Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 60227 iec 52 (rvv) ccc control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Lead Paragraph
60227 IEC 52 (RVV) is the 300/300 V economy cord: Class 5 stranded bare copper to GB/T 3956 / IEC 60228, black PVC sheath, colour-coded cores to VDE 0293-308 for up to five conductors. Six article numbers cover the 2- and 3-core sizes at 0.5 and 0.75 mm² that account for most panel interior and equipment wiring. Test voltage is 2000 V, the temperature window runs to −25 °C fixed and −5 °C with occasional movement, and the bend radius holds at 4 × OD for fixed runs. Where the circuit needs more - a higher voltage class, extra cores or a section above 0.75 mm² - two OLFLEX 106 RVV ranges close those gaps, all sharing the same PVC construction and available cut, terminated and tested before shipment.
Select Your Variant
By Application
|
Requirement |
Choose |
Why |
|
Fixed panel or equipment wiring, light load, installed once |
60227 IEC 52 (RVV) 300/300 V - this series |
300/300 V covers the circuit; 2–3 cores at 0.5–0.75 mm² land on panel terminals; cord construction keeps unit cost down |
|
Higher voltage rating needed (300/500 V) |
OLFLEX106 60227 IEC 53(RVV) 300/500 V |
2500 V test, same PVC build, 2–5 cores from 0.75 to 2.5 mm² |
|
Six cores or more, or a 0.75 mm² bundle with one 2.0 mm² core |
OLFLEX106 RVV 300/500 V |
6 to 41 cores up to 10 mm², including mixed-section composite rows to JB/T 8734.3 |
|
Continuous bending or drag-chain travel |
None of the three |
All three are fixed-installation / occasional-bending cords; continuous duty needs a dedicated drag-chain cable |
Typical Applications




Why Choose this Cable
The Core Counts Panels Actually Ask For
One construction runs from 2 cores at 0.5 mm² to 41 cores at 10 mm², so a panel builder stocks one family instead of three.
01
Colour Codes That Remove a Continuity Test
Cores are read by colour up to five and by white numbers from six up, so termination comes off the cable instead of off a meter.
02
A Thermal Window That Is Published, Not Implied
Two ratings on one cable - −25 °C fixed and −5 °C occasional - so one article covers the static panel run and the door that opens for service.
03
Three Voltage Classes on One Page
CCC-certified 300/300 V at 2000 V, and 300/500 V at 2500 V for the step above, in the same PVC build.
04
Frequently Asked Questions
Q: Which of the three versions on this page do I need?
A: Start from the circuit. If the run is fixed, carries a light load and lands on a panel terminal, the 300/300 V cord is the most economical fit. Move to the 300/500 V cord when the circuit rating or core count requires it. Step up to the multi-core RVV when the core count passes five, the section exceeds 2.5 mm², or the drawing shows 0.75 mm² cores alongside a 2.0 mm² core.
Q: What does the 300/300 V rating mean in practice?
A: U₀/U of 300/300 V means 300 V to earth and 300 V between conductors - the class IEC 60227-5 assigns to light PVC cords for equipment and panel circuits. The two 300/500 V versions on this page use the same PVC construction but carry a 2500 V test voltage for installations that see a higher system voltage.
Q: What cores and sections does this cable come in?
A: This series is catalogued in 2 and 3 cores at 0.5 and 0.75 mm² - six article numbers. Three-core rows are catalogued both with and without a green-yellow earth core. Outside that range, the two 106 versions listed below cover 2–5 cores at 0.75–2.5 mm² and 6–41 cores at 0.5–10 mm².
Q: Is the cable CCC certified?
This series is CCC certified. The 300/500 V multi-core range is built to JB/T 8734.3. Tell us the supply route - KABASI stock, a brand you name, or material you supply - and we will confirm which certificate applies before the order is placed.
Q: Can the cable be bent repeatedly?
A: In the sense the catalogue gives it: occasional, non-continuous movement with no tensile load on the cable, at 10 × OD and within −5 °C to +70 °C. That suits a door, a guard or an adjustable fitting opened for service. A run that is flexed continuously, pulled by a moving part or carried in a drag chain is outside the rating.
