M12 Cable

M12 Cable
Details:
M12 sensor cable with A, B, D, T, S, K, L and X coding on 3 to 17-pin inserts to IEC 61076-2-101, sealed to IP67 and rated −25 °C to +85 °C, in a PVC, PUR or weld-spatter resistant jacket. Cut to length from factory stock.
Standards & Compliance
IEC 61076-2-101 | IP67 | UL94 V0 | Gold-plated copper alloy contacts
Quick Specs
3–17 pin (signal), 4–5 pin (power) | 4 A / 2 A / 1.5 A / 12–16 A | 250 / 125 / 60 / 63 / 630 V | IP67, −25 to +85 °C | PVC, PUR or weld-spatter jacket
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of m12 cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

What Is an M12 Cable?

 

 

An M12 cable is a pre-assembled cable fitted with an M12×1 circular connector at one or both ends. In this product, the M12 interface is combined with the required contact count, cable construction and pinout to connect industrial sensors and actuators.
 
"M12" identifies the connector interface, not a complete cable specification. Before quotation, the mating connector, contact count, gender, keying, wiring, cable type and electrical requirements must be confirmed together.
 

Built as a Cable Assembly, Not a Loose Connector

 

 

The connector, cable, pin assignment, overmolded strain relief and finished length are supplied as one assembly. This reduces on-site wiring work and gives the customer one defined part for installation and replacement.
 

Available Configurations

 

 

Configuration Available Options Information Required
Coding A-coded for the sensor/actuator configurations on this page Must match the mating interface on the device
Connector gender Male or female Confirm against the mating end on the device; do not judge by appearance alone
Connector style Straight or right-angle For right-angle versions, confirm the cable exit direction relative to the key position
Contact count 3, 4, 5, 8, 12 or 17 contacts by configuration Per the device interface and the approved pin assignment
Cable ends Single-ended flying lead or M12-to-M12 For double-ended versions, confirm the gender, style and pin mapping at both ends
Shielding Shielded or unshielded For shielded versions, specify how the shield is terminated
Cable jacket PVC, PUR or weld-spatter-resistant cable Select according to bending, abrasion, oil and weld-spatter conditions
Finished length 1 m catalog example; custom lengths available Provide the measuring basis and the length tolerance
Pinout Built to the approved pin assignment Provide the device manual, pinout drawing or wiring diagram
Mold and cable color Standard colors and reviewed custom colors Color does not indicate coding or pin identification
Marking Standard branding, no logo or reviewed custom marking by configuration Provide the artwork for custom marking and confirm compliance
 
Not every option can be combined with every contact count. KABASI will confirm the available construction after reviewing the device interface and cable requirements.
 

Connector Styles

 
m12-straight-female-cable-overmolded-connector

Straight Female M12 Cable

For installations where the cable can exit directly behind the mating interface. Available as a single-ended cable or as one end of an M12-to-M12 assembly.
m12-straight-male-cable-overmolded-connector

Straight Male M12 Cable

For direct sensor and actuator interconnections. Confirm the mating side and pin
assignment before selecting the cable.
m12-right-angle-female-cable-overmolded-connector

Right-Angle Female M12 Cable

For restricted installation space or controlled cable routing. The cable-exit direction in relation to the connector keyway should be defined in the drawing.
m12-straight-male-cable-overmolded-connector

Right-Angle Male M12 Cable

For installations where a straight cable exit would interfere with nearby equipment or enclosure
space. Connector orientation must be approved before production.

Single-Ended and Double-Ended Options

 

 

  • Single-Ended M12 Cable with Flying Leads

 
One end is terminated with an overmolded M12 connector, while the opposite end is prepared as flying leads for connection to terminals, internal wiring or customer-specified equipment. State the strip length, conductor treatment and wire identification when required.
 
  • M12-to-M12 Cable Assembly

 
Both ends are terminated with M12 connectors in the approved male/female and straight/right-angle combination. Provide the pin-to-pin map rather than assuming a straight-through connection.

 

Cable and Shielding Selection

 

 

PVC Cable

PVC cable is available as one of the standard jacket options. Confirm the required flexibility, oil resistance, temperature and installation environment against the selected cable datasheet.
 

