UNITRONIC Li2YCY (TP) Data Cable

UNITRONIC Li2YCY (TP) Data Cable
Details:
UNITRONIC Li2YCY (TP) screened data cable for RS-485/RS-422: PE insulation, twisted pairs, tinned-copper braid, 0.22–0.5 mm². Li2YCYv (TP) adds a thickened black sheath for indoor/outdoor and direct burial.

Standards & Compliance
VDE 0812 | VDE 0881 conductor | DIN 47100 colour code | IEC 60332-1-2 | ETIM EC000104

Quick Specs
0.22–0.5 mm², 1–10 pairs | mutual capacitance max. 70 nF/km (0.5 mm²: 75) | 2000 V core/core, 1000 V core/screen | 100 ± 15 Ω characteristic impedance | −40 to +80 °C fixed
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of unitronic li2ycy (tp) data cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

UNITRONIC Li2YCY (TP) is a low-capacitance data cable for RS-422 and RS-485 links where signal integrity over distance decides whether the installation works. Polyethylene insulation and twisted pairs hold mutual capacitance to 60 nF/km at 800 Hz, while an overall tinned-copper braid keeps interference away from the pair. It carries data systems up to 10 Mbit/s and suits fixed installation and occasional flexing indoors, in dry or damp rooms. A fine-strand conductor version serves tighter routing, and Li2YCYv (TP) adds a reinforced black sheath - nominal minimum average wall thickness 1.8 mm - that brings the same electrical performance to outdoor and direct-burial routes. Choose grey Li2YCY (TP) for cabinet and machine wiring, fine-strand where bending space is tight, and black Li2YCYv (TP) wherever the cable leaves the building.

 

Select Your Variant

 

In short: all three share one electrical platform - PE insulation, twisted pairs, tinned-copper braid, 60 nF/km, 100 Ohm. What changes is conductor construction and outer sheath: fine-strand copper for tight bends, reinforced black sheath for outdoor and burial.

 

By Installation Requirement - Panel, Indoor and Buried RS-485 Routes

Requirement

Recommended variant

Why

Standard fixed installation indoors

Li2YCY (TP)

Grey PVC sheath, 1–10 pairs, 0.22–0.5 mm²

Repeated re-termination in a crowded enclosure Li2YCY (TP) fine-strand conductor Fine copper strands, 0.25 mm², 1 to 5 pairs

Outdoor routing or direct burial

Li2YCYv (TP)

Reinforced black sheath, min. average wall 1.8 mm

Long RS-485 bus with many drops

Li2YCY (TP) or Li2YCYv (TP)

60 nF/km mutual capacitance keeps the bus within budget

Damp or humid indoor rooms

Li2YCY (TP)

Rated for dry and damp interior locations

 

By Sheath Colour and Construction

 

Li2YCY (TP)

Li2YCY (TP) fine-strand

Li2YCYv (TP)

Conductor

7-strand copper to VDE 0881

Multi-strand fine copper

7-strand copper to VDE 0881

Outer sheath

PVC, light grey RAL 7032

PVC, light grey RAL 7032

Reinforced, black RAL 9005

Best for

Indoor fixed and occasional flexing

Fine copper, 0.25 mm²

Outdoor and direct burial

 

Typical Applications

 

01cabinet-to-cabinet-wiring-panel-interior-with-plc-i-o-modules-relays-and-blue-control-cores-on-din-rail-control-room-screens-behind

Cabinet to Cabinet: PLC, Drive and Remote I/O

Inside a panel the cable runs from the PLC card to the drive and on to remote I/O, mostly fixed but re-dressed when a module changes. Twisted pairs under PE insulation are what keep the pair's capacitance down over that route.

02analyser-and-sensor-signals-flow-transmitter-with-a-screened-signal-cable-landed-on-its-terminal-box-on-a-blue-machine-frame

Analyser and Sensor Signals

An analyser or a sensor loop puts a small signal on a long pair, and that pair has to bring it back without picking up whatever the drive next to it is switching. The overall tinned-copper braid is the part that keeps the two apart.

03rs-485-and-modbus-rtu-bus-drops-grey-distribution-cabinet-with-breakers-drives-and-terminal-strips-wired-with-blue-cores

RS-485 and Modbus RTU Bus

On an RS-485 or Modbus RTU bus every drop sits on the same pair, so how far the bus reaches is settled by two cable figures: 100 Ohm impedance and 60 nF/km capacitance.

04between-buildings-black-sheathed-cable-ducts-laid-in-an-open-trench-between-two-steel-clad-buildings-one-run-entering-a-wall-penetration

Between Buildings: the Reinforced Black Sheath

Where the run leaves the building or goes into the ground, the grey sheath stops being the right answer. The Yv version keeps the same PE insulation, twisted pairs and braid, and adds a reinforced black sheath - nominal minimum average wall 1.8 mm - for outdoor installation and direct burial.

