TRONIC LiYY and TRONIC-CY Flexible Data Cable

TRONIC LiYY and TRONIC-CY Flexible Data Cable
Details:
Two builds of one data cable: unscreened LiYY, and the EMC-optimised screened LiY-CY. Core insulation is special PVC TI2 under a special PVC TM2 sheath; the screened build is also available as a single core with a spiral-wound screen. Cut to length from factory stock.
Standards & Compliance
DIN VDE 0812 | DIN VDE 0295 / BS 6360 / IEC 60228 cl. 5 | DIN 47100 colour code | CE (LVD 2014/35/EU)
Quick Specs
0.14–1.5 mm², 1–61 cores | 350 / 500 V peak | 1200 V test core/core | −5 to +80 °C moving | grey RAL 7001
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of tronic liyy and tronic-cy flexible data cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

1

A Data Cable Sized to the Connector, Not to the Load

 

TRONIC is a data cable, sized by the connector rather than by current. A two-core 0.14 mm² build measures 3.5 mm across the sheath; with foil and braid the same two cores come in at 3.9 mm, and the single-core screened version is 2.6 mm, small enough for miniature plug bodies. Sizes run from 0.14 to 1.5 mm², and LiYY reaches 61 cores at 0.14, 0.25 and 0.34 mm². Cores are identified to DIN 47100 with no colour repetition.

 

2

 Two Builds on One Construction

 

Conductor, special PVC TI2 insulation and DIN 47100 identification are common to both builds, and both are rated for dry, damp and wet rooms. What separates them is the screen: the CY adds a foil wrap, a tinned drain wire and a tinned copper braid, which is why it is the EMC-optimised build.

 

Build Screen Application environment
TRONIC (LiYY) None Dry, damp and wet rooms; not outdoors
TRONIC-CY (LiY-CY) Foil wrap, tinned drain wire, tinned copper braid at approx. 85 % coverage
TRONIC-CY, single-core Spiral-wrapped tinned copper wire at approx. 85 % coverage

 

3

Terminating the Screen

 

Installation note: at both ends of the cable the copper screen has to be fully and completely contacted. The screened build needs 10 x OD moving and 5 x OD fixed, against 7.5 x OD and 4 x OD for the unscreened build.

 

4

Why the Series Is Specified

DIN 47100 identification

To DIN 47100, with no colour repetition.

Fine-strand copper from 0.5mm²

Class 5 stranding to DIN VDE 0295, BS 6360 and IEC 60228, from 0.5 mm².

PVC TI2 core insulation

Core-to-core capacitance is 120 pF/m at 0.14 mm² and 150 pF/m at 0.25 mm² at 800 Hz.

Small outside diameter

3.5 mm at 2 x 0.14 mm², 2.6 mm on the single-core screened build - small enough for miniature plug bodies.

Defined screen coverage

Foil plus braid at approximately 85 % coverage, with a tinned drain wire to terminate.

LVD compliance  metre marking

CE to EU Low Voltage Directive 2014/35/EU; sheath to RAL 7001, length marked every metre.

 

5

Typical Applications

 

These cables are specified where a data run needs the smallest possible outside diameter - in dry, damp and wet rooms, never outdoors.

 

machine-tools-flexible-control-cable-cnc-machining-centre
Machine tools
measurement and control circuits that move freely, without tensile load and without forced movement.
tool-and-equipment-building-wiring-inside-small-equipment
Tool and equipment building
wiring in tools and small equipment.
electronics-and-computers-data-runs-server-rack
Electronics and computers
data runs in electronic and computer equipment.
measurement-and-control-signal-leads-industrial-control-cabinet
Measurement and control
signal leads for measuring and control circuits.
6

FAQ

Q: How do I choose between the two builds?

A: By whether the run needs a screen. LiYY has none. LiY-CY is the same construction with a foil wrap and a braid, and is the EMC-optimised build. Neither is suitable for outdoor installation.

Q: : How are the cores identified?

A: To DIN 47100, with no colour repetition.

Q: Does the screen change the diameter much?

A: At 2 x 0.14 mm² the screened build measures 3.9 mm against 3.5 mm unscreened.

Q: Can the cable be run outdoors?

A: No. Both builds are rated for dry, damp and wet rooms and neither is suitable for outdoor installation.

Q: Which end of the screen do I bond?

A: At both ends: the copper screen has to be fully and completely contacted at both ends of the cable.

Q: Is a twisted-pair version available?

A: Yes. Twisted-pair versions are available: PAAR-TRONIC for the unscreened build, PAAR-TRONIC-CY for the screened one.

 

 

 

Hot Tags: tronic liyy and tronic-cy flexible data cable, China tronic liyy and tronic-cy flexible data cable suppliers

1

Electrical Values by Variant

 

Parameter TRONIC (LiYY) TRONIC-CY (LiY-CY)
Temperature range Moving installation -5 °C to +80 °C; fixed installation -40 °C to +80 °C
Peak working voltage 0.14 mm²: 350 V; 0.25 mm² and above: 500 V (not suitable for high-current equipment)
Test voltage core / core Up to 0.25 mm²: 1200 V; from 0.34 mm²: 2000 V 1200 V / 1200 V
Test voltage core / screen Not applicable to this build 800 V / 800 V
Breakdown voltage Up to 0.25 mm²: 2400 V; from 0.34 mm²: 4000 V Min. 2400 V
Mutual capacitance core / core At 800 Hz: 120 pF/m at 0.14 mm²; 150 pF/m at 0.25 mm²
Mutual capacitance core / screen Not applicable to this build At 800 Hz: 240 pF/m at 0.14 mm²; 270 pF/m at 0.25 mm²
Characteristic impedance 78 Ohm (approximate value)
Inductance Approx. 0.65 mH/km
Coupling resistance Not applicable to this build Max. 250 Ohm/km
Minimum bending radius Moving installation 7.5 x outer Ø; fixed installation 4 x outer Ø Moving installation 10 x outer Ø; fixed installation 5 x outer Ø
Insulation resistance Min. 20 MOhm x km
Radiation resistance Up to 80 x 10^6 cJ/kg (80 Mrad)
Construction and materials
Conductor Bare copper; from 0.5 mm² fine-strand to DIN VDE 0295 class 5, BS 6360 class 5 and IEC 60228 class 5
Conductor construction 0.14 mm²: approx. 18 x 0.1 mm; 0.25 mm²: approx. 14 x 0.15 mm; 0.34 mm²: 7 x 0.25 mm
Core insulation Special PVC TI2, to DIN VDE 0207-363-3 / DIN EN 50363-3
Core identification To DIN 47100, no colour repetition
Core lay-up Cores laid up in layers at the optimum pitch
Screen None Foil wrap; drain wire, tinned copper; 1 core: spiral-wrapped tinned copper wire at approx. 85 % coverage; 2 cores and above: tinned copper braid at approx. 85 % coverage
Outer sheath Special PVC TM2, to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1
Sheath colour Grey (RAL 7001)
Length marking Metre marking
Materials used in production Cadmium-free, silicone-free and free of substances that impair paint wetting
Flame retardancy To DIN VDE 0482-332-1-2, DIN EN 60332-1-2 and IEC 60332-1 (equivalent to DIN VDE 0472 part 804, test method B)
Oil resistance Strongly oil-resistant; see the table in the technical information section
Approval CE; complies with EU Low Voltage Directive 2014/35/EU / CE
Application environment Dry, damp and wet rooms; not suitable for outdoor use
Note Conductors are made to metric mm²; AWG values are approximate and for reference only

 