JZ-HF high-flex drag-chain control cable series featuring DIN VDE 0295 class 6 extra-fine bare copper conductors (class 5 on JZ-HF-FCY), oil-resistant PVC jacket, and non-woven fleece wrapping. Includes unshielded JZ-HF, EMC-screened JZ-HF-CY, and UL/CSA certified JZ-HF-FCY. 9-million cycle endurance.

Standards & Compliance
DIN EN 50525-2-51 / DIN VDE 0285-525-2-51 | DIN VDE 0295 cl. 6 | IEC 60332-1-2 | UL/CSA AWM 2570 (JZ-HF-FCY only)

Quick Specs
300/500 V (FCY: UL 1000 V) | 0.5-16 mm², 2-65 cores | 7.5 × OD / 4 × | −10 to +80 °C moving | 4000 V AC test
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of helukabel jz-hf drag chain cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Positioning of the Drag-Chain Range

 

JZ-HF is built for dynamic cable-track and drag-chain systems in CNC machining centres, robotic lines, material-handling systems and warehouse shuttle carriers,it uses bare copper extra-fine strands to DIN VDE 0295 class 6, stranded at an optimum pitch in layers, which is the construction that survives repeated reversal. and uses high-purity annealed bare copper extra-fine strands to DIN VDE 0295 class 6 / IEC 60228 class 6 for extreme flex-fatigue resistance. PVC Z7225 insulation is cabled at short, tension-free lay lengths and wrapped in a low-friction non-woven fleece separator that removes internal shear friction, heat build-up and corkscrew binding. The oil-resistant PVC TM5 jacket handles cutting fluids and lubricating emulsions. The family spans unshielded JZ-HF, EMC-screened JZ-HF-CY and UL/CSA AWM Style 2570 JZ-HF-FCY.

 

Screened or Unscreened JZ-HF Selection

 

The JZ-HF family organizes dynamic continuous-flexing control requirements into three standardized models:

Three core drag chain variants comparative matrix

Variant

Screening structure

Dynamic bend radius

Rated voltage

Recommended machine condition

JZ-HF (Unshielded)

Unshielded, lightweight slim profile

Dynamic 7.5 x OD

300 / 500 V

Medium-to-long travel drag chains, compact carrier channels, environments without severe electromagnetic noise

JZ-HF-CY (EMC Shielded)

PVC inner jacket + 85% tinned copper braid

Dynamic 10.0 x OD

300 / 500 V

Carrier tracks adjacent to inverter motor feeds and servo drives where pulse noise suppression is critical

JZ-HF-FCY (UL/CSA Certified)

Separating foil + 85% tinned copper braid

Dynamic 10.0 x OD

1000 V (UL AWM 2570)

Heavy industrial machine tools and automated logistics equipment destined for export to North American markets

 

Quick convergence by machine motion & electrical environment

Match machinery motion profiles and regulatory destinations directly to the correct model specification:

Operating / motion condition

Recommended variant

Engineering check item

CNC machining center spindles (high motor noise radiation)

JZ-HF-CY Shielded

85% tinned copper braid suppresses radiated pulse harmonics

Multi-axis robot arm articulation (tight bending clearances)

JZ-HF Unshielded

Slim 5.0-14.0 mm OD with tight 7.5x OD bend radius reduces dynamic drag mass on articulated joints

Export equipment bound for the United States or Canada

JZ-HF-FCY Certified

UL AWM Style 2570 and CSA dual certification at 1000V eliminates on-site field recertification hurdles

High-speed automated logistics sorting and shuttle lines

All Class 6 Conductors

Extra-fine class 6 stranding, laid at an optimum pitch in layers

 

Duty-Cycle Envelope and Carrier Routing Rules

 

Most drag-chain failures trace back to the carrier rather than the cable. Based on HELUKABEL engineering guidelines, JZ-HF continuous-flex applications must observe four mandatory principles:

 

Duty-Cycle Envelope Parameters

Travel length, speed and acceleration are set by the carrier maker's own limits for the track, not by the cable. Where the duty goes beyond a standard PVC carrier - long unsupported spans, high speed, or permanent contact with coolant - the PUR range is the next step.

01

Zero-Tension and Free-Floating Carrier Installation

Fit each cable with a divider or frame stay, leaving free movement space of at least 10 % of the cable diameter; cables of very different diameters must not run side by side.

 

02

Dual-End Strain Relief Clamping Rules

Strain relief clamps at both carrier entry and exit points must grip the robust outer jacket firmly without compressing internal conductor insulation. Maintain a straight transition buffer zone of at least 20-30 times the cable outer diameter between the clamp and the active carrier hinge bend; never clamp directly adjacent to the dynamic bending radius.

