The moderate-flex drag chain cable is one construction offered at three screen steps: TRVV unshielded, TRVVP with a tinned copper braided overall screen, and TRVVSP with the pair twisted inside that screen. All three share an ultra-fine bare copper stranded conductor, special elastomer insulation and a special NBR (nitrile rubber) compound jacket.
Standards & Compliance
UL758, TÜV and enterprise standards | UL E531888-UL-758 (optional) | CCC 5023 & 8734 (optional) | GB/T 18380, VW-1 (optional)
Quick Specs
300/300 V (≤0.5 mm²) | 300/500 V (>0.5 mm²) | 5 × OD fixed / 8 × OD moving | −10 °C to +70 °C | Bending life >7 million cycles | Three screen steps: none / braid / twisted pair + braid
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of trvv moderate-flex drag chain cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

The moderate-flex drag chain cable is split into three series by the way it is screened, over one shared construction: an ultra-fine bare copper stranded conductor, special elastomer insulation and a special NBR (nitrile rubber) compound jacket, built for installation in successive reciprocating motion and especially for frequent bending in industrial environments. The three differ only in the screen - TRVV carries none, TRVVP adds a tinned copper braided overall screen outside the insulation, and TRVVSP twists the pair inside that screen. Travel acceleration is 20 m/s² and bending life exceeds 7 million cycles at 60 cycles/min/m; rated voltage comes in two steps by cross-section, 300/300 V at 0.5 mm² and below and 300/500 V above; the minimum bending radius is 5 × OD fixed and 8 × OD moving, on a working temperature of −10 °C to +70 °C fixed and −5 °C to +70 °C moving. Every one of those figures is identical across the three series; only the core identification step differs.

 

Select Your Series

 

In short: all three series share one conductor / insulation / jacket construction, with the same rated voltage, bending radius, temperature range and bending life - they differ in the screen, and in TRVVSP in the core identification step, which widens to 10 cores.

 

 By On-Site Interference Conditions

  • TRVV: no screen, so the jacket encloses three layers only - conductor, insulation and jacket - for locations with no strong interference source.
  • TRVVP: a tinned copper braided overall screen, for locations that need screening.

  • TRVVSP: the pair twisted plus a tinned copper braided overall screen, the twisting sitting inside the overall screen.

 

Requirement Recommended Series Basis
No strong interference source, power or ordinary control circuits TRVV Conductor, insulation, jacket, rated voltage, bending radius, temperature range and bending life are identical across the three series, so this duty needs no extra screen
Locations that need screening TRVVP or TRVVSP Both screened series are specified for indoor and outdoor locations that need screening
VFDs, servo motors and high-power power lines running in parallel TRVVP The tinned copper braided overall screen gives good resistance to electromagnetic interference
Encoder, bus and analogue signal circuits TRVVSP The twisting inside the overall screen couples the pairs less than a single overall screen does

 

 

Typical Applications

The application range is a set of duties rather than a list of industries. The four below are those duties.

 

drag-chain-cable-running-in-the-carrier-of-a-cnc-machine-tool-1536x1536

Installation in successive reciprocating motion
Especially in frequent bending situations in industrial environments, which is the duty the series is built for.

drag-cable-in-the-carrier-of-an-automation-cell-1536x1536

Drag chain systems in modern mechanical standard components
The drag chain is the most typical installation, with logistics and control systems alongside it.

drag-chain-cable-routed-along-a-carrier-at-a-heavy-machinery-plant-1536x1536

Machine automation systems
Internal wiring and moving sections in CNC machine tools, electronic equipment, hardware stamping and injection moulding machines.

drag-chain-cable-in-the-carrier-section-of-an-automated-warehouse-1536x1536

Locations that need screening
Both screened series are specified for indoor and outdoor locations that need screening.

 

Why Choose the Moderate-Flex Drag Chain Cable

01

Three screen steps, one set of mechanical and electrical figures.

Conductor, insulation, jacket, rated voltage, bending radius, temperature range and bending life are identical across TRVV, TRVVP and TRVVSP, so choosing a series means choosing a screen.

 
02

Tinned copper braided overall screen: good resistance to electromagnetic interference.

Parallel VFDs, servo motors and high-power power lines all generate strong fields; the tinned copper braid closes over all of them, and both TRVVP and TRVVSP carry it.

 
03

Twisted pair inside the overall screen: still lower coupling between the pairs.

TRVVSP twists the pair inside the overall screen, coupling the pairs less than a single overall screen does - a layer a single screen cannot give on encoder, bus or analogue runs.

 
04

Bending life above 7 million cycles at 20 m/s² travel acceleration.

Bending life exceeds 7 million cycles at 60 cycles/min/m; the minimum bending radius is 5 × OD fixed and 8 × OD moving, on a working temperature of −10 °C to +70 °C fixed and −5 °C to +70 °C moving.