Hot Tags: 60227 iec 52 (rvv) ccc control cable, China 60227 iec 52 (rvv) ccc control cable suppliers
60227 IEC 52 (RVV) 300/300 V - Full Parameters
|
Parameter |
Value |
|
Nominal Voltage |
300/300 V (U₀/U) |
|
Test Voltage |
2000 V |
|
Conductor |
Class 5 stranded bare copper (GB/T 3956 / IEC 60228 Class 5) |
|
Insulation |
PVC |
|
Outer Sheath |
PVC, black |
|
Core Identification |
Colour code to VDE 0293-308, up to five cores |
|
Protective Conductor |
G row: green-yellow earth core in the lay-up; X row: none |
|
Temperature - Fixed |
−25 °C to +70 °C |
|
Temperature - Occasional Flexing |
−5 °C to +70 °C |
|
Min. Bending Radius - Fixed |
4 × OD |
|
Min. Bending Radius - Occasional |
10 × OD |
|
Flame Retardancy |
IEC 60332-1-2 |
|
Design Standard |
IEC 60227-5 / GB/T 5023.5 |
|
Certification |
CCC |
Comparison - The Three Series
|
Parameter |
300/300 V (this series) |
OLFLEX 106 IEC 53 RVV 300/500 V |
OLFLEX 106 RVV 300/500 V |
|
Standard |
IEC 60227-5 / GB/T 5023.5 |
IEC 60227-5 / GB/T 5023.5 |
JB/T 8734.3 |
|
Rated voltage |
300/300 V |
300/500 V |
300/500 V |
|
Test voltage |
2000 V |
2500 V |
2500 V |
|
Cross-section range |
0.5 – 0.75 mm² |
0.75 – 2.5 mm² |
0.5 – 10 mm² |
|
Core counts |
2 – 3 |
2 – 5 |
6 – 41 (+ composite) |
|
Core ID |
VDE 0293-308 colour, ≤5 cores |
Colours for 2–5; ≥6: black + numbers + G/Y |
Same as 106 IEC 53 RVV |
|
Temp. - fixed / occasional |
−25 / −5 °C to +70 °C |
−25 / −5 °C to +70 °C |
−25 / −5 °C to +70 °C |
60227 IEC 52 (RVV) 300/300 V
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
834710002 |
2×0.5 |
20 |
5.5 |
9.6 |
31 |
|
834690003 |
3G0.5 |
20 |
5.8 |
14.4 |
45 |
|
834710003 |
3×0.5 |
20 |
5.8 |
14.4 |
45 |
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
834710102 |
2×0.75 |
18 |
5.9 |
14.4 |
40 |
|
834690103 |
3G0.75 |
18 |
5.9 |
21.6 |
50 |
|
834710103 |
3×0.75 |
18 |
6.3 |
21.6 |
50 |
ÖLFLEX 106 60227 IEC 53(RVV) 300/500 V
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
834700102 |
2×0.75 |
18 |
6.5 |
14.4 |
40 |
|
834700103 |
3G0.75 |
18 |
6.8 |
21.6 |
45 |
|
834700104 |
4G0.75 |
18 |
7.4 |
28.8 |
59 |
|
834700105 |
5G0.75 |
18 |
8.3 |
36.0 |
73 |
|
834700202 |
2×1 |
17 |
6.8 |
19.2 |
45 |
|
834700203 |
3G1 |
17 |
7.2 |
28.8 |
55 |
|
834700204 |
4G1 |
17 |
8.1 |
38.4 |
69 |
|
834700205 |
5G1 |
17 |
8.8 |
48.0 |
85 |
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
834700302 |
2×1.5 |
15 |
7.6 |
28.8 |
58 |
|
834700303 |
3G1.5 |
15 |
8.3 |
43.2 |
71 |
|
834700304 |
4G1.5 |
15 |
9.2 |
57.6 |
88 |
|
834700305 |
5G1.5 |
15 |
10.3 |
72.0 |
115 |
|
834700402 |
2×2.5 |
13 |
9.7 |
48.0 |
85 |
|
834700403 |
3G2.5 |
13 |
10.5 |
72.0 |
115 |
|
834700404 |
4G2.5 |
13 |
11.5 |
96.0 |
140 |
|
834700405 |
5G2.5 |
13 |
12.8 |
120.0 |
178 |
ÖLFLEX 106 RVV 300/500 V
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
834700010 |
10G0.5 |
20 |
9.5 |
48.0 |
103 |
|
834700012 |
12G0.5 |
20 |
10.6 |
57.6 |
117 |
|
834700019 |
19G0.5 |
20 |
13.3 |
91.2 |
255 |
|
834700020 |
20G0.5 |
20 |
13.5 |
96.0 |
265 |
|
834700106 |
6G0.75 |
18 |
7.0 |
43.2 |
86 |
|
Part No. |
Cores × mm² |
AWG |
OD (mm) |
Cu (kg/km) |
Weight (kg/km) |
|
834700107 |
7G0.75 |
18 |
7.8 |
50.4 |
95 |
|
834700237 |
37G0.75 |
18 |
16.3 |
266.4 |
460 |
|
834700704 |
4G10 |
7 |
20.0 |
384.0 |
780 |
|
834707503 |
2×0.75+1×2 |
18/14 |
7.0 |
28.8 |
55 |
|
834707539 |
38×0.75+1×2 |
18/14 |
18.5 |
292.8 |
498 |