Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of unitronic lihch data cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Lead Paragraph
UNITRONIC LiHCH is a screened halogen-free data cable for buildings where sensitive signals share space with power. A high-coverage tinned copper braid acts as a Faraday cage, diverting inverter hash and inductive switching spikes to ground, while concentric-laid cores with low mutual capacitance keep 4–20 mA transmitter loops, RTD inputs and encoder channels clean. The LSZH polyolefin insulation and jacket satisfy IEC 60754-1/2 for acid-gas-free combustion and IEC 61034-2 for low smoke density, so hospitals, data centres and airport terminals get telemetry integrity and fire safety from one cable. Forty configurations run from 2-core 0.14 mm² to 3-core 1.5 mm². KABASI supplies precision-cut reels and pre-tested assemblies with 360° EMC terminations.
Select Your Variant
Screened Data Cable Comparison: LiHCH (Concentric Layer) vs. LiHCH (TP) (Twisted Pair)
|
Engineering Comparison Dimension |
UNITRONIC LiHCH (Concentric Layered) |
UNITRONIC LiHCH (TP) (Twisted Pair) |
System Engineering Decision Matrix |
|
Internal Conductor Geometry |
Cores stranded in concentric circular layers |
Cores paired and twisted (TP) with calculated lay lengths |
Specify LiHCH for discrete I/O, analogue 4–20 mA and display runs; specify LiHCH (TP) where adjacent channels carry dissimilar signal levels. |
|
Internal Crosstalk Attenuation |
Moderate channel-to-channel capacitive coupling |
Near-end crosstalk (NEXT) canceled by balanced magnetic field decoupling |
Choose LiHCH (TP) where adjacent core channels carry disparate signal amplitudes or asynchronous digital pulses. |
|
Cable Outer Diameter & Space |
Noticeably more compact across identical core counts (e.g. 4-core 0.25 is 5.2 mm) |
Slightly larger profile (e.g. 2 x 2 x 0.25 is 6.5 mm) |
LiHCH is ideal where multi-channel cable trays are space-constrained and cross-pair decoupling is not required. |
|
Stripping & Termination Speed |
Rapid stripping; single outer sheath and unified braid cut |
Requires pair separation and individual pair unwinding |
LiHCH delivers significantly faster wiring throughput in standard PLC marshaling cabinets. |
Typical Applications




Why Choose UNITRONIC LiHCH Series
|
Advantage |
What it means on site |
|
Dense Tinned Copper Braid Guarantees High-Frequency EMC Protection |
Suppresses high-frequency electrical hash and inverter noise, preventing signal corruption in dense factory floors and medical hubs. |
| Zero-Halogen Fire Safety - IEC 60754-1/-2 and IEC 61034-2 |
Releases no corrosive hydrogen chloride fumes (IEC 60754-1/2) and preserves optical visibility (IEC 61034-2), ensuring uncompromised life safety across public transportation hubs. |
|
Broad 40-Item Directory Spans from 0.14 mm² to 1.50 mm² |
Offers unmatched channel scalability from miniature 0.14 mm² transducer wires up to robust 1.5 mm² control lines, allowing facility-wide specification under one standardized family. |
|
Low-Capacitance Polyolefin Insulation Preserves Pulse Sharpness |
Mutual capacitance of 80 nF/km (core/core) prevents pulse front-edge degradation, ensuring reliable analog readings and crisp digital telemetry over extended cable runs. |
Electromagnetic Compatibility (EMC): What the Braid Does and How to Terminate It
Electromagnetic interference in industrial and medical facilities predominantly originates from switching transistors in frequency inverters, heavy relay contact arcing, and radio transmitters. UNITRONIC LiHCH utilizes a heavy tinned copper braid shield to enforce signal immunity across a broad frequency spectrum:
|
EMC Shielding Criterion |
Physical Mechanism in UNITRONIC LiHCH |
Performance Threshold & Value |
Operational Benefit in Real-World Installations |
|
Transfer Impedance |
Current redistribution across interwoven copper wire strands |
≤ 250 Ω/km at 30 MHz high-frequency test |
Prevents high-frequency common-mode noise voltages from penetrating internal signal cores. |
|
Electrostatic Noise Divergence |
Continuous conductive boundary around stranded core lay-up |
Capacitive coupling to shield: ~120 nF/km |
Diverts stray capacitive displacement currents directly to enclosure ground bus before reaching sensitive inputs. |
|
Braid Optical Coverage |
Tightly woven fine tinned copper wire weave |
Nominal optical coverage ≥ 80% to 85% |
Eliminates high-frequency aperture leakage, outperforming simple spiral wraps or thin unbacked foil. |
|
360° Termination Interface |
Compatible with EMC-compliant brass cable glands |
Low-resistance 360-degree bonding ring contact |
Eliminates inductive "pigtail" drain wire resonances that otherwise destroy high-frequency shield efficacy. |
Deploying UNITRONIC LiHCH guarantees that sensitive analog instrumentation operates without erratic drift or false threshold alarms even when installed in close proximity to commercial building elevators and chiller drives.