 

 

Frequently Asked Questions

Q: How do the three series differ?

A: In the screen, and in the core identification step. TRVV carries no screen; TRVVP adds a tinned copper braided overall screen; TRVVSP twists the pair inside that overall screen. On identification, TRVV and TRVVP use insulation colour up to 5 cores and white numbers above 5, while TRVVSP widens that to 10 cores by insulation colour and white numbers above 10. Rated voltage, bending radius, temperature range, travel characteristics and bending life are identical across the three.

Q: Is the rated voltage the same on all three?

A: Yes. 300/300 V at 0.5 mm² and below, 300/500 V above 0.5 mm².

Q: Are the bending radius and the temperature range the same?

A: Yes. The minimum bending radius is 5 × OD fixed and 8 × OD moving; the temperature range is −10 °C to +70 °C fixed and −5 °C to +70 °C moving.

Q: What is the bending life?

A: Above 7 million cycles at 60 cycles/min/m, on a travel acceleration of 20 m/s², identical across the three series.

Q: What form does the screen take?

A: TRVVP and TRVVSP both carry a tinned copper braided overall screen, and TRVVSP adds twisting inside that layer. TRVV carries no screen.

Q: What are the conductor, insulation and jacket materials?

A: Identical across the three: ultra-fine bare copper stranded conductor, special elastomer insulation and a special NBR (nitrile rubber) compound jacket. Core and jacket colours and materials can be made to customer requirement.

Q: How are the cores identified?

A: TRVV and TRVVP use insulation colour up to 5 cores and white numbers above 5; TRVVSP uses insulation colour up to 10 cores and white numbers above 10. Both can be made to a specified requirement.

Q: Which standards and approvals apply?

A: The reference standards are UL758, TÜV and enterprise standards. The cable is available to UL E531888-UL-758 and CCC 5023&8734, and flame retardancy passes GB/T 18380 and meets VW-1 - all three optional.

Q: What are the chemical and service properties?

A: Identical across the three: good resistance to oil, cold and acid and alkali solvents; the service properties are waterproofing, oil resistance, UV resistance and cold resistance, with a certain mechanical stress taken.

 

Harness Assembly and Finished Supply

 

All three series leave the factory either as bare cable on a reel or as a finished harness: the harness carries the same item as the cable, cut and terminated to the drawing, and it is quoted together with the cable rather than as a second transaction. For a new harness, give the length of each run, the drag chain travel and the termination at each end.

 

Hot Tags: trvv moderate-flex drag chain cable, China trvv moderate-flex drag chain cable suppliers

Specifications Common to the Three Series

 

Parameter

Rating

Rated voltage U0/U by cross-section

≤0.5 mm²: 300/300 V; >0.5 mm²: 300/500 V

Conductor

Ultra-fine bare copper, finely stranded

Insulation

Special elastomer compound

Outer sheath

Special NBR (nitrile rubber) compound

Minimum bending radius

5 × OD fixed; 8 × OD moving

Temperature range

Fixed −10 °C to +70 °C; moving −5 °C to +70 °C

Drag-chain duty

20 m/s² travel acceleration; bending life >7 million cycles at 60 cycles/min/m

Core identification

≤5 cores by insulation colour, >5 by white numbers (TRVVSP: ≤10 / >10)

Flame retardancy

To GB/T 18380; VW-1 (optional)

Features

Soft and durable sheath; UV and weathering resistance; oil and cold resistance; takes a certain mechanical stress

Reference standards

UL758, TÜV, enterprise standards (all three series)

Certification

UL E531888-UL-758; CCC 5023&8734 (optional)

 

Item-by-Item Comparison Across the Three Series

A row split by series gives the value for each of the three; a row merged across the columns is the same on all three. Reference standards and certification numbers are listed per series - take the column for the series you are specifying.

 

Parameter

TRVV

TRVVP

TRVVSP

Series

Unshielded drag chain cable

Shielded drag chain cable

Pair-twisted shielded drag chain cable

Screen

None

Tinned copper braid

Twisted pair + tinned copper braid

Conductor / insulation / outer sheath

Ultra-fine bare copper / special elastomer / special NBR compound

Rated voltage U0/U

≤0.5 mm²: 300/300 V; >0.5 mm²: 300/500 V

Minimum bending radius

5D fixed; 8D moving

Temperature range

Fixed −10 to +70 °C; moving −5 to +70 °C

Bending cycles and operation

20 m/s²; >7 million cycles at 60 cycles/min/m

Core identification

≤5 colour / >5 white numbers

≤5 colour / >5 white numbers

≤10 colour / >10 white numbers

Application

Indoor and outdoor

Indoor and outdoor, screened locations

Indoor and outdoor, screened locations

Flame retardancy

GB/T 18380; VW-1 (optional)

Reference standards

UL758, TÜV, enterprise standards

Certification

UL E531888-UL-758; CCC 5023&8734 (optional)

 