UNITRONIC LiHH Data Cable

UNITRONIC LiHH Data Cable
Details:
UNITRONIC LiHH flexible halogen-free (LSZH) data transmission cable: DIN 47100 color code, VDE 0812 compliant, IEC 60754-1/2 zero corrosive gas, compact unshielded profile for public transit and building automation.

Standards & Compliance
VDE 0812 | DIN 47100 Color Code | IEC 60754-1 (Zero Halogen) | IEC 60754-2 | IEC 61034-2 | EN 50305 Toxic Index | IEC 60332-1-2 Flame Retardant

Quick Specs
1200 V AC test | 0.14 – 1.0 mm² (2–12 cores) | −30 °C to +80 °C fixed | DIN 47100 cores, unshielded LSZH, compact 4.0 mm minimum OD
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of unitronic lihh data cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

UNITRONIC LiHH is the unshielded halogen-free data cable for public transit, high-rise and automated buildings. Its polyolefin compounds remove the chlorinated chemistry of PVC: IEC 60754-1 confirms zero halogen gas, IEC 60754-2 keeps combustion gases at pH 4.3 or above with conductivity ≤ 10 µS/mm, and IEC 61034-2 holds light transmittance at 60% or better, so evacuation routes stay breathable and visible. Leaving out the metallic braid keeps the cable compact - 2-core 0.25 mm² measures just 4.0 mm across - which raises packing density inside crowded cabinet ducting. KABASI ships UNITRONIC LiHH reels and pre-terminated sensor harnesses on expedited factory dispatch.

 

Select Your Variant

 

Family Architecture Comparison: LiHH vs. LiHCH vs. LiHCH (TP)

Engineering Selection Criterion

UNITRONIC LiHH (Unshielded)

UNITRONIC LiHCH (Braid Screened)

UNITRONIC LiHCH (TP) (Twisted Pair Screened)

Internal Structural Profile

Cores stranded in concentric layers, unshielded

Concentric layer cores enclosed in tinned copper wire braid

Cores twisted into individual pairs (TP) with overall copper braid

Electromagnetic Interference (EMI)

Standard noise immunity (for metal ducts or quiet environments)

Effective high-frequency shielding against external radiated noise

Dual protection: TP cancels internal channel crosstalk, braid blocks external EMI

Space Footprint & Bend Flexibility

Smallest outer diameter; tightest bending radius (10 × OD flex)

Moderate diameter increase due to braid; 10 × OD flex

Larger diameter due to pair twist lay length; 15 × OD flex

Typical Target Signals

Discrete digital I/O, limit switches, relay logic, pushbuttons

Single-ended analog loops (4–20 mA), encoder data, display busses

Differential RS422/RS485 data, high-rate serial links, instrumentation pairs

 

Typical Applications

 

01stainless-steel-control-console-two-analogue-meters-indicator-lamps-selector-switches-and-a-red-emergency-stop-on-a-brushed-enclosure

Transport Systems - Metro Stations and Passenger Terminals
A metro station panel collects its supervisory channels from smoke dampers and evacuation consoles along the tunnel behind it, which is why the sheath is LSZH: no halogen acid gas, low smoke density to IEC 61034-2.

02electronics-rack-with-plug-in-boards-ribbon-cables-and-idc-connectors-linking-processor-and-i-o-cards-inside-an-open-chassis

Public Buildings - Access Control and Building Services
Access control runs leave the riser and enter card readers and door actuators in the dry or occasionally damp interior this cable is rated for, where a four-core 0.25 mm² cable is still only 4.5 mm across..

03air-handling-unit-fan-section-heat-exchanger-coil-and-filter-frame-inside-a-galvanised-casing-with-the-access-panels-open

Factory Floor - Air Handling Telemetry
 
Fan filter unit tachometer and temperature readings travel back to the controller through a ceiling plenum full of drives, and the polyolefin insulation holds mutual capacitance at about 80 nF/km so the reading arrives as it left.

04checkweigher-on-a-stainless-frame-conveyor-belt-hmi-display-showing-the-weight-and-a-stack-light-at-the-discharge-end

Measurement & Control - Weighing and Packaging Lines
Scale indicators and conveyor sensors land in one terminal block, where the DIN 47100 colours without repetition let seven and four cores be terminated without tracing continuity.