03

EMC 360-Degree Circumferential Grounding Practice

For shielded models JZ-HF-CY and JZ-HF-FCY, the copper braid at both ends must achieve continuous 360-degree circumferential contact with metal bulkhead plates using EMC cable glands or metallic grounding saddles. Never twist the braid into a pigtail lead, which introduces inductive impedance and destroys high-frequency noise suppression.

04

 

Typical Applications

 

01high-speed-cnc-machine-tool-three-axis-guide-carriers-cable-in-the-carrier-at-a-7-5-x-od-bend-reversing-on-every-stroke

High-speed CNC machine tool three-axis guide carriers
Machine-tool wiring at 7.5 x OD, where the carrier runs the length of the bed and reverses on every stroke.

02industrial-multi-axis-robotic-arms-and-linear-7th-axis-tracks-six-axis-arm-cables-bent-at-10-x-od-on-the-screened-run

Industrial multi-axis robotic arms and linear 7th-axis tracks
Six-axis arms and their seventh-axis tracks, bent at 10 x OD once the run is screened.

03automated-high-density-warehouse-shuttle-vehicles-class-6-copper-strand-cable-on-conveyors-and-shuttles-built-for-reversals

Automated high-density warehouse shuttle vehicles
Warehouse conveyors and shuttles, on a class 6 copper strand built for reversals rather than for a fixed route.

04global-export-heavy-industrial-machinery-and-packaging-lines-ul-csa-build-with-1000-v-approval-bending-at-10-x-od

Global export heavy industrial machinery and packaging lines
Export machines, where the UL/CSA build carries its own 1000 V approval and still bends at 10 x OD.

 

Why Specify JZ-HF

 

Why automation system builders standardize on JZ-HF for dynamic carrier track engineering:

JZ-HF design point

Carrier-track effect

DIN VDE 0295 class 6 extra-fine stranding

Micro-fine stranding provides extreme fatigue resilience against cyclic reversal, eliminating unscheduled production stops from wire breaks.

Low-friction synthetic fleece wrapping eliminates internal friction heat

Cushions core movement within the outer jacket, allowing conductors to glide smoothly and preventing corkscrew binding and exterior jacket waviness.

Compact 7.5x OD dynamic bend radius saves valuable carrier interior space

Requires 30% less clearance than standard 10-15x OD cables, enabling machine builders to specify smaller, lighter drag-chain carriers.

85% coverage tinned copper braid provides EMC immunity without work hardening

Optimized braid geometry preserves high electromagnetic shielding in harsh inverter electrical environments without strand breakage.

Special PVC TM5 jacket resists aggressive machine cutting coolants

Withstands continuous washdown from industrial cutting emulsions and hydraulic fluids without jacket swelling, softening, or cracking.

UL/CSA 1000V certification streamlines machine exports to North America

JZ-HF-FCY features UL AWM Style 2570 approval at 1000V, eliminating engineering redesigns when exporting machinery worldwide.

 

Frequently Asked Questions

 

Q: What is the fundamental engineering difference between JZ-HF and standard JZ-500?

A: The mechanical lifespan differs by orders of magnitude: JZ-500 uses class 5 conductors without internal friction separators, designed only for fixed or occasional non-continuous flexing (7.5x OD mobile / 4x OD fixed bend radius). JZ-HF is engineered specifically for drag chains with class 6 extra-fine copper strands and a low-friction synthetic fleece wrapping, requiring only 7.5 x OD dynamic bend radius.

Q: Why do unshielded JZ-HF and shielded JZ-HF-CY require different bend radii?

A: JZ-HF-CY incorporates a PVC inner jacket and an 85% coverage tinned copper wire braid. Metal screening adds mechanical resistance during flexing. To prevent braid fatigue and work-hardening wire breakage, the dynamic bend radius for shielded models is specified at 10x OD, compared to 7.5x OD for unshielded JZ-HF.

Q: What specific advantages does the JZ-HF-FCY model offer?

A: JZ-HF-FCY is a dual-certified model engineered for global machinery exports: it carries UL AWM Style 2570 and CSA approvals with a high operating voltage rating of 1000 V (versus 300/500V on European models). Incorporating individual core separating foils and meeting UL 1581 flame retardance, it is the standard choice for machinery exported to the USA and Canada.

Q: When should a machine builder upgrade from PVC to PUR drag chain cables?

A: Upgrade to polyurethane-sheathed PURö-JZ-HF when travel distance exceeds 10 meters, travel speeds surpass 2 m/s, or operating environments involve aggressive prolonged immersion in cutting oils and sharp flying metal swarf. For standard indoor machinery travels up to 10 meters under moderate mechanical stress, the special PVC TM5 compound of JZ-HF delivers exceptional cost efficiency.

Q: How can I prevent drag chain cables from developing corkscrew deformation?

