60227 IEC 52 (RVV) CCC Control Cable

60227 IEC 52 (RVV) CCC Control Cable
Details:
60227 IEC 52 (RVV) 300/300 V CCC-certified PVC control cable. Class 5 copper, colour-coded cores, IEC 60332-1-2 flame test. Three voltage grades on one page — cut to length or terminated assembly.

Standards & Compliance
IEC 60227-5 | GB/T 5023.5 | CCC | IEC 60228 Class 5 | VDE 0293-308 | IEC 60332-1-2 | JB/T 8734.3 (106 RVV)

Quick Specs
300/300 V (CCC) | 2000 V test | 0.5 – 0.75 mm² (2 – 3 cores) | −25 °C to +70 °C fixed | CCC-certified PVC
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 60227 iec 52 (rvv) ccc control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

60227 IEC 52 (RVV) is the 300/300 V economy cord: Class 5 stranded bare copper to GB/T 3956 / IEC 60228, black PVC sheath, colour-coded cores to VDE 0293-308 for up to five conductors. Six article numbers cover the 2- and 3-core sizes at 0.5 and 0.75 mm² that account for most panel interior and equipment wiring. Test voltage is 2000 V, the temperature window runs to −25 °C fixed and −5 °C with occasional movement, and the bend radius holds at 4 × OD for fixed runs. Where the circuit needs more - a higher voltage class, extra cores or a section above 0.75 mm² - two OLFLEX 106 RVV ranges close those gaps, all sharing the same PVC construction and available cut, terminated and tested before shipment.

 

Select Your Variant

 

By Application

Requirement

Choose

Why

Fixed panel or equipment wiring, light load, installed once

60227 IEC 52 (RVV) 300/300 V - this series

300/300 V covers the circuit; 2–3 cores at 0.5–0.75 mm² land on panel terminals; cord construction keeps unit cost down

Higher voltage rating needed (300/500 V)

OLFLEX106 60227 IEC 53(RVV) 300/500 V

2500 V test, same PVC build, 2–5 cores from 0.75 to 2.5 mm²

Six cores or more, or a 0.75 mm² bundle with one 2.0 mm² core

OLFLEX106 RVV 300/500 V

6 to 41 cores up to 10 mm², including mixed-section composite rows to JB/T 8734.3

Continuous bending or drag-chain travel

None of the three

All three are fixed-installation / occasional-bending cords; continuous duty needs a dedicated drag-chain cable

 

 

Typical Applications

 

01control-panel-with-hmi-touchscreen-cable-glands-and-terminal-wiring-inside-a-production-cell

Fixed wiring inside equipment and panels
Fixed wiring is where 4 × OD earns its keep: it turns inside a crowded wireway without a service loop, at cord-level cost.

02corrugated-board-production-line-with-heated-rollers-forming-a-continuous-sheet-in-a-plant-hall

Wiring inside industrial machinery
Class 5 fine-wire copper forms around a terminal instead of springing back, and the tape wrap keeps the black sheath round on the run.

03stainless-steel-filling-machine-with-hopper-process-tanks-and-conveyor-surrounded-by-guard-rails

Occasional bending - machine door or guard
Rated for occasional movement at 10 × OD, so a door or guard is served by the same article as the static run beside it.

04circular-saw-station-cutting-aluminium-tube-to-length-on-a-roller-conveyor-behind-safety-guards

Cut to length or terminated assembly
Cut lengths and finished assemblies come from the same article numbers, so the prototype and the production harness share one specification.

 

Why Choose this Cable

 

The Core Counts Panels Actually Ask For

 

One construction runs from 2 cores at 0.5 mm² to 41 cores at 10 mm², so a panel builder stocks one family instead of three.

01

Colour Codes That Remove a Continuity Test

 

Cores are read by colour up to five and by white numbers from six up, so termination comes off the cable instead of off a meter.

02

A Thermal Window That Is Published, Not Implied

Two ratings on one cable - −25 °C fixed and −5 °C occasional - so one article covers the static panel run and the door that opens for service.

03

Three Voltage Classes on One Page

 

CCC-certified 300/300 V at 2000 V, and 300/500 V at 2500 V for the step above, in the same PVC build.

04

 

Frequently Asked Questions

 

Q: Which of the three versions on this page do I need?

A: Start from the circuit. If the run is fixed, carries a light load and lands on a panel terminal, the 300/300 V cord is the most economical fit. Move to the 300/500 V cord when the circuit rating or core count requires it. Step up to the multi-core RVV when the core count passes five, the section exceeds 2.5 mm², or the drawing shows 0.75 mm² cores alongside a 2.0 mm² core.

Q: What does the 300/300 V rating mean in practice?

A: U₀/U of 300/300 V means 300 V to earth and 300 V between conductors - the class IEC 60227-5 assigns to light PVC cords for equipment and panel circuits. The two 300/500 V versions on this page use the same PVC construction but carry a 2500 V test voltage for installations that see a higher system voltage.

Q: What cores and sections does this cable come in?