 

Why Choose UNITRONIC LiHH Series

 

Advantage

What it means on site

True Zero-Halogen Formulation Guarantees Life Safety and Electronic Asset Protection

Releases no corrosive hydrogen chloride gas during combustion, protecting human evacuation routes and preventing multi-million-dollar server, PLC, and relay bank destruction.

Ultra-Compact Outer Diameter Maximizes Raceway Packing Density

Unshielded construction eliminates bulky braid layers, yielding diameters down to 4.0 mm that slip easily through overcrowded building conduits and miniaturized instrument enclosures.

Standardized DIN 47100 Color-Coded Cores Ensure Error-Free Wire Termination

Features distinct, non-repeating color hues across all cores up to 12 conductors, speeding up termination labor and eliminating wire-tracing continuity testing.

Polyolefin-Based Dielectric Insulation Delivers Low 80 nF/km Capacitance

Maintains clean digital square-wave pulses and prevents signal attenuation across extended cable runs in building automation and sensor networks.

 

Life-Safety Halogen-Free Combustion Mechanism

 

In modern closed or high-occupancy buildings, cable fire safety is measured not merely by flame resistance, but by toxic combustion byproducts and optical smoke obscuration. UNITRONIC LiHH engineered polyolefins fundamentally shift the fire behavior profile:

 

Combustion Test Criterion

International Test Standard

UNITRONIC LiHH (LSZH) 

Halogen Acid Gas Evolution

IEC 60754-1

Zero halogens (< 5 mg/g HCl); completely chlorine, fluorine, and bromine free.

Combustion Gas Acidity & pH

IEC 60754-2

pH value ≥ 4.3 and conductivity ≤ 10 µS/mm; non-corrosive, preventing server and PLC hardware destruction.

Smoke Density & Optical Visibility

IEC 61034-2

Light transmittance ≥ 60%; clear optical visibility maintained for emergency exit signs and firefighting.

Toxicity Index of Gases

EN 50305 

Low toxicity index; safe for human respiration in underground tunnels and confined train stations.

 

Specifying UNITRONIC LiHH meets the low-smoke zero-halogen fire-safety requirements of public buildings and transit systems without compromising electrical signal integrity.

 

Frequently Asked Questions

 

Q: What does the abbreviation "LiHH" stand for in cable nomenclature?

A: In European VDE cable designation codes: "Li" indicates stranded fine-wire flexible copper conductors; the first "H" denotes a halogen-free thermoplastic core insulation (polyolefin compound); and the second "H" indicates a halogen-free thermoplastic outer sheath (LSZH compound). It designates a fully zero-halogen, unshielded multi-core flexible data cable.

Q: Why is halogen-free cable mandatory in public buildings and transit tunnels?

A: Conventional PVC cables contain chlorine that generates toxic, suffocating hydrogen chloride gas when burning, forming hydrochloric acid in human lungs and corroding building steel and electronics. Halogen-free cables like LiHH emit virtually zero acid gas (IEC 60754-1/2) and low smoke (IEC 61034-2), preserving breathable air and clear vision for passenger evacuation.

Q: When should I choose unshielded LiHH instead of screened LiHCH?

A: Choose unshielded LiHH when cables run inside grounded metallic conduit or wireways where external electromagnetic noise is already shielded, or for simple low-speed discrete switching circuits. LiHH offers a smaller outer diameter, lower cost, faster stripping, and tighter bending radii than braided LiHCH.

Q: Can UNITRONIC LiHH be used for 230V or 400V power supply?

A: No. UNITRONIC LiHH is strictly rated as a low-frequency data, signal, and instrumentation cable. It is not approved or insulated for mains power distribution. For halogen-free power circuits, specify OLFLEX CLASSIC 110 H or OLFLEX CLASSIC 130 H.

Q: What core color identification standard does UNITRONIC LiHH follow?

A: UNITRONIC LiHH follows the standardized DIN 47100 color code without color repetition. Each core has a distinct, solid or striped color identity , ensuring rapid and error-free pinout termination without relying on printed numbers.

