UL1015 — 600 V Single-Core Wire

UL1015 — 600 V Single-Core Wire
Details:
UL1015 is the 600 V single core, and the reason an assembly can be specified from one item instead of two: the same conductor family runs from a signal tap up to the largest supply conductor in the range.
Standards & Compliance
UL758, UL1581 | CSA C22.2 No.210.2 | UL VW-1, CSA FT1, JQA-F-Mark | RoHS, REACH
Quick Specs
600 V | 80 / 90 / 105 °C | 30 AWG to 2000 kcmil | PVC, single core, unsheathed | 2000 VAC through 3 AWG, rising to 2500 VAC from 2 AWG
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of ul1015 — 600 v single-core wire in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

UL1015 is the 600 V member of the single-core range, and the only one whose schedule reaches a 2000 kcmil conductor. Two things follow from that rating. The first is voltage: 600 V covers internal circuits that the 300 V Styles cannot, without changing insulation compound or moving to a jacketed cable. The second is reach: the same Style is specified for a 30 AWG signal tap and for a heavy internal supply conductor, which removes a second item from the bill of materials. The core is a tinned or bare copper conductor inside PVC, rated 80, 90 and 105 °C, supplied unsheathed, and built to UL758 and UL1581 construction with the UL VW-1, CSA FT1 and JQA-F-Mark flame tests.

 

Why 600 V Changes the Conductor Schedule

A 600 V single core does not simply repeat the 300 V schedule at a higher figure. UL1015 runs in two parts: the fine sizes close at 8 AWG, and a second table opens at 7 AWG and runs through 1, 2/0, 3/0 and 4/0 to a 2000 kcmil single conductor. That split exists because the heavy end is not an oversized control conductor - it is a supply conductor, and it is dimensioned against current rather than against the terminal it lands on.

 

The dielectric figure changes inside the heavy table. Through 3 AWG the stated value is 2000 VAC for one minute; from 2 AWG upward, including 4/0, it is 2500 VAC. The wall is a separate property and steps three times - 0.76 mm over 30 to 9 AWG, 1.14 mm at 8 and 7 AWG, 1.52 mm from 6 to 2 AWG and 2.03 mm from 1 AWG up - so the test figure and the wall are stated independently against the same schedule.

 

Where UL1015 Is Specified: 600 V Buses, Heavy Feeds, Warm Cabinets

 

 

Where the internal circuit is 600 V, or where one conductor has to be both a signal tap and a heavy supply, UL1015 is the single core ordered. A control wire at 30 AWG and a 4/0 supply conductor come off the same schedule, so the assembly is specified from one Style and the warm-cabinet ratings cost nothing at the higher voltage.

ul1015-single-core-wire-industrial-control-panel-wiring

Why Specify UL1015

A Dielectric Step Where the Conductor Gets Heavy

The 2000 to 2500 VAC step at 2 AWG is the detail that separates a 600 V Style from a scaled-up 300 V one: the heavy end is a schedule of its own, not one continuous table. When a design mixes 8 AWG control wiring with 2/0 supply conductors in the same panel, both come from this schedule and both carry a stated figure.

 

One Style From a Signal Tap to 2000 kcmil

The range of the schedule is the practical argument. Most single-core Styles stop somewhere between 14 and 16 AWG at the heavy end, which forces a second item onto the order as soon as the internal supply is heavier than the control wiring. UL1015 runs from 30 AWG to 2000 kcmil, so the whole internal run is specified from one Style, one resistance table and one set of test figures.

 

Three Temperature Ratings on One PVC Core

The core is rated 80, 90 and 105 °C rather than at a single temperature. The three entries are not three products: they are the window the same PVC construction is rated for, which lets the 600 V item be used in a cabinet that runs at 105 °C without switching to XLPE or to a jacketed cable.

Frequently Asked Questions

 

Q: What is UL1015 wire rated for?

A: 600 V at 80, 90 and 105 °C, in a PVC insulated single core with a tinned or bare copper conductor from 30 AWG to a 2000 kcmil conductor. It is the widest conductor schedule in the single-core internal wiring range.

Q: UL1015 or UL1007? 

A: By voltage and by the top of the schedule. UL1007 is the 300 V member and closes at 16 AWG; UL1015 is the 600 V member and reaches 2000 kcmil. Both are unsheathed PVC single cores, so where the circuit is a 300 V circuit the lighter Style is the better fit and where it is not, UL1015 is the item.

Q: Why does the dielectric strength change at 2 AWG?

A: It is stated per size rather than derived from one figure: 2000 VAC for one minute through 3 AWG, 2500 VAC from 2 AWG upward including 4/0. The wall also steps, to 1.52 mm from 6 to 2 AWG and 2.03 mm from 1 AWG up. Both are test values; the working rating stays at 600 V across the whole schedule.

Q: Does 2000 kcmil mean two thousand strands?

A: No. kcmil is a cross-sectional area in thousands of circular mils, not a strand count. A 2000 kcmil conductor is a very large single conductor, and the stranding inside it is fixed on the order.

Q: Is UL1015 shielded or jacketed?

A: Neither. It is an unsheathed single core with PVC insulation over the conductor. Where a screen or an outer jacket is required, the jacketed single cores in the same range carry them.

Q: Can UL1015 run at 105 °C?

A: Yes. 80, 90 and 105 °C all apply to this Style, at the full 600 V rating. The temperature entries apply across the schedule rather than to selected sizes.

Q: Can UL1015 be supplied cut to length and terminated?

A: Yes. The core is cut to length, and terminated assemblies are built to the drawing with the termination specified - a ferrule, a ring terminal or a connector shell. Wire and assembly are quoted together.

 

Hot Tags: ul1015 — 600 v single-core wire, China ul1015 — 600 v single-core wire suppliers

UL1015 at a Glance

 

UL Style Rated voltage Rated temperature Conductor range Insulation Dielectric strength (VAC, 1 min)
UL1015 600 V 80 / 90 / 105 °C 30 AWG - 2000 kcmil PVC 2000 through 3 AWG; 2500 from 2 AWG

 

Schedule and Test Data

 

Item UL1015
Conductor Tinned or bare copper, 30 AWG to 2000 kcmil
Schedule, fine end 30 AWG to 8 AWG
Schedule, heavy end 7 AWG through 1, 2/0, 3/0 and 4/0 to 2000 kcmil
Insulation PVC
Dielectric strength 2000 VAC through 3 AWG; 2500 VAC from 2 AWG upward
Flame test UL VW-1, CSA FT1, JQA-F-Mark
Reference standards UL758, UL1581, CSA C22.2 No.210.2
Send Inquiry