Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of super-paar-tronic 340-c-pur data cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Positioning of the Paired Data Cable Range
SUPER-PAAR-TRONIC 340-C-PUR is a paired, screened continuous-flex data cable for noise-critical links in advanced machinery: rotary-encoder feedback, optical-scale position sensing and precision sensor networks. Where high-power VFDs and servo motors dominate, concentric-layer cables pick up electromagnetic pulse induction and suffer common-mode interference, cross-pair crosstalk and CNC communication timeouts. A back-twist precision pair construction cancels induced noise symmetrically across the pair. Conductors are bare copper, extra-fine stranded, to DIN VDE 0295 class 6, BS 6360 class 6 and IEC 60228 class 6for flex-fatigue life. Polypropylene insulation holds mutual capacitance to about 60 nF/km, preserving steep pulse edges over distance. An 85 % tinned copper braid and a halogen-free TMPU jacket carry the UL/CSA dual approval.
Pair Symmetry, Capacitance and Impedance Budget
When integrating sensitive high-frequency feedback circuits inside dynamic machinery drag chains, signal distortion and encoder pulse loss predominantly stem from cable crosstalk and impedance mismatch. Based on HELUKABEL industrial measurement guidelines, installation must adhere to four essential rules:
Differential Transmission & Back-Twist Pairing Noise Cancellation
Each pair in 340-C-PUR is precision twisted with short, staggered lay pitches. Close geometrical twisting ensures external electromagnetic radiation induces equal, opposite electromotive forces in the two conductors, which cancel completely at differential inputs. The pairs are laid at an optimum pitch with back-twist and stranded in layers, which is the construction that keeps a pair symmetrical from one end of the run to the other.
01
PP Dielectric Constant & 60 nF/km Low-Capacitance Control
PP insulation is what holds mutual capacitance to about 60 nF/km, and that figure is the one that decides how steep a pulse edge survives a long track run. In RS422, RS485, and incremental encoder line-driver circuits, this minimizes AC capacitive loading and significantly extends unrepeatered transmission distances.
02
DIN 47100 Color-Code Pinout Discipline
Core identification follows DIN 47100, so the pairs land in the order a European drawing expects.When wiring D-Sub plugs, M12 industrial circular connectors, or terminal strips, differential signal pairs must strictly occupy conductors from the same twisted pair. Splitting twisted pairs destroys differential noise cancellation.
03
High-Frequency Impedance Continuity & 360-Degree Grounding
At cabinet entry points, the tinned copper braid screen must achieve uninterrupted 360-degree circumferential contact with metal bulkheads via EMC cable glands or metallic grounding saddles. Never twist the shield into a pigtail lead, which introduces inductive impedance and destroys high-frequency noise suppression. Keep the stripped length as short as the terminal allows; the braid is only continuous up to the point where the shield is opened.
04
Why Specify SUPER-PAAR-TRONIC 340-C-PUR
Why robotics and CNC automation development engineers specify SUPER-PAAR-TRONIC 340-C-PUR for dynamic signal paths:
|
Transmission property |
Commissioning benefit |
|
Precision back-twist paired architecture eliminates drive-induced crosstalk |
Twisted differential pairs provide self-canceling noise immunity, preventing encoder data packet drops and optical scale position jitter. |
|
Low 60 nF/km mutual capacitance preserves high-speed square-wave pulse integrity |
Minimal dielectric loss ensures steep signal transition edges, supporting high baud rates over extended cable track runs. |
|
PU jacket carry the UL/CSA dual approval. Halogen-free TMPU polyurethane jacket, 85 % braid coverage |
Multiplies service life compared to standard PVC, with extreme resistance to mechanical flex fatigue, tear damage, and surface waviness. |
|
Full compliance with classic DIN 47100 paired color code speeds cabinet assembly |
Distinct paired color coding enables fast terminal landing without inspecting microscopic numerical print, eliminating miswiring risks. |
| Resistant to oils to DIN EN 60811-404, and to solvents, acids, alkalis and hydraulic fluids |
Full polyurethane jacket maintains structural strength and elasticity under continuous oil spray, preventing swelling or softening. |
|
Dual UL/CSA certifications streamline worldwide export compliance |
Meets strict North American flammability and electrical standards, allowing global machine builders to standardize on a single cable worldwide. |
Typical Applications
Four primary high-dynamic precision automation deployment sectors for SUPER-PAAR-TRONIC 340-C-PUR:




Frequently Asked Questions
Q: How does SUPER-PAAR-TRONIC 340-C-PUR differ from drag chain control cables like JZ-HF?