 

 

Hot Tags: unitronic lihh data cable, China unitronic lihh data cable suppliers

Electrical, Mechanical & Fire Safety Standards

 

Technical Parameter

Standard reference / value

Conductor Stranding

Fine multi-strand bare copper; 0.34 mm² is 7 strands (VDE 0812)

Core Insulation

Special halogen-free polyolefin compound

Core Identification

DIN 47100 standard color code without color repetition (see catalogue appendix T9)

Outer Sheath Material

Special halogen-free flame-retardant compound (LSZH), pebble grey (similar to RAL 7032)

Dielectric Test Voltage

1200 V AC

Mutual Capacitance

Approx. 80 nF/km

Inductance

Approx. 0.65 mH/km

Minimum Bending Radius

Occasional flexing: 10 × outer diameter | Fixed installation: 6 × outer diameter

Temperature Range (Flexing)

−5 °C to +70 °C

Temperature Range (Fixed)

−30 °C to +80 °C

Halogen Acid Gas Emission

IEC 60754-1 - halogen-free

Corrosiveness of Combustion Gases

IEC 60754-2 - low corrosivity and acidity of combustion gases

Smoke Density & Visibility

IEC 61034-2 - low smoke density

Toxicity of Combustion Fumes

EN 50305 low toxicity index compliance

Flame Retardance

IEC 60332-1-2 single-cable vertical flame propagation test

 

Unshielded Cable Routing & Conduit Segregation Guidelines in Public Buildings

 

Because UNITRONIC LiHH is an unshielded cable design, optimal noise immunity is achieved through correct physical conduit management and spatial separation:

 

Installation Constraint

Recommended Engineering Practice

Physical Separation Guideline

Failure Risk Avoided

Separation from Power Circuits

Route LiHH in dedicated metal cable trays or separate metallic compartments

Maintain minimum 50 mm clearance from 400V power lines (or solid metal barrier)

Prevents 50 Hz electromagnetic coupling and inductive switching surges onto signal cores.

Raceway Fill Ratio

Limit wire trough cross-sectional fill to 40% maximum capacity

Calculated based on compact outer diameter table in section 8.2

Prevents jacket crushing and localized hot spots while preserving cable pulling flexibility.

Strain Relief & Gland Entry

Use polyamide or brass cable glands with elastomer grommets

Select gland clamping range matching exact cable OD (4.0 mm to 10.4 mm)

Preserves IP65/IP68 enclosure sealing and prevents sheath cold-flow migration under clamping.

Earthing & Bonding Practice

Ensure all metallic raceways, ducts, and junction boxes are bonded to equipotential earth

Bonding impedance < 0.1 Ω across all conduit joints

Converts enclosing steel conduit into an effective external Faraday shield for the unshielded cores.

 

Metric to AWG Reference Notice

 

UNITRONIC LiHH is manufactured to metric cross-sections with equivalent AWG ratings recognized for international engineering reference.

 

Metric Section (mm²)

Equivalent North American AWG Designation

0.14

26

0.25

24

0.34

22

0.5

20

0.75

18

1.0

17

 

UNITRONIC LiHH — Part Number Directory

 

Halogen-free unshielded flexible data cable with DIN 47100 color code. Selected catalogue listing from 0037104 to 0037172 with integrated AWG equivalents.

 

Part No.

Cores × mm²

Equivalent AWG

Outer Diameter (mm)

Copper Index (kg/km)

Total Weight (kg/km)

0037104

6 x 0.14

26 AWG

4.4

8.1

25

0037120

2 x 0.25

24 AWG

4.0

4.8

22

0037121

3 x 0.25

24 AWG

4.2

7.2

25

0037122

4 x 0.25

24 AWG

4.5

9.6

28

0037125

7 x 0.25

24 AWG

5.3

16.8

42

0037126

8 x 0.25

24 AWG

6.4

19.2

50

0037128

12 x 0.25

24 AWG

7.2

28.8

67

0037140

2 x 0.34

22 AWG

4.4

6.5

28

0037141

3 x 0.34

22 AWG

4.6

9.8

30

0037142

4 x 0.34

22 AWG

5.0

13.1

40

Part No.

Cores × mm²

Equivalent AWG

Outer Diameter (mm)

Copper Index (kg/km)

Total Weight (kg/km)

0037147

12 x 0.34

22 AWG

8.0

39.2

97

0037150

2 x 0.5

20 AWG

4.9

9.6

31

0037151

3 x 0.5

20 AWG

5.2

14.4

37

0037152

4 x 0.5

20 AWG

5.8

19.2

45

0037154

7 x 0.5

20 AWG

7.1

33.6

72

0037160

2 x 0.75

18 AWG

5.3

14.4

41

0037162

4 x 0.75

18 AWG

6.3

28.8

60

0037165

12 x 0.75

18 AWG

10.4

86.4

165

0037171

3 x 1.0

17 AWG

6.1

28.8

57

0037172

4 x 1.0

17 AWG

6.6

38.4

67

 

Send Inquiry