Frequently Asked Questions
Q: What is the structural difference between "LiHH" and "LiHCH"?
A: The letter "C" in "LiHCH" indicates a copper braided screen ("Cu-Geflecht" in German cable nomenclature). While LiHH consists of bare unshielded insulated cores beneath a halogen-free jacket, LiHCH adds an overall tinned copper wire braided screen beneath the outer sheath, providing superior electromagnetic shielding against external electrical noise.
Q: Why is tinned copper wire preferred over bare copper for the braided screen?
A: Tinned copper wire offers substantially higher resistance to atmospheric oxidation, moisture corrosion, and corrosive industrial atmospheres. Tin plating also enhances solderability when attaching shield ground leads and ensures long-term low contact resistance within 360° EMC cable gland clamping cones.
Q: How should the shield of UNITRONIC LiHCH be grounded in an analog 4–20 mA loop?
A: For low-frequency analog sensor loops (4–20 mA or 0–10 V), the shield should generally be connected to ground at one end only (typically at the PLC or DCS cabinet instrument earth bus). This prevents power-frequency ground loop currents from circulating through the shield and inducing 50 Hz/60 Hz hum onto sensitive analog readings.
Q: Can UNITRONIC LiHCH be installed in continuous cable drag chains?
A: No. UNITRONIC LiHCH is engineered for fixed installations or occasional non-continuous flexing (minimum bending radius 10 × OD). For continuous high-speed movement inside automated drag chains, specify UNITRONIC FD CP (TP) plus or ÖLFLEX CHAIN families designed specifically for millions of flexural cycles.
Q: Does the shield add significant weight and stiffness compared to unshielded LiHH?
A: Yes. The tinned copper braid increases both cable weight and mechanical rigidity. For example, 4-core 0.25 mm² unshielded LiHH weighs 28 kg/km with a 4.5 mm diameter, whereas screened LiHCH weighs 35 kg/km with a 5.2 mm diameter. However, this modest profile increase delivers complete high-frequency noise immunity.
Hot Tags: unitronic lihch data cable, China unitronic lihch data cable suppliers
Electrical, Mechanical & Screen Construction Ratings
|
Technical Parameter |
Standard Reference & Certified Value |
|
Conductor Stranding |
Fine multi-strand bare copper; 0.34 mm² is 7 strands, based on VDE 0812 |
|
Core Insulation |
Special halogen-free polyolefin compound (reduced mutual capacitance) |
|
Screening Structure |
Tinned copper wire braided screen |
|
Core Identification |
DIN 47100 standard color code without color repetition |
|
Core Lay-Up |
Cores laid up under an overall braid |
|
Outer Sheath Material |
Special halogen-free flame-retardant compound (LSZH), pebble grey (similar to RAL 7032) |
|
Peak Operating Voltage |
250 V (for low-voltage data, signal and instrumentation circuits) |
|
Dielectric Test Voltage |
1200 V |
|
Mutual Capacitance (Core/Core) |
Approx. 80 nF/km |
|
Mutual Capacitance (Core/Screen) |
Approx. 120 nF/km |
|
Inductance |
Approx. 0.65 mH/km |
|
Minimum Bending Radius |
Occasional flexing: 10 × outer diameter | Fixed installation: 6 × outer diameter |
|
Temperature Range (Flexing) |
−5 °C to +70 °C |
|
Temperature Range (Fixed) |
−30 °C to +80 °C |
|
Halogen Acid Gas Emission |
IEC 60754-1 (< 5 mg/g HCl, zero halogens) |
|
Corrosiveness of Combustion Gases |
IEC 60754-2 (pH ≥ 4.3; electrical conductivity ≤ 10 µS/mm) |
|
Smoke Density & Visibility |
IEC 61034-2 (optical light transmittance ≥ 60%) |
|
Toxicity of Combustion Fumes |
EN 50305 low toxicity index compliance |
|
Flame Retardance |
IEC 60332-1-2 single-cable vertical flame propagation test |
Screen Earthing & 360° Shield Termination Rules for Noise-Free Signal Telemetry
