Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of olflex classic 100 450/750v power cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Lead Paragraph
OLFLEX CLASSIC 100 450/750V moves the family out of panel-level control work and into power distribution, motor supply and plant-level feeder runs that a 300/500 V grade cannot cover. The conductor range extends to 185 mm², so the same colour-coded PVC construction that dresses a machine tool also carries a sub-main. Two finishes are offered on this grade: the standard grey RAL 7001 sheath, and CLASSIC 100 YELLOW with a warning-yellow sheath to approximately RAL 1016 that marks circuits still energised after the main isolator has been opened. Conductors are Class 5 fine-wire bare copper to VDE 0295 / IEC 60228, and the design is qualified to IEC 60227-5 in addition to EN 50525-2-51. Fixed-installed with a protective earth core the cable is rated to 600/1000 V. The grey version spans 2.5 to 185 mm² in 2 to 8 cores; the yellow version covers 1.5 and 2.5 mm² in 3, 4 and 5 cores.
Selecting the Right 450/750 V Configuration
Grey or Yellow Jacket
|
Selection Factor |
CLASSIC 100 450/750V (grey) |
CLASSIC 100 YELLOW |
|
Function |
Power distribution and motor supply |
Warning marking of live circuits |
|
Sheath colour |
PVC grey, RAL 7001 |
Warning yellow, approx. RAL 1016 |
|
Cross-section range |
2.5 – 185 mm² |
1.5 – 2.5 mm² |
|
Core configurations |
2 to 8 cores |
3 G, 4 G, 5 G |
|
600/1000 V with PE |
Yes |
Yes |
The Yellow Variant - Marking Circuits That Stay Live
CLASSIC 100 YELLOW exists for one job: to make a circuit that is still live after the main switch has been opened impossible to overlook. The sheath colour is the marking, so no label, tag or marking tape has to survive the service life of the installation. It is specified for socket and lighting circuits fed from a distribution board that remain energised when the board's main isolator is off, and for the jumper section inside a wind turbine tower where the cable also has to tolerate torsion.
|
Parameter |
CLASSIC 100 YELLOW |
|
Sheath colour |
Warning yellow, approximately RAL 1016 |
|
Rated voltage U₀/U |
450/750 V |
|
Available cross-sections |
1.5 mm² and 2.5 mm² |
|
Available core configurations |
3 G, 4 G and 5 G (earth core fitted) |
|
Design standards |
IEC 60227-5 and EN 50525-2-51 |
|
Torsion rating |
TW-0: ≥ +5 °C, ±150°/m, 5000 cycles · TW-1: ≥ −20 °C, ±150°/m, 2000 cycles |
|
Flame retardancy |
IEC 60332-1-2 |
Note that the yellow variant is a warning-sheath option, not a higher-performance cable. Its electrical construction follows the same 450/750 V platform as the grey version; what changes is the outer compound colour and the fact that it is released in a narrow cross-section band.
Typical Applications




Why Specify the 450/750 V Grade
A 450/750 V Grade That Also Carries 600/1000 V
Rated U₀/U 450/750 V. Fixed-installed with a green-yellow protective core present, the same article is rated 600/1000 V - one cable covers the control band and the sub-main, with no second product to specify.
01
Class 5 Copper To 185 mm², With A Short Lay
Conductors run from 2.5 mm² to 185 mm² to VDE 0295 / IEC 60228 Class 5, laid with a short pitch that raises flexibility. The fixed bend radius stays at 4 × OD right up to 185 mm², which is what keeps a sub-main routable inside a plant room.
02
Torsion-Rated For Wind Turbine Crossover Sections
TW-0 holds 5000 cycles at ± 150° per metre with a +5 °C floor; TW-1 holds 2000 cycles at the same ± 150° per metre down to −20 °C. That is the qualification behind the crossover section inside a wind turbine generator.
03
A Warning Sheath That Is A Colour, Not A Product
LASSIC 100 YELLOW is the same construction under a warning-yellow sheath to approximately RAL 1016, released in 1.5 and 2.5 mm² at 3, 4 and 5 cores. The colour is the marking - no label or tape has to survive the life of the installation.
04
Frequently Asked Questions
Q: What does the 600/1000 V rating mean on a 450/750 V cable?
A: The 450/750 V figure is the general rating. When the cable is fixed-installed and a green-yellow protective earth core is present, the permissible rating rises to 600/1000 V. Both figures describe the same product under different installation conditions.
Q: When is the yellow variant the right choice?
A: Whenever a circuit stays energised after the main isolator is opened and the installation needs that fact to be visible without relying on a label. Socket and lighting circuits fed from a distribution board are the standard case.
Q: Is the yellow version available above 2.5 mm²?
A: No. The yellow variant is released in 1.5 mm² and 2.5 mm² with 3, 4 or 5 cores. For larger conductor areas on a warning-marked circuit, the marking has to be carried by labelling or by a separate warning system.
Q: Can the 450/750 V grade be used in a drag chain?
A: No. Like the rest of the family it is rated for fixed installation and occasional flexing. Continuous drag-chain travel requires a dedicated drag-chain cable, since the failure mode there is conductor fatigue rather than voltage stress.
Q: Is the cable torsion-rated for a wind turbine nacelle?
A: Yes. The variants on this grade carry TW-0 (≥ +5 °C, ±150°/m, 5000 cycles) and TW-1 (≥ −20 °C, ±150°/m, 2000 cycles) ratings, which cover the jumper section inside the tower.