PUR Cable

PUR cable can be selected where the approved cable specification better matches abrasion, oil or movement requirements. Dynamic-flex performance must be confirmed from the exact cable construction rather than inferred from the jacket name alone.
 

Weld-Spatter-Resistant Cable

Weld-spatter-resistant cable is available for reviewed applications exposed to welding environments. State the actual exposure conditions so that the cable and connector construction can be evaluated together.
 
Shielded or Unshielded
Use an unshielded assembly where the device specification does not require shielding. For shielded assemblies, define the shield construction and whether it is terminated at one end, both ends or through the connector interface.
 

Typical Applications

 

 

 

application-scenarios-landscape-three-per-row

 

Specification Review Process

 

 

Step 1 ― Confirm the Mating Interface
 
We review the device interface, contact count, connector gender and mechanical style before selecting the assembly construction.
 
Step 2 ― Confirm the Pinout and Cable
 
The pin assignment, cable jacket, conductor size, shielding, length and tolerance are defined in the product specification or drawing. Missing information is returned for confirmation rather than assumed.
 
Step 3 ― Quote the Defined Assembly
 
The quotation is prepared against the confirmed configuration, quantity, marking and testing requirements. Material availability and any sample arrangement are confirmed with the quotation.
 
Step 4 ― Build to the Approved Revision
 
Production follows the approved part number, drawing revision, cable specification and pinout. Changes require review before release.

 

FAQ

 

 

Q: Is an M12 cable the same as an M12 sensor cable?

A: M12 describes the connector interface, while sensor cable describes the application. This page covers M12 cable assemblies configured for sensor and actuator connections. M12 power and RJ45-to-M12 data products are handled on separate pages.

Q: Can I order a custom cable length?

A: Yes. The catalog uses 1 m as a common ordering example and indicates that custom lengths are available. State the finished length, measurement reference and tolerance in your inquiry.

Q: Are straight and right-angle connectors available?

A: Yes. Straight and right-angle male and female overmolded versions are available. For right-angle connectors, define the cableexit direction relative to the keyway.

Q: Can the cable be shielded?

A: Yes. Shielded versions are available for selected contact configurations. State the required shield treatment and grounding method so that the connector and cable can be reviewed together.

Q: Can you supply an M12-to-M12 cable?

A: Yes. Male/female and straight/right-angle combinations can be reviewed. Provide the connector definition at both ends and the required pin-to-pin map.

Q: Which cable jacket should I choose?

A: Choose PVC, PUR or weld-spatter-resistant cable according to the actual bending, abrasion, oil, moisture and welding conditions. Where a defined resistance level or flex life is required, the exact cable datasheet must be confirmed

Q: Do you supply M12 power or RJ45-to-M12 cables?

A: These are separate product types with different electrical and transmission requirements. Please use the dedicated M12 Power Cable or RJ45 to M12 Cable product page when those pages are available.

 

Hot Tags: m12 cable, China m12 cable suppliers

Signal Codings - Materials and Technical Data

 

 

