (≥ −20 °C, ±150°/m, 2000 cycles) ratings, which cover the jumper section inside the tower.

Q: How large a cross-section can be supplied and in what packaging?

A:Yes - cut lengths are available from factory stock. Minimum cut length and the cutting charge depend on the size; send the size and length and we will quote.

 

 

Hot Tags: olflex classic 100 450/750v power cable, China olflex classic 100 450/750v power cable suppliers

Electrical and Thermal Ratings

 

Parameter

Rating

Nominal voltage U₀/U

450/750 V

Factory dielectric test

4000 V

Temperature - fixed installation

−40 °C to +80 °C

Temperature - occasional flexing

−5 °C to +70 °C

Flame retardancy

IEC 60332-1-2, single-wire vertical flame test

Design standards

IEC 60227-5 and EN 50525-2-51

 

Construction and Core Identification

 

Layer / Property

Specification

Conductor

Class 5 fine-wire bare copper, VDE 0295 / IEC 60228 Class 5

Insulation

PVC, colour-coded

Identification - up to 5 cores

Solid core colours to VDE 0293-308

Identification - 6 cores and above

Colour code applied over the printed scheme

Protective conductor

G = green-yellow earth core included; X = no earth core

Outer sheath

PVC, grey RAL 7001, or warning yellow approx. RAL 1016

Torsion capability

TW-0 and TW-1 ratings for WTG crossover section jumper sections

 

Large-Cross-Section Handling - Pulling, Bending and Reel Logistics

 

Above roughly 70 mm² the cable stops behaving like a wire and starts behaving like a structural element: the drum weight, the stiffness and the bend radius all become planning inputs rather than details. The figures below are for the four-core construction across the range, at the sizes where handling practice changes.

 

Four-Core Size

Outer Diameter

Cable Weight

Fixed Radius (4 × OD)

4G2.5

10.7 mm

203 kg/km

≈ 43 mm

4G25

25.4 mm

1,582 kg/km

≈ 102 mm

4G70

39.4 mm

4,092 kg/km

≈ 158 mm

4G120

53.1 mm

6,994 kg/km

≈ 212 mm

4G150

57.4 mm

7,500 kg/km

≈ 230 mm

4G185

62.8 mm

8,300 kg/km

≈ 251 mm

 

Three practical consequences follow. First, plan the drum position before the route: at these masses the cable is paid off into the run rather than pulled through it, and every change of direction adds load that the conductor and the sheath both have to absorb. Second, support the cable on the tray rather than letting it hang between supports - the published bend radius assumes the cable is carrying its own weight over a short span, not sagging over a long one. Third, allow for a straight entry length into the terminal compartment; at 185 mm² the conductor will not be persuaded into a sharp landing, and forcing it puts the load straight onto the lug.

 

Reading the Part Number Tables

 

The AWG column gives nearest-area equivalents converted from the metric cross-section; these are not interchangeable with AWG-specified products. On this page the equivalent runs from 13 AWG at 2.5 mm² up through 1/0 at 50 mm², then switches to kcmil for the largest sizes — 300 kcmil at 150 mm² and 350 kcmil at 185 mm². Confirm any AWG requirement against the metric size before ordering. G indicates a green-yellow earth core is fitted; X indicates it is not.

 

CLASSIC 100 450/750V, Grey Jacket — Part Number Table

 

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

0010086

2×2.5

13

8.9

48.0

128

0010087

3G2.5

13

9.6

72.0

162

00100883

4G2.5

13

10.7

96.0

203

00100893

5G2.5

13

11.8

120.0

242

0010091

7G2.5

13

13.1

168.0

321

0010100

2×4

11

10.4

76.8

187

0010210

3G4

11

11.2

115.2

244

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

0010105

3G6

9

12.6

173.0

318

00101073

5G6

9

15.6

288.0

489

0010301

3G10

7

15.9

288.0

516

00101103

5G10

7

19.7

480.0

792

0010111

7G10

7

21.7

672.0

1,058

0010302

3G16

5

18.3

461.0

728

00101133

5G16

5

22.8

768.0

1,118

0010303

3G25

3

23.0

720.0

1,388

 

CLASSIC 100 YELLOW, Warning-Yellow Sheath — Part Number Table

 

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

0010400

3 G 1.5

15

8.1

43.0

95

00104023

4 G 1.5

15

8.9

58.0

117

00104033

5 G 1.5

15

10.0

72.0

144

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

0010401

3 G 2.5

13

9.6

72.0

152

00104043

4 G 2.5

13

10.7

96.0

205

00104053

5 G 2.5

13

11.8

120.0

225

 

Send Inquiry