Q: How large a cross-section can be supplied and in what packaging?
A:Yes - cut lengths are available from factory stock. Minimum cut length and the cutting charge depend on the size; send the size and length and we will quote.
Hot Tags: olflex classic 100 450/750v power cable, China olflex classic 100 450/750v power cable suppliers
Electrical and Thermal Ratings
|
Parameter |
Rating |
|
Nominal voltage U₀/U |
450/750 V |
|
Factory dielectric test |
4000 V |
|
Temperature - fixed installation |
−40 °C to +80 °C |
|
Temperature - occasional flexing |
−5 °C to +70 °C |
|
Flame retardancy |
IEC 60332-1-2, single-wire vertical flame test |
|
Design standards |
IEC 60227-5 and EN 50525-2-51 |
Construction and Core Identification
|
Layer / Property |
Specification |
|
Conductor |
Class 5 fine-wire bare copper, VDE 0295 / IEC 60228 Class 5 |
|
Insulation |
PVC, colour-coded |
|
Identification - up to 5 cores |
Solid core colours to VDE 0293-308 |
|
Identification - 6 cores and above |
Colour code applied over the printed scheme |
|
Protective conductor |
G = green-yellow earth core included; X = no earth core |
|
Outer sheath |
PVC, grey RAL 7001, or warning yellow approx. RAL 1016 |
|
Torsion capability |
TW-0 and TW-1 ratings for WTG crossover section jumper sections |
Large-Cross-Section Handling - Pulling, Bending and Reel Logistics
Above roughly 70 mm² the cable stops behaving like a wire and starts behaving like a structural element: the drum weight, the stiffness and the bend radius all become planning inputs rather than details. The figures below are for the four-core construction across the range, at the sizes where handling practice changes.
|
Four-Core Size |
Outer Diameter |
Cable Weight |
Fixed Radius (4 × OD) |
|
4G2.5 |
10.7 mm |
203 kg/km |
≈ 43 mm |
|
4G25 |
25.4 mm |
1,582 kg/km |
≈ 102 mm |
|
4G70 |
39.4 mm |
4,092 kg/km |
≈ 158 mm |
|
4G120 |
53.1 mm |
6,994 kg/km |
≈ 212 mm |
|
4G150 |
57.4 mm |
7,500 kg/km |
≈ 230 mm |
|
4G185 |
62.8 mm |
8,300 kg/km |
≈ 251 mm |
Three practical consequences follow. First, plan the drum position before the route: at these masses the cable is paid off into the run rather than pulled through it, and every change of direction adds load that the conductor and the sheath both have to absorb. Second, support the cable on the tray rather than letting it hang between supports - the published bend radius assumes the cable is carrying its own weight over a short span, not sagging over a long one. Third, allow for a straight entry length into the terminal compartment; at 185 mm² the conductor will not be persuaded into a sharp landing, and forcing it puts the load straight onto the lug.
Reading the Part Number Tables
The AWG column gives nearest-area equivalents converted from the metric cross-section; these are not interchangeable with AWG-specified products. On this page the equivalent runs from 13 AWG at 2.5 mm² up through 1/0 at 50 mm², then switches to kcmil for the largest sizes — 300 kcmil at 150 mm² and 350 kcmil at 185 mm². Confirm any AWG requirement against the metric size before ordering. G indicates a green-yellow earth core is fitted; X indicates it is not.
CLASSIC 100 450/750V, Grey Jacket — Part Number Table
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
0010086 |
2×2.5 |
13 |
8.9 |
48.0 |
128 |
|
0010087 |
3G2.5 |
13 |
9.6 |
72.0 |
162 |
|
00100883 |
4G2.5 |
13 |
10.7 |
96.0 |
203 |
|
00100893 |
5G2.5 |
13 |
11.8 |
120.0 |
242 |
|
0010091 |
7G2.5 |
13 |
13.1 |
168.0 |
321 |
|
0010100 |
2×4 |
11 |
10.4 |
76.8 |
187 |
|
0010210 |
3G4 |
11 |
11.2 |
115.2 |
244 |
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
0010105 |
3G6 |
9 |
12.6 |
173.0 |
318 |
|
00101073 |
5G6 |
9 |
15.6 |
288.0 |
489 |
|
0010301 |
3G10 |
7 |
15.9 |
288.0 |
516 |
|
00101103 |
5G10 |
7 |
19.7 |
480.0 |
792 |
|
0010111 |
7G10 |
7 |
21.7 |
672.0 |
1,058 |
|
0010302 |
3G16 |
5 |
18.3 |
461.0 |
728 |
|
00101133 |
5G16 |
5 |
22.8 |
768.0 |
1,118 |
|
0010303 |
3G25 |
3 |
23.0 |
720.0 |
1,388 |
CLASSIC 100 YELLOW, Warning-Yellow Sheath — Part Number Table
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
0010400 |
3 G 1.5 |
15 |
8.1 |
43.0 |
95 |
|
00104023 |
4 G 1.5 |
15 |
8.9 |
58.0 |
117 |
|
00104033 |
5 G 1.5 |
15 |
10.0 |
72.0 |
144 |
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
0010401 |
3 G 2.5 |
13 |
9.6 |
72.0 |
152 |
|
00104043 |
4 G 2.5 |
13 |
10.7 |
96.0 |
205 |
|
00104053 |
5 G 2.5 |
13 |
11.8 |
120.0 |
225 |