Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of liyy liyy-tp 300v unshielded eu standard data cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Lead Paragraph
LiYY is the unshielded pvc data cable that the trade orders as a liyy cable, a liyy kabel or a liy cable. The family has two builds and they differ in one place only. LiYY is the plain bunched construction: a bare soft copper conductor, PVC TI2 insulation and a PVC TM2 sheath, rated 300 V U₀/U. LiYY-TP is the same cable with the cores paired and the pairs laid up together, which is what the TP stands for. Both builds are appointed for the internal wiring of computing systems, electronic control equipment, office machines and measuring equipment in tool manufacturing and the mechanical industry, where they serve as control and signal cables. Twisted pairs or a plain bunch is the whole of the decision, and what follows from it is set out below. Fixed installation takes a 6 × outer diameter bend radius over −10 °C to +80 °C and moving installation 13 × outer diameter over −5 °C to +80 °C, identically on both builds. Cores and sheath are produced to the customer's colour requirement, and both compounds can be supplied in alternative grades to the same requirement.
Twisted Pairs or Plain Bunched - the One Decision Inside the LiYY Family
Bunched cores: the compact answer
LiYY lays its cores in a plain bunch, the most compact way to bring a large core count into one cable. It suits a short run between two enclosures where no adjacent pair couples into it.
Twisted pairs: interference cancels before it reaches the terminals
LiYY-TP pairs the cores two by two. Twisting turns a pair into a loop whose conductors see the same external field, so what one picks up largely cancels on the other; that is what reduces crosstalk, and it is why a route that needs a narrow space, a small diameter and a small bend radius often needs no additional screen at all.
Indoor only
One limit comes with the twisted-pair build: it is not permitted for outdoor use. Everything else is common to the two - bare soft copper conductor, PVC TI2 insulation, PVC TM2 sheath, 300 V U0/U, 80 °C maximum conductor temperature, 6 x OD fixed over -10 °C to +80 °C and 13 x OD moving over -5 °C to +80 °C.
Where the route does need a screen, the shielded member of the same data-cable range, LiYCY, carries a tinned copper braid over the same cores.
Typical Applications
Four routes carry this build: panels and enclosures in tool-making and machine-tool plants, computer and electrical systems, measuring and control circuits, and the small sizes that terminate in miniature plugs.




Where the route does need a screen, the shielded member of the same data-cable range, LiYCY, carries a tinned copper braid over the same cores.
Why Specify LiYY or LiYY-TP
Twisted pairs - the whole of the difference
On LiYY-TP the cores are paired and the pairs laid up together, so interference picked up on one conductor of a pair largely cancels on the other. That is what reduces crosstalk, and it is why this build can be specified with no additional screen in many applications: a twisted-pair data cable without a braid.
01
A 300 V rating shared by the two builds
Both carry U₀/U 300 V and an 80 °C maximum conductor temperature, so one specification and one installation table cover either build.
02
Cutting and stripping are part of the specification
The insulation thickness is stated alongside the ratings, together with easy cutting and easy stripping, because those decide how the cable behaves on the bench rather than in the drawing.
03
Flame retardant to IEC 60332.1
Flame performance is a tested property rather than an unstated one.
04
Chemical performance stated at the outset
Good chemical resistance is declared for the range; resistance to oil, cold, acid, alkali and solvent is available as an option - name it on the enquiry where a run passes through a wash-down area or a fluid.
05
Frequently Asked Questions
Q: What is the difference between LiYY and LiYY-TP?
A: The lay-up of the cores. LiYY bunches its cores; LiYY-TP pairs them and lays the pairs up together. Rated voltage, conductor temperature, ambient range, bend radii, insulation and sheath are identical on the two builds.
Q: What is the minimum bend radius?
A: Fixed installation takes 6 × outer diameter and moving installation 13 × outer diameter, both measured on the cable outer diameter. The figures are the same for the two builds.
Q: What ambient temperature range applies?
A: Fixed installation is rated −10 °C to +80 °C and moving installation −5 °C to +80 °C, with a maximum conductor operating temperature of 80 °C.
Q: Can LiYY-TP be installed outdoors?
A: No. The twisted-pair build is not permitted for outdoor use; where a route leaves the enclosure, a build rated for those conditions must be selected instead.
Q: Does a twisted-pair data cable still need a screen?
A: Not always. The pairs cancel the interference that reaches them, and in many applications no additional screen is needed. Where a screen is mandatory, the shielded member of the data-cable range carries it.
Q: How do I specify the size?
A: By core count and conductor cross-section together, because that is what the part-number schedules are organised on; the two figures are also what a liyy cable specification enquiry turns on. Core colours and compounds are made to order, so the part number identifies the construction rather than a fixed colour scheme. Metric cross-sections are the primary figure; any imperial equivalent is a nearest-area conversion and is not interchangeable with a cable specified in AWG.
Requesting LiYY Cable and Finished Harnesses
Both builds are supplied cut to length against the drawing, and the same cable can be delivered as a finished harness for lines that would rather receive terminated assemblies than coils. State the build - plain bunched or twisted pair - together with the conductor cross-section and the core count, since that is what the schedules are organised on, and the packing format where the length is to arrive coiled or on a drum. Cable and assembly are quoted together rather than as two transactions.
Hot Tags: liyy liyy-tp 300v unshielded eu standard data cable, China liyy liyy-tp 300v unshielded eu standard data cable suppliers
Rated Voltage, Thermal Limits and Flame Retardancy
| Parameter | Rating |
| Rated voltage U₀/U | 300 V |
| Maximum conductor operating temperature | 80 °C |
| Ambient temperature, fixed installation | −10 °C to +80 °C |
| Ambient temperature, moving installation | −5 °C to +80 °C |
| Flame retardancy | Tested to IEC 60332.1 |
| Chemical resistance | Good chemical resistance; resistance to oil, cold, acid, alkali and solvent is available as an option |
| Cutting and stripping | Insulation thickness stated with the ratings; easy to cut and easy to strip |
| Reference standards | UL758 and DIN VDE 0281; conductor to DIN VDE 0295 cl.5 / IEC 60228 cl.5 |
Construction by Build - Bunched and Twisted Pair
| Element | LiYY - plain bunched | LiYY-TP - twisted pair |
| Conductor | Bare soft copper conductor | |
| Insulation | PVC TI2 polyvinyl chloride | |
| Core lay-up | Cores laid up in a plain bunch | Cores paired two by two, the pairs laid up together |
| Sheath | PVC TM2 polyvinyl chloride | |
| Core and jacket colour | Produced to the customer's colour requirement | |
| Insulation and sheath material | Alternative grades to the customer's requirement | |