UL1007 — 300 V Single-Core Hook-Up Wire

UL1007 — 300 V Single-Core Hook-Up Wire
Details:
UL1007 is the single core that most internal wiring starts from: one conductor in a 0.38 mm PVC wall, small enough to enter a standard terminal solid or stranded to suit the way it is dressed.
Standards & Compliance
UL758, UL1581 | CSA C22.2 No.210.2 | UL VW-1, CSA FT1, JQA-F-Mark | RoHS, REACH
Quick Specs
300 V | 80 °C | 32 - 16 AWG | PVC, single core, unsheathed | 2000 VAC (1 min) dielectric
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of ul1007 — 300 v single-core hook-up wire in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

UL1007 is the baseline of the single-core range and the Style most internal wiring is specified against. Three numbers define it: 300 V, 80 °C, and a conductor schedule that closes at 16 AWG. That narrowness is the point. The wire is the right answer when the circuit inside the enclosure is an ordinary control, signal or internal supply circuit, when the ambient stays inside the PVC window, and when the conductor does not need to be heavier than 16 AWG. Step outside any of the three and a neighbour takes over: a conductor heavier than 16 AWG moves to UL1061, which reaches 14 AWG on a thinner wall, or to UL1569, which reaches 10 AWG at 80, 90 and 105 °C; an interior running at 105 °C moves to UL10368 on XLPE. The build itself is simple - a tinned or bare copper conductor, solid or stranded, inside a 0.38 mm nominal PVC wall, supplied unsheathed and cut to length.

 

What the 300 V and 80 °C Pair Covers

 

The rating is a pair, and both halves carry weight at the specification stage. 300 V is the working voltage the Style is rated at; dielectric strength is a different figure, 2000 VAC held for one minute. Keeping the two apart prevents the common error of reading a test result as a working rating - a core that withstands 2000 VAC for a minute is a 300 V core, and a 300 V circuit asks for nothing beyond that.

 

Typical Application

 

 

Inside a housed appliance the conductor runs from the terminal block to the switch, the board and the load, and it is bent by hand on the way. UL1007 is the 300 V core ordered for that run: one 0.38 mm PVC wall over tinned or bare copper, 32 to 16 AWG, narrow enough to land on the terminal the housing already has, and available solid or stranded to suit how it is dressed.

ul-single-core-wire-landed-on-terminal-blocks-inside-electrical-enclosure-600x300

Why Specify UL1007

A Wall That Fits the Terminal, Not Only the Circuit

The nominal insulation thickness is 0.38 mm, and with it the finished diameter runs from 1.00 mm at 32 AWG to 2.36 mm at 16 AWG. That is the figure a terminal block, a ferrule or a crimp barrel is actually chosen against: the wall has to be thick enough to hold 2000 VAC for a minute, and thin enough that the core still enters the rated range of the terminal without forcing a larger frame.

 

Resistance Given Gauge by Gauge

Maximum conductor resistance is listed per gauge at 20 °C DC rather than summarised into one headline number, because most sizes are offered in more than one stranding. At 32 AWG the listed window runs 563 to 595 Ω/km, at 24 AWG 87.6 to 94.2, and at 16 AWG 13.7 to 14.0. A voltage-drop calculation can therefore be done against the construction actually ordered, without asking for a separate data sheet.

 

A Schedule That Stops Where It Should

UL1007 ends at 16 AWG on purpose. Heavier conductors continue in UL1061 up to 14 AWG and in UL1569 up to 10 AWG, both at the same 300 V, and the 105 °C duty continues in UL10368. Keeping the default Style bounded keeps the resistance table short and the common sizes in stock, while the heavy end and the hot end are specified deliberately rather than by accident.

 

Frequently Asked Questions

 

Q: What is UL1007 wire used for?

A: UL1007 is general purpose internal wiring of appliances: the control, signal and internal supply conductors inside an enclosure, terminated on terminals and terminal blocks. Rated 300 V and 80 °C, in conductor sizes from 32 AWG to 16 AWG.

Q: UL1007 or UL1015?

A: The rated voltage separates them. UL1007 is the 300 V member and closes at 16 AWG; UL1015 is the 600 V member and runs up to 2000 kcmil. Both are PVC-insulated single cores without a jacket. Where the internal circuit is a 300 V circuit, UL1007 is the lighter of the two and the one that fits a smaller terminal.

Q: UL1007 or UL1061?

A: By wall thickness and by the top of the schedule. UL1007 carries a 0.38 mm nominal wall over 32 to 16 AWG; UL1061 carries a 0.23 to 0.32 mm wall over 30 to 14 AWG. Both are 300 V and 80 °C, so the choice comes down to whether the design needs the thinner wall or the 14 AWG end.

Q: Is the 300 V figure a test voltage?

A: No. 300 V is the rated working voltage. The test figure is 2000 VAC applied for one minute, and it is stated separately for every size in the schedule.

Q: What finished diameter should be allowed for?

A: From 1.00 mm at 32 AWG to 2.36 mm at 16 AWG, on the 0.38 mm nominal wall. The exact figure for a given order depends on the stranding chosen within that gauge.

Q: Which stranding is available?

A: Solid and stranded constructions are both offered for most sizes, which is why resistance appears as a window per gauge rather than as a single value. The stranding is fixed on the order and confirmed on the quotation.

Q: Can UL1007 be supplied cut to length or as a harness?

A: Both. The wire is cut to length, and where terminated assemblies are preferred the same conductor is assembled to the drawing with the termination called for - a ferrule, a ring terminal, a connector shell or the housing on the customer drawing. Wire and assembly are quoted in one document.

 

Hot Tags: ul1007 — 300 v single-core hook-up wire, China ul1007 — 300 v single-core hook-up wire suppliers

UL1007 at a Glance

 

Layer UL1007
Conductor Tinned or bare copper, 32 AWG to 16 AWG
Insulation PVC, 0.38 mm nominal thickness
Core Single conductor, unsheathed
Finished diameter 1.00 mm at 32 AWG to 2.36 mm at 16 AWG
Dielectric strength 2000 VAC for one minute
Flame Passes UL VW-1, CSA FT1 and JQA-F-Mark
Insulation colour To the customer requirement
Reference standards UL758, UL1581, CSA C22.2 No.210.2

Conductor and Insulation Data

 

Item UL1007
Conductor Tinned or bare copper, 32 AWG to 16 AWG
Nominal insulation thickness 0.38 mm
Finished diameter 1.00 mm at 32 AWG to 2.36 mm at 16 AWG
Maximum conductor resistance 563 - 595 Ω/km at 32 AWG; 13.7 - 14.0 Ω/km at 16 AWG (20 °C DC)
Dielectric strength 2000 VAC for one minute
Flame test UL VW-1, CSA FT1, JQA-F-Mark
Reference standards UL758, UL1581, CSA C22.2 No.210.2

 

Send Inquiry