H03VVH2-F — 300/300 V Flat PVC Sheathed Cord

H03VVH2-F — 300/300 V Flat PVC Sheathed Cord
Details:
H03VVH2-F is the flat two-core cord of the 300/300 V PVC sheathed family. The H2 suffix is the oblate profile: two fine-wired cores to DIN VDE 0295 cl.5, each insulated in PVC TI2, laid side by side and closed inside one PVC TM2 sheath, so the cord presents a width and a height instead of a single diameter.
Standards & Compliance
EN 50525 reference standard | DIN VDE 0295 cl.5 conductor | PVC TI2 insulation / PVC TM2 sheath | IEC 60332.1 flame test
Quick Specs
300/300 V | 70 °C | 0.5 and 0.75 mm2, 2 cores | Oblate profile (H2) | Fine-wired bare copper, cl.5
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of h03vvh2-f — 300/300 v flat pvc sheathed cord in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

H03VVH2-F cord is the flat profile of the 300/300 V sheathed cord: two cores side by side under one sheath, rather than a bundle inside a round one. What changes is the envelope and the handling, not the electrical construction. The conductors are the same fine-wired bare copper to DIN VDE 0295 cl.5, the core insulation is PVC TI2, the sheath is PVC TM2, and the rated conductor temperature is 70 °C. Only two cores are offered, at 0.5 mm2 and 0.75 mm2, and the flame requirement is IEC 60332.1.

 

A Cord Sold on Two Dimensions

 

A flat cord does not have an outer diameter, it has a width and a height. The 0.5 mm2 version measures 3.1 mm by 5.0 mm and the 0.75 mm2 version 3.3 mm by 5.4 mm. Both figures are needed at the design stage, because the two of them answer different questions: the height is what a panel gap or a housing entry has to clear, and the width is what the cord occupies along a surface and what a strain relief or a clip has to span.

 

The tolerance is applied to both dimensions, at plus or minus 0.4 mm on these lighter entries. A designer who allows for the nominal height alone can be caught out by the upper limit of the tolerance on a tight entry, so the interval rather than the nominal is the safer number to work from.

 

Where the Flat Profile Pays

 

Indoor Lighting Wiring

Covers three types of indoor lighting circuits: residential buildings, lighting service halls and portable lighting devices.

building-wiring-indoor-lighting-circuit-residential-service-hall-and-portable-lighting-2848x1600
building-wiring-kitchen-high-temperature-area-heat-resistant-cable-2848x1600

High-Temperature Area Wiring

Suitable for high-temperature indoor application environments such as kitchens.

 

Why Two Cores and Not Three

 

The oblate construction on this range is a two-core construction. A third core would make the profile a three-lobed shape rather than a ribbon, and the flat advantage - a low, stable build height - would be lost. Where a protective conductor has to be carried, the round three-core cord of the same tier is the construction to specify, at the same 300/300 V rating and in the same 0.5 mm2 and 0.75 mm2 sections.

 

Specification Questions

 

Q: How is the size of a flat cord written?

A: As a width by a height, in that order, with both figures in mm. The 0.75 mm2 version is written 3.3 mm by 5.4 mm. Quote both when asking for a price or checking an entry, because either one can be the limiting dimension.

Q: Why is there no three-core version?

A: Because the oblate profile is built from two cores laid side by side. Adding a third would change the cross-section from a ribbon to a cluster and remove the low build height that the flat cord is chosen for. Three cores are available in the round cord of the same 300/300 V tier.

Q: What voltage is it rated for?

A: 300/300 V, the same as the round cord of this tier. The profile does not change the rating: U0/U is 300 V to earth on a single insulated core and 300 V between conductors on the complete cord.

Q: What bending radius applies?

A: 6D for fixed installation and 13D where the cord is flexed in service, the same rule the round construction of this tier carries. Because the profile is not circular, state the plane of the bend on the drawing so that the radius is checked against the dimension that is actually being curved.

Q: Can the cores be coloured to a code?

A: Yes. Core and sheath colours are made to the customer requirement. State the core colour code and the sheath colour on the order, and both are confirmed against the finished construction on the quotation.

Q: Can it be supplied as a finished lead?

A: Yes. The flat cord is cut to length, and where a terminated lead is preferred the same construction is assembled to the drawing. Cord and assembly are quoted in one document.

 

Requesting an H03VVH2-F Cord

 

Send the section, the length, the core colour code and the sheath colour, and state the gap or the entry the cord has to pass so that the envelope is checked before the order is confirmed. Where the lead is to be terminated, add the termination and it is quoted alongside the cord.

 

 

Hot Tags: h03vvh2-f — 300/300 v flat pvc sheathed cord, China h03vvh2-f — 300/300 v flat pvc sheathed cord suppliers

Ratings of H03VVH2-F

 

Item Value
Rated voltage U0/U 300/300 V
Conductor Fine-wired bare copper, DIN VDE 0295 cl.5
Core insulation PVC TI2
Outer sheath PVC TM2
Profile Oblate (H2), two cores side by side
Rated conductor temperature 70 °C
Temperature range Fixed -15 to +70 °C; flexing -5 to +70 °C
Bending radius 6D fixed, 13D flexing
Flame test IEC 60332.1
Reference standard EN 50525

 

Envelope by Section

 

Cores Section (mm2) Width (mm) Height (mm) Weight (kg/km)
2 0.5 3.1 5 25
2 0.75 3.3 5.4 32

 

 

Send Inquiry