A: This series is catalogued in 2 and 3 cores at 0.5 and 0.75 mm² - six article numbers. Three-core rows are catalogued both with and without a green-yellow earth core. Outside that range, the two 106 versions listed below cover 2–5 cores at 0.75–2.5 mm² and 6–41 cores at 0.5–10 mm².

Q: Is the cable CCC certified?

This series is CCC certified. The 300/500 V multi-core range is built to JB/T 8734.3. Tell us the supply route - KABASI stock, a brand you name, or material you supply - and we will confirm which certificate applies before the order is placed. 

Q: Can the cable be bent repeatedly?

A: In the sense the catalogue gives it: occasional, non-continuous movement with no tensile load on the cable, at 10 × OD and within −5 °C to +70 °C. That suits a door, a guard or an adjustable fitting opened for service. A run that is flexed continuously, pulled by a moving part or carried in a drag chain is outside the rating.

 

 

Hot Tags: 60227 iec 52 (rvv) ccc control cable, China 60227 iec 52 (rvv) ccc control cable suppliers

60227 IEC 52 (RVV) 300/300 V - Full Parameters

 

Parameter

Value

Nominal Voltage

300/300 V (U₀/U)

Test Voltage

2000 V

Conductor

Class 5 stranded bare copper (GB/T 3956 / IEC 60228 Class 5)

Insulation

PVC

Outer Sheath

PVC, black

Core Identification

Colour code to VDE 0293-308, up to five cores

Protective Conductor

G row: green-yellow earth core in the lay-up; X row: none

Temperature - Fixed

−25 °C to +70 °C

Temperature - Occasional Flexing

−5 °C to +70 °C

Min. Bending Radius - Fixed

4 × OD

Min. Bending Radius - Occasional

10 × OD

Flame Retardancy

IEC 60332-1-2

Design Standard

IEC 60227-5 / GB/T 5023.5

Certification

CCC 

 

Comparison - The Three Series 

 

Parameter

300/300 V (this series)

OLFLEX 106 IEC 53 RVV 300/500 V

OLFLEX 106 RVV 300/500 V

Standard

IEC 60227-5 / GB/T 5023.5

IEC 60227-5 / GB/T 5023.5

JB/T 8734.3

Rated voltage

300/300 V

300/500 V

300/500 V

Test voltage

2000 V

2500 V

2500 V

Cross-section range

0.5 – 0.75 mm²

0.75 – 2.5 mm²

0.5 – 10 mm²

Core counts

2 – 3

2 – 5

6 – 41 (+ composite)

Core ID

VDE 0293-308 colour, ≤5 cores

Colours for 2–5; ≥6: black + numbers + G/Y

Same as 106 IEC 53 RVV

Temp. - fixed / occasional

−25 / −5 °C to +70 °C

−25 / −5 °C to +70 °C

−25 / −5 °C to +70 °C

 

60227 IEC 52 (RVV) 300/300 V

 

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

834710002

2×0.5

20

5.5

9.6

31

834690003

3G0.5

20

5.8

14.4

45

834710003

3×0.5

20

5.8

14.4

45

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

834710102

2×0.75

18

5.9

14.4

40

834690103

3G0.75

18

5.9

21.6

50

834710103

3×0.75

18

6.3

21.6

50

 

ÖLFLEX 106 60227 IEC 53(RVV) 300/500 V

 

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

834700102

2×0.75

18

6.5

14.4

40

834700103

3G0.75

18

6.8

21.6

45

834700104

4G0.75

18

7.4

28.8

59

834700105

5G0.75

18

8.3

36.0

73

834700202

2×1

17

6.8

19.2

45

834700203

3G1

17

7.2

28.8

55

834700204

4G1

17

8.1

38.4

69

834700205

5G1

17

8.8

48.0

85

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

834700302

2×1.5

15

7.6

28.8

58

834700303

3G1.5

15

8.3

43.2

71

834700304

4G1.5

15

9.2

57.6

88

834700305

5G1.5

15

10.3

72.0

115

834700402

2×2.5

13

9.7

48.0

85

834700403

3G2.5

13

10.5

72.0

115

834700404

4G2.5

13

11.5

96.0

140

834700405

5G2.5

13

12.8

120.0

178

 

ÖLFLEX 106 RVV 300/500 V

 

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

834700010

10G0.5

20

9.5

48.0

103

834700012

12G0.5

20

10.6

57.6

117

834700019

19G0.5

20

13.3

91.2

255

834700020

20G0.5

20

13.5

96.0

265

834700106

6G0.75

18

7.0

43.2

86

Part No.

Cores × mm²

AWG

OD (mm)

Cu (kg/km)

Weight (kg/km)

834700107

7G0.75

18

7.8

50.4

95

834700237

37G0.75

18

16.3

266.4

460

834700704

4G10

7

20.0

384.0

780

834707503

2×0.75+1×2

18/14

7.0

28.8

55

834707539

38×0.75+1×2

18/14

18.5

292.8

498

 