A: Corkscrew binding is almost always caused by torsional twisting introduced during unreeling. Always unroll cables tangentially off rotating spools rather than looping them over the flange. Within the drag chain, use dividers to maintain 10% clearance around the cable, avoid bundling, and ensure adequate straight strain-relief transition zones at both ends.

Q: How do I identify whether a part number includes a green-yellow earth core?

A: HELUKABEL utilizes standard European notation: "G" signifies that the outer layer includes a green-yellow protective earth core (e.g., 3 G 0.75 designates 3 cores, one being green-yellow); "x" designates OZ all-black cores with white numerals without an earth wire. Simply reference the respective G or x column in the part-number schedule.

 

Ordering JZ-HF and Harness Entry

 

Cable quote entry - JZ-HF samples and the complete series part-number schedule

Harness entry - submit a carrier-track engineering questionnaire for a routing and strain-relief review

 

 

Hot Tags: helukabel jz-hf drag chain cable, China helukabel jz-hf drag chain cable suppliers

Drag-Chain Baseline Ratings

 

Rated voltage

Conductor

Temperature, moving / fixed

Test voltage

Cross-section and core range

300/500 V (FCY: UL 1000 V)

Class 6 extra-fine copper (FCY class 5)

−10 °C to +80 °C moving / −40 °C to +80 °C fixed

4000 V AC

0.5 – 16 mm² (2–65 cores)

 

Drag-Chain Electrical & Fatigue Performance

 

Electrical & mechanical baseline parameters

Parameter

Standard specification

Regulatory & harmonized standards

Compliant with DIN VDE 0285-525-2-51 and DIN EN 50525-2-51; FCY type compliant with UL 758 / CSA C22.2

Conductor manufacturing

High-purity bare copper extra-fine strands to DIN VDE 0295 class 6, BS 6360 class 6, and IEC 60228 class 6

Core insulation compound

High-elastic special PVC compound Z7225 delivering superior low-temperature recovery and dielectric strength

Core cabling & strain relief

Short-pitch concentric cabling with low-friction non-woven synthetic fleece wrapping to relieve internal shear stress

Outer jacket compound

Special modified oil-resistant PVC TM5 (grey RAL 7001) to DIN EN 50363-4-1 and UL 1581

Flame retardancy rating

Self-extinguishing and flame retardant compliant with IEC 60332-1 and DIN EN 60332-1-2 vertical flame tests

Chemical & coolant resistance

Rigorously tested to DIN EN 60811-404 and DIN VDE 0473-811-404 for mineral oil and industrial coolant immersion

Environmental compliance

Free from cadmium, silicone, and paint-wetting impairment substances; fully CE 2014/35/EU compliant

 

Drag chain dynamic fatigue comparative performance

Engineering dimension

Comparative characteristics

Flex fatigue resistance (vs. stationary wire)

Stationary cables like JZ-500 utilize class 5 conductors and fail under continuous dynamic bending; JZ-HF uses class 6 extra-fine wire rated for 9 million cycles

Internal shear friction mitigation

Matte insulation surfaces paired with low-friction non-woven fleece prevent core adhesion and thermal friction degradation during continuous 180-degree flexing

EMC screening angle & dynamic endurance

Screen braid angles on CY and FCY are optimized specifically for carrier flexure, preventing strand shearing and braid loosening over dynamic lifespans

Cold thermal impact toughness

Engineered oil-resistant PVC compound retains high dynamic elasticity down to -10 C in drag chains and down to -40 C in stationary applications

 

Standards and UL/CSA Registration

 

Conductor DIN VDE 0295 class 6 / IEC 60228 class 6 (JZ-HF-FCY class 5) | Control cable DIN EN 50525-2-51 / DIN VDE 0285-525-2-51 | Flame retardance IEC 60332-1 / DIN EN 60332-1-2 | UL/CSA AWM Style 2570 (FCY type) | Low Voltage Directive 2014/35/EU

 

Filtering Variant, Core Count and Size

 

Part-number filtering — filter by core count (2–65) and 0.5–16 mm², then switch between the three variant columns: unshielded JZ-HF, screened JZ-HF-CY and UL/CSA JZ-HF-FCY.

 

JZ-HF Part-Number Schedule by Variant

 

Complete part-number schedule for JZ-HF high-flex drag-chain control cable series (JZ-HF, JZ-HF-CY, JZ-HF-FCY) across canonical cross-sections, strictly including AWG wire gauges and millimeter cross-sections:
JZ-HF

01 JZ-HF complete part-number schedule article numbers by core count and cross-section two-column layout001


JZ-HF-CY

02 JZ-HF-CY complete part-number schedule screened article numbers by core count and cross-section two-column layout001


JZ-HF-FCY

03 JZ-HF-FCY complete part-number schedule UL-CSA article numbers by core count and cross-section two-column layout

 

Send Inquiry