 

Why Choose UNITRONIC Li2YCY (TP) / Li2YCYv (TP)

 

Li2YCY (TP) Fine-Strand Conductor - 0.25 mm² in 1 to 5 Pairs

01

All Three Variants - Tinned-Copper Braid and VDE 0812 Approval

02

Li2YCYv (TP) - Reinforced Black Sheath for Outdoor and Direct Burial

03

Li2YCY (TP) Fine-Strand Conductor - Tight Bending Radii Without Conductor Stress

04

 

Product Structure

 

Layer

Li2YCY (TP)

Li2YCY (TP) fine-strand

Li2YCYv (TP)

① Conductor

7-strand copper, VDE 0881

Multi-strand fine copper

7-strand copper, VDE 0881

② Core insulation

Polyethylene (PE)

Polyethylene (PE)

Polyethylene (PE)

③ Pairing

Twisted pairs (TP)

Twisted pairs (TP)

Twisted pairs (TP)

④ Screen

Overall tinned-copper braid

Overall tinned-copper braid

Overall tinned-copper braid

⑤ Outer sheath

PVC, light grey RAL 7032

PVC, light grey RAL 7032

Reinforced PVC, black RAL 9005

 

Frequently Asked Questions

 

Q: What does "TP" mean in Li2YCY (TP)?

A: TP stands for twisted pair. The two conductors of each circuit are twisted around each other at a fixed lay length, which keeps the loop area small and makes the pair far less susceptible to magnetic interference than two parallel cores. It also lets the pair carry a defined characteristic impedance of 100 Ohm, which is what RS-422 and RS-485 links are designed around.

Q: Why does low capacitance matter for an RS-485 bus?

A: Capacitance between the conductors acts as a low-pass filter. The higher it is, the more the edges of each bit are rounded off, and the shorter the distance the bus can run before the receiver stops resolving them. Holding mutual capacitance to 60 nF/km at 800 Hz, as this cable does, keeps the edge shape intact over a longer route than a general-purpose control cable would allow.

Q: Li2YCY (TP) or the fine-strand version - which one do I need?

A: Choose the standard 7-strand version unless bending space is the limiting factor. The 7-strand build is available in 1 to 10 pairs and in 0.22, 0.34 and 0.5 mm². Switch to the fine-strand version when the route inside a panel or enclosure is too tight for the standard build - it trades the wider pair range for a conductor that bends more easily without stressing the copper.

Q: When must I specify Li2YCYv (TP) instead?

A: As soon as the cable leaves the building, runs in a trench, or is buried directly in the ground. The grey versions are rated for indoor dry and damp locations only. Li2YCYv (TP) carries a reinforced black sheath with a nominal minimum average wall thickness of 1.8 mm and is the variant intended for outdoor installation and direct burial.

Q: Can I lay the grey versions outdoors?

A: No. The grey sheath is specified for dry and damp interiors, not for burial. Use Li2YCYv (TP) for those routes; it keeps the same electrical core, so nothing about the data performance changes.

Q: Do I have to bond the screen at both ends?

A: That depends on the noise environment. Bonding the braid at both ends gives the best high-frequency shielding but can introduce a low-frequency ground loop where the two ends sit at different earth potentials. In a single building, both ends is the normal choice; across two buildings or a long outdoor run, bond one end directly and the other through a capacitor.

Q: What is the maximum transmission rate?

A: The series is specified for data systems up to 10 Mbit/s. Above that, edge loss from cable capacitance starts to matter and a higher-grade data cable is the better choice. Short-distance crosstalk attenuation of 50 dB minimum at 1 MHz and 40 dB minimum at 10 MHz defines how much the pairs interfere with each other in multi-pair constructions.

 

 

Hot Tags: unitronic li2ycy (tp) data cable, China unitronic li2ycy (tp) data cable suppliers

Common to All Three Variants - PE Insulation, Twisted Pairs, 100 Ohm

 

Parameter

Value

Core insulation

Polyethylene (PE)

Construction

Twisted pairs (TP)

Screen

Overall tinned-copper braid

Core identification

DIN 47100 colour code, see Appendix T9

ETIM 5.0/6.0

Class ID EC000104 - control cable

Mutual capacitance

800 Hz: max. 60 nF/km

Inductance

approx. 0.65 mH/km

Characteristic impedance

100 ± 15 Ohm (> 1 MHz)

Crosstalk attenuation

≤ 1 MHz min. 50 dB · ≤ 10 MHz min. 40 dB

Test voltage

Core/core 2000 V · Core/screen 1000 V

Min. bending radius - fixed

6 x O.D.