A: Their engineering roles are strictly segregated: JZ-HF is a concentric-layer power/control cable (black cores with white numerals) for motor feeds and solenoids. 340-C-PUR is a paired differential data cable featuring twisted pairs, DIN 47100 color coding, and low-capacitance PP insulation specifically designed for weak encoder and bus communications.
Q: Why does this cable utilize specialized PP insulation instead of conventional PVC?
A: PP rather than PVC insulation is the reason mutual capacitance sits at about 60 nF/km - the property that keeps a pulse edge readable at the end of a long carrier run. to ensure clean, undistorted pulse transmission.
Q: What does the designation "Pairs x 2 x Cross-Section" signify (e.g., 4 x 2 x 0.25)?
A: It denotes that the cable contains 4 separate twisted pairs, each formed by twisting two 0.25 mm2 extra-fine conductors together, totaling 8 conductors. Each pair carries one balanced differential circuit (such as RS485 A/B or encoder A+/A- channels).
Q: Can data cables be bundled together with high-power motor cables inside a drag chain?
A: Direct bundling is strictly prohibited. Despite high-density screening, switching transients from adjacent motor cables generate extreme near-field magnetic pulses. Run data cables in their own compartment of the carrier, with a divider between them and the motor cables.
Q: What dynamic bending radii are specified for 340-C-PUR?
A: Owing to paired structural elasticity: gauges <= 0.25 mm2 require a tight dynamic bend radius of only 7.5x OD in continuous flex motion. Gauges from 0.5 to 1.0 mm2 are specified at 10x OD (fixed installation requires 4-5x OD), fitting compact machinery guide channels.
Q: What core advantages does the TMPU polyurethane jacket provide over PVC?
A: TMPU full polyurethane offers superior abrasion, tear, and cut-through resistance, preventing hydrolysis breakdown in aggressive machine coolants.It keeps its cold impact strength (−30 °C moving, −40 °C fixed), which is the property that matters at a machine that starts cold.
Ordering 340-C-PUR and Harness Entry
Cable quote entry - 340-C-PUR samples, paired impedance and attenuation data
Harness entry - submit an encoder or vision-link harness drawing for a screening and grounding review
Hot Tags: super-paar-tronic 340-c-pur data cable, China super-paar-tronic 340-c-pur data cable suppliers
Transmission & Environmental Baseline
|
Operating voltage |
Conductor |
Temperature (fixed) |
Test voltage |
Pair configuration |
|
300 V (Drag Chain) |
Class 6 extra-fine copper |
−40 °C to +80 °C |
1500 V / 1000 V |
0.14 – 1.0 mm² (1–14 pairs) |
Transmission Standards and Approvals
Conductor DIN VDE 0295 cl. 6 col. 4 / IEC 60228 | Color code DIN 47100 | Halogen-free TMPU jacket DIN EN 50363-10-2 | UL 1581 tab.50.227 (AWM) | Flame retardance IEC 60332-1 | Low Voltage Directive 2014/35/EU
Filtering by Pair Count and Gauge
Part-number filtering — read the size designation as Pairs x 2 x Cross-Section, then filter by pair count (1–14) and the six gauges from 0.14 to 1.0 mm².
340-C-PUR Part-Number Schedule