Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of tronic liyy and tronic-cy flexible data cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
A Data Cable Sized to the Connector, Not to the Load
TRONIC is a data cable, sized by the connector rather than by current. A two-core 0.14 mm² build measures 3.5 mm across the sheath; with foil and braid the same two cores come in at 3.9 mm, and the single-core screened version is 2.6 mm, small enough for miniature plug bodies. Sizes run from 0.14 to 1.5 mm², and LiYY reaches 61 cores at 0.14, 0.25 and 0.34 mm². Cores are identified to DIN 47100 with no colour repetition.
Two Builds on One Construction
Conductor, special PVC TI2 insulation and DIN 47100 identification are common to both builds, and both are rated for dry, damp and wet rooms. What separates them is the screen: the CY adds a foil wrap, a tinned drain wire and a tinned copper braid, which is why it is the EMC-optimised build.
| Build | Screen | Application environment |
| TRONIC (LiYY) | None | Dry, damp and wet rooms; not outdoors |
| TRONIC-CY (LiY-CY) | Foil wrap, tinned drain wire, tinned copper braid at approx. 85 % coverage | |
| TRONIC-CY, single-core | Spiral-wrapped tinned copper wire at approx. 85 % coverage |
Terminating the Screen
Installation note: at both ends of the cable the copper screen has to be fully and completely contacted. The screened build needs 10 x OD moving and 5 x OD fixed, against 7.5 x OD and 4 x OD for the unscreened build.
Why the Series Is Specified
DIN 47100 identification
To DIN 47100, with no colour repetition.
Fine-strand copper from 0.5mm²
Class 5 stranding to DIN VDE 0295, BS 6360 and IEC 60228, from 0.5 mm².
PVC TI2 core insulation
Core-to-core capacitance is 120 pF/m at 0.14 mm² and 150 pF/m at 0.25 mm² at 800 Hz.
Small outside diameter
3.5 mm at 2 x 0.14 mm², 2.6 mm on the single-core screened build - small enough for miniature plug bodies.
Defined screen coverage
Foil plus braid at approximately 85 % coverage, with a tinned drain wire to terminate.
LVD compliance metre marking
CE to EU Low Voltage Directive 2014/35/EU; sheath to RAL 7001, length marked every metre.
Typical Applications
These cables are specified where a data run needs the smallest possible outside diameter - in dry, damp and wet rooms, never outdoors.
FAQ
Q: How do I choose between the two builds?
A: By whether the run needs a screen. LiYY has none. LiY-CY is the same construction with a foil wrap and a braid, and is the EMC-optimised build. Neither is suitable for outdoor installation.
Q: : How are the cores identified?
A: To DIN 47100, with no colour repetition.
Q: Does the screen change the diameter much?
A: At 2 x 0.14 mm² the screened build measures 3.9 mm against 3.5 mm unscreened.
Q: Can the cable be run outdoors?
A: No. Both builds are rated for dry, damp and wet rooms and neither is suitable for outdoor installation.
Q: Which end of the screen do I bond?
A: At both ends: the copper screen has to be fully and completely contacted at both ends of the cable.
Q: Is a twisted-pair version available?
A: Yes. Twisted-pair versions are available: PAAR-TRONIC for the unscreened build, PAAR-TRONIC-CY for the screened one.
Hot Tags: tronic liyy and tronic-cy flexible data cable, China tronic liyy and tronic-cy flexible data cable suppliers
Electrical Values by Variant
| Parameter | TRONIC (LiYY) | TRONIC-CY (LiY-CY) |
| Temperature range | Moving installation -5 °C to +80 °C; fixed installation -40 °C to +80 °C | |
| Peak working voltage | 0.14 mm²: 350 V; 0.25 mm² and above: 500 V (not suitable for high-current equipment) | |
| Test voltage core / core | Up to 0.25 mm²: 1200 V; from 0.34 mm²: 2000 V | 1200 V / 1200 V |
| Test voltage core / screen | Not applicable to this build | 800 V / 800 V |
| Breakdown voltage | Up to 0.25 mm²: 2400 V; from 0.34 mm²: 4000 V | Min. 2400 V |
| Mutual capacitance core / core | At 800 Hz: 120 pF/m at 0.14 mm²; 150 pF/m at 0.25 mm² | |
| Mutual capacitance core / screen | Not applicable to this build | At 800 Hz: 240 pF/m at 0.14 mm²; 270 pF/m at 0.25 mm² |
| Characteristic impedance | 78 Ohm (approximate value) | |
| Inductance | Approx. 0.65 mH/km | |
| Coupling resistance | Not applicable to this build | Max. 250 Ohm/km |
| Minimum bending radius | Moving installation 7.5 x outer Ø; fixed installation 4 x outer Ø | Moving installation 10 x outer Ø; fixed installation 5 x outer Ø |
| Insulation resistance | Min. 20 MOhm x km | |
| Radiation resistance | Up to 80 x 10^6 cJ/kg (80 Mrad) | |
| Construction and materials | ||
| Conductor | Bare copper; from 0.5 mm² fine-strand to DIN VDE 0295 class 5, BS 6360 class 5 and IEC 60228 class 5 | |
| Conductor construction | 0.14 mm²: approx. 18 x 0.1 mm; 0.25 mm²: approx. 14 x 0.15 mm; 0.34 mm²: 7 x 0.25 mm | |
| Core insulation | Special PVC TI2, to DIN VDE 0207-363-3 / DIN EN 50363-3 | |
| Core identification | To DIN 47100, no colour repetition | |
| Core lay-up | Cores laid up in layers at the optimum pitch | |
| Screen | None | Foil wrap; drain wire, tinned copper; 1 core: spiral-wrapped tinned copper wire at approx. 85 % coverage; 2 cores and above: tinned copper braid at approx. 85 % coverage |
| Outer sheath | Special PVC TM2, to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 | |
| Sheath colour | Grey (RAL 7001) | |
| Length marking | Metre marking | |
| Materials used in production | Cadmium-free, silicone-free and free of substances that impair paint wetting | |
| Flame retardancy | To DIN VDE 0482-332-1-2, DIN EN 60332-1-2 and IEC 60332-1 (equivalent to DIN VDE 0472 part 804, test method B) | |
| Oil resistance | Strongly oil-resistant; see the table in the technical information section | |
| Approval | CE; complies with EU Low Voltage Directive 2014/35/EU / CE | |
| Application environment | Dry, damp and wet rooms; not suitable for outdoor use | |
| Note | Conductors are made to metric mm²; AWG values are approximate and for reference only | |