Parameter

3-pin

4-pin

5-pin

8-pin

12/17-pin

Standard

IEC 61076-2-101

IEC 61076-2-101

IEC 61076-2-101

IEC 61076-2-101

IEC 61076-2-101

Rated current

4 A

4 A

4 A

2 A

1.5 A

Rated voltage

250 V

250 V

125 V

60 V

60 V

Overvoltage category

II

II

II

II

II

Contact resistance

≤10 mΩ

≤10 mΩ

≤10 mΩ

≤10 mΩ

≤10 mΩ

Insulation resistance

>100 MΩ

>100 MΩ

>100 MΩ

>100 MΩ

>100 MΩ

Pollution degree

3

3

3

3

3

Degree of protection

IP67

IP67

IP67

IP67

IP67

Ambient temperature

−25 to +85 °C

−25 to +85 °C

−25 to +85 °C

−25 to +85 °C

−25 to +85 °C

Coding

A/B/D

A/B/D

A/B/D

A

A

Overmould

TPU

TPU

TPU

TPU

TPU

Contact insert

PA

PA

PA

PA

PA

Contact / plating

Cu alloy/Au

Cu alloy/Au

Cu alloy/Au

Cu alloy/Au

Cu alloy/Au

Flame rating, UL94

V0

V0

V0

V0

V0

Jacket

PVC / PUR / weld-spatter

PVC / PUR / weld-spatter

PVC / PUR / weld-spatter

PVC / PUR / weld-spatter

PVC / PUR / weld-spatter

Shield

Unshielded

Unshielded

Unshielded

Unshielded

Unshielded

Conductor

0.34 mm²/22 AWG

0.34 mm²/22 AWG

0.34 mm²/22 AWG

0.25 mm²/24 AWG

0.14 mm²/26 AWG

Overmould colour

Blue by default; black, orange or another colour

Jacket colour

Black by default; grey, green, orange or another colour

 

Power Codings - Materials and Technical Data

 

 

Parameter

T (4-pin)

S (4-pin)

K (5-pin)

L (5-pin)

Standard

IEC 61076-2-101

IEC 61076-2-101

IEC 61076-2-101

IEC 61076-2-101

Rated current

12 A

12 A

12 A

16 A

Rated voltage

63 V

630 V

630 V

63 V

Overvoltage category

II

II

II

II

Contact resistance

≤10 mΩ

≤10 mΩ

≤10 mΩ

≤10 mΩ

Insulation resistance

>100 MΩ

>100 MΩ

>100 MΩ

>100 MΩ

Pollution degree

3

3

3

3

Degree of protection

IP67

IP67

IP67

IP67

Ambient temperature

−25 to +85 °C

−25 to +85 °C

−25 to +85 °C

−25 to +85 °C

Coding

T

S

K

L

Overmould

TPU

TPU

TPU

TPU

Contact insert

PA

PA

PA

PA

Contact / plating

Cu alloy/Au

Cu alloy/Au

Cu alloy/Au

Cu alloy/Au

Flame rating, UL94

V0

V0

V0

V0

Jacket

PVC / PUR / weld-spatter

PVC / PUR / weld-spatter

PVC / PUR / weld-spatter

PVC / PUR / weld-spatter

Shield

Unshielded

Unshielded

Unshielded

Unshielded

Conductor

1.5 mm²/16 AWG

1.5 mm²/16 AWG

1.5 mm²/16 AWG

1.5 mm²/16 AWG

Overmould colour

Black by default; blue, orange or another colour

Jacket colour

Black by default; grey, green, orange or another colour

 

The Four Body Forms

 

 

Four body forms are two polarities crossed with two cable exits. FS is the straight female, FR the right-angle female, MS the straight male and MR the right-angle male. The female bodies mate with a device-side male thread; the male bodies go into a female socket. Where the cable has to be terminated on site, the same insert is available as a PG7 or PG9 field-wireable plug with a screw terminal, rated −40 °C to +85 °C.

 

Mounting type

Polarity

Cable exit

FS

Female (socket)

Straight

FR

Female

Right-angle

MS

Male (pin)

Straight

MR

Male

Right-angle

 

Pin Colour Code

 

 

Coding

Pins

Colour code

A/B/D

3

1 brown, 2 blue, 3 black

A/B/D

4

1 brown, 2 white, 3 blue, 4 black

A/B/D

5

1 brown, 2 white, 3 blue, 4 black, 5 grey

A

8

1 white, 2 brown, 3 green, 4 yellow, 5 grey, 6 pink, 7 blue, 8 red

A

12

1 brown, 2 blue, 3 white, 4 green, 5 pink, 6 yellow, 7 black, 8 grey, 9 red, 10 violet, 11 grey-pink, 12 red-blue

A

17

As 12-pin, plus 13 white-green, 14 brown-green, 15 white-yellow, 16 yellow-brown, 17 white-grey

T

4

1 brown, 2 white, 3 blue, 4 black

S

4

1 black, 2 black, 3 black, 4 yellow-green (PE)

K

5

1 to 4 black, PE yellow-green

L

5

1 brown, 2 white, 3 blue, 4 black, PE grey

Send Inquiry