Min. bending radius - occasional flexing

15 x O.D.

Temperature - fixed

-40 °C to +80 °C

Temperature - occasional flexing

-5 °C to +70 °C

Flame retardancy

IEC 60332-1-2

Approval

VDE 0812

 

Variant Differences

 

Parameter

Li2YCY (TP)

Li2YCY (TP) fine-strand

Li2YCYv (TP)

Conductor construction

7-strand, VDE 0881

Multi-strand fine copper

7-strand, VDE 0881

Cross-sections

0.22 / 0.34 / 0.5 mm²

0.25 mm²

0.22 / 0.34 / 0.5 mm²

Pairs available

1 – 10

1 – 5

1 – 10

Sheath material

PVC

PVC

Reinforced PVC (Yv)

Sheath colour

Light grey RAL 7032

Light grey RAL 7032

Black RAL 9005

Nominal sheath wall

Standard

Standard

min. average 1.8 mm

 

Note: the reinforced "Yv" sheath is what allows Li2YCYv (TP) to be laid outdoors and direct-buried;

 

 

All figures nominal. Copper base EUR 150/100 kg. Packaging: coil up to 30 kg, drum above 30 kg. State packaging when ordering (e.g. 1 x 500 m drum or 5 x 100 m coil). AWG sizes are approximate conversions.

 

UNITRONIC Li2YCY (TP) — Part Number Table

 

Article No.

Pairs x Cross-sec. mm²

AWG

O.D. mm

Copper kg/km

Weight kg/km

0031320

2 x 2 x 0.22

24

6.5

24.2

59

0031321

3 x 2 x 0.22

24

7.1

28.6

66

0031322

4 x 2 x 0.22

24

7.3

34.2

78

0031323

8 x 2 x 0.22

24

9.1

70

125

0031324

10 x 2 x 0.22

24

10.4

76

143

0031335

1 x 2 x 0.34

22

5.8

20

44

0031325

2 x 2 x 0.34

22

7.7

34.1

79

0031326

3 x 2 x 0.34

22

8.4

43

89

Article No.

Pairs x Cross-sec. mm²

AWG

O.D. mm

Copper kg/km

Weight kg/km

0031327

4 x 2 x 0.34

22

8.7

47

101

0031328

8 x 2 x 0.34

22

11

85.8

176

0031336

1 x 2 x 0.5

20

6.3

29

53

0031330

2 x 2 x 0.5

20

8.5

37

85

0031331

3 x 2 x 0.5

20

9.3

55

105

0031332

4 x 2 x 0.5

20

9.6

60

122

0031333

8 x 2 x 0.5

20

12.7

113.3

213

0031334

10 x 2 x 0.5

20

14.8

154

261

 

UNITRONIC Li2YCY (TP) Fine-Strand Conductor — Part Number Table

 

Article No.

Pairs x Cross-sec. mm²

AWG

O.D. mm

Copper kg/km

Weight kg/km

0031370

1 x 2 x 0.25

24

5.7

14

38

0031371

2 x 2 x 0.25

24

6.9

28

43

Article No.

Pairs x Cross-sec. mm²

AWG

O.D. mm

Copper kg/km

Weight kg/km

0031372

3 x 2 x 0.25

24

7.5

39.6

64

0031373

5 x 2 x 0.25

24

8.3

50

93

 

UNITRONIC Li2YCYv (TP) — Part Number Table

 

Black, for outdoor installation and direct burial, 7-strand conductor.

 

Article No.

Pairs x Cross-sec. mm²

AWG

O.D. mm

Copper kg/km

Weight kg/km

0031350

2 x 2 x 0.22

24

8.1

24.2

79

0031351

3 x 2 x 0.22

24

8.7

28.6

93

0031352

4 x 2 x 0.22

24

8.9

34.2

100

0031353

8 x 2 x 0.22

24

10.7

70

156

0031354

10 x 2 x 0.22

24

12

76

185

0031365

1 x 2 x 0.34

22

7.4

20

69

0031355

2 x 2 x 0.34

22

9.3

34.1

102

0031356

3 x 2 x 0.34

22

10

43

117

Article No.

Pairs x Cross-sec. mm²

AWG

O.D. mm

Copper kg/km

Weight kg/km

0031357

4 x 2 x 0.34

22

10.3

52.8

130

0031358

8 x 2 x 0.34

22

12.6

85.8

206

0031366

1 x 2 x 0.5

20

7.9

29

79

0031360

2 x 2 x 0.5

20

10.1

37

120

0031361

3 x 2 x 0.5

20

10.9

55

142

0031362

4 x 2 x 0.5

20

11.2

60

160

0031363

8 x 2 x 0.5

20

13.9

113.3

251

0031364

10 x 2 x 0.5

20

16

148

303

 

Send Inquiry