A high-quality copper braid shield only delivers its theoretical attenuation when correctly bonded to the enclosure ground at termination points:
|
Earthing Practice |
Correct Engineering Execution |
Improper Shortcut to Avoid |
Technical Consequence on Signal Integrity |
|
360° Circumferential Clamping |
Use EMC brass cable glands with conductive spring contact rings that clamp the braid circumferentially around its entire 360° perimeter |
Do not twist the braid into a thin wire strand ("pigtail") and screw it under a generic ground lug |
Pigtails introduce high parasitic inductance (L ≈ 1 nH/mm); at 30 MHz, a 50 mm pigtail adds ~9.4 Ω impedance, rendering the shield useless against HF noise. |
|
Single-Point vs. Dual-Point Earthing |
For low-frequency analog circuits (0–10V, 4–20mA), ground the braid at the controller end only; for high-frequency digital telemetry, ground at both ends with equipotential bonding |
Never ground both ends when significant ground potential differences (> 1 V) exist between field sensors and controllers |
Ground potential differentials cause large power-frequency loop currents to flow through the braid, injecting 50/60 Hz hum directly into analog inputs. |
|
Continuity Across Enclosure Bulkheads |
Maintain shield continuity through partition walls using dedicated feedthrough EMC glands or feedthrough connectors |
Never break the shield and allow bare cores to bridge bulkheads over open air |
Unshielded gaps allow radiated motor drive emissions to bypass the cable screen entirely. |
|
Shield Separation from Low-Z Ground Bus |
Connect the enclosure ground bus bar directly to clean instrument earth (PE) with impedance < 1.0 Ω |
Do not share signal shield ground bars with high-power inverter motor grounding studs |
Prevents heavy motor fault currents from back-feeding into sensitive instrument cable braids. |
Metric to AWG Reference Notice
UNITRONIC LiHCH is manufactured to metric cross-sections with equivalent AWG ratings recognized for international engineering reference.
|
Metric Section (mm²) |
Equivalent North American AWG Designation |
|
0.14 |
26 |
|
0.25 |
24 |
|
0.34 |
22 |
|
0.5 |
20 |
|
0.75 |
18 |
|
1.0 |
17 |
|
1.5 |
16 |
UNITRONIC LiHCH — Part Number Directory
Halogen-free screened flexible data cable with DIN 47100 color code and overall copper braid. Selected catalogue listing from 0037302 to 0037903 with integrated AWG equivalents.
|
Part No. |
Cores × mm² |
Equivalent AWG |
Outer Diameter (mm) |
Copper Index (kg/km) |
Total Weight (kg/km) |
|
0037302 |
2 x 0.14 |
26 AWG |
4.1 |
12.0 |
22 |
|
0037308 |
8 x 0.14 |
26 AWG |
6.0 |
26.0 |
41 |
|
0037325 |
25 x 0.14 |
26 AWG |
8.7 |
63.0 |
149 |
|
0037402 |
2 x 0.25 |
24 AWG |
4.7 |
15.0 |
25 |
|
0037407 |
7 x 0.25 |
24 AWG |
6.2 |
32.0 |
52 |
|
0037425 |
25 x 0.25 |
24 AWG |
10.9 |
114.0 |
172 |
|
0037502 |
2 x 0.34 |
22 AWG |
5.1 |
17.0 |
30 |
|
0037508 |
8 x 0.34 |
22 AWG |
8.0 |
45.0 |
84 |
|
0037525 |
25 x 0.34 |
22 AWG |
12.1 |
144.0 |
259 |
|
0037602 |
2 x 0.5 |
20 AWG |
5.8 |
29.0 |
38 |
|
Part No. |
Cores × mm² |
Equivalent AWG |
Outer Diameter (mm) |
Copper Index (kg/km) |
Total Weight (kg/km) |
|
0037605 |
5 x 0.5 |
20 AWG |
7.2 |
50.0 |
76 |
|
0037608 |
8 x 0.5 |
20 AWG |
8.9 |
75.0 |
135 |
|
0037618 |
18 x 0.5 |
20 AWG |
11.7 |
134.0 |
239 |
|
0037702 |
2 x 0.75 |
18 AWG |
6.2 |
35.0 |
45 |
|
0037704 |
4 x 0.75 |
18 AWG |
7.2 |
56.0 |
80 |
|
0037802 |
2 x 1.0 |
17 AWG |
6.5 |
43.0 |
72 |
|
0037804 |
4 x 1.0 |
17 AWG |
7.5 |
68.0 |
109 |
|
0037807 |
7 x 1.0 |
17 AWG |
8.8 |
118.0 |
171 |
|
0037902 |
2 x 1.5 |
16 AWG |
7.3 |
58.0 |
90 |
|
0037903 |
3 x 1.5 |
16 AWG |
7.7 |
74.0 |
115 |