HELUKABEL LiYv Single Core Hook-Up Wire

HELUKABEL LiYv Single Core Hook-Up Wire
Details:
Tinned-copper PVC single-core hook-up wire to DIN VDE 0812 — class 5 stranding, 0.14 to 1.5 mm², sixteen colours, 500 / 900 V peak.
Standards & Compliance
DIN VDE 0812 hook-up wire | DIN VDE 0295 cl. 5 tinned | IEC 60332-1-2 | CE 2014/35/EU

Quick Specs
Peak 500 / 900 V | Tinned copper Class 5 | −5 to +70 °C mobile · −30 to +80 °C fixed | 1200 / 2500 V test | 0.14–1.5 mm² single-core
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of helukabel liyv single core hook-up wire in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Positioning of the Hook-Up Wire Range

 

LiYv is a PVC single-core hook-up wire with a tinned copper conductor, fine-stranded to DIN VDE 0295 class 5 (BS 6360 class 5, IEC 60228 class 5) and built to DIN VDE 0812. The tin layer does the two jobs this wire is asked to do inside equipment: it keeps the strand face from oxidising in damp air, and it wets quickly when the joint is soldered instead of crimped.

 

Six cross-sections run from 0.14 to 1.5 mm². Insulation is special PVC YI3 to DIN VDE 0812, self-extinguishing and flame-retardant to DIN VDE 0482-332-1-2, DIN EN 60332-1-2 and IEC 60332-1, and the fixed bending radius is 4 x core Ø - which is what lets the wire turn inside a shallow duct without springing back out of the corner.

 

It connects low-voltage equipment, telecom gear, electronic assemblies, racks and distribution boards, within the +70 °C condition that VDE 0800 part 1 sets for that duty. Sixteen colour options - thirteen of them RAL-numbered, plus transparent, other-colour and two-colour - are supplied on 100 m plastic spools.

 

Conductor Size, Colour Range and Supply Format

 

LiYv provides 6 standardized conductor cross-sections matched to specific electronic assembly and cabinet functions:

 

Cross-section

Outer diameter

Copper weight

Peak voltage

Test voltage

0.14 mm2

1.1 mm

1.4 kg/km

500 V

1200 V

0.25 mm2

1.3 mm

2.4 kg/km

900 V

2500 V

0.50 mm2

1.8 mm

4.8 kg/km

900 V

2500 V

0.75 mm2

2.0 mm

7.2 kg/km

900 V

2500 V

1.00 mm2

2.1 mm

9.6 kg/km

900 V

2500 V

1.50 mm2

2.6 mm

14.4 kg/km

900 V

2500 V

 

Sixteen colour options per cross-section. Each has one article number, so the colour is chosen by part number rather than by a note on the order - the two-colour build is the one exception, where base and ring colour are stated alongside it.

 

Colour Colour reference
Black RAL 9005
Green-yellow RAL 6018
Blue RAL 5015
Brown RAL 8003
Red RAL 3000
White RAL 9003
Grey RAL 7000
Violet RAL 4005
Yellow RAL 1021
Pink RAL 3015
Green RAL 6018
Transparent -
Dark blue RAL 5010
Orange RAL 2003
Other colour to be agreed at order
Two-colour base colour + ring colour

 

Stripping, Crimp and Routing Guide

 

Four things decide whether a class 5 hook-up wire survives in a panel: how the tin layer is treated at the crimp, how the blade is set, how tightly the wire is bent, and how it is paid off the reel.

 

The tin layer at the crimp

A tinned strand bundles into a ferrule without the surface oxide that makes bare copper slip under the crimper, and the joint keeps its resistance where the panel breathes damp air. Solder joints take the same benefit: the tin wets at low temperature, so the flux does not have to be aggressive.

01

Cutting a fine-strand wire

Fine strands cut clean on a standard strip blade; the failure mode is nicking, not fraying. Set the blade depth against the insulation wall rather than against the conductor, and check the first cut of every new reel.

 

02

Holding the 4 x core Ø bend

Fixed installation is rated at 4 x core Ø. That is the number to hold where the wire turns out of a duct and into a terminal; a tighter corner work-hardens the strands at exactly the point that has to stay flexible.

03

Payoff and pack size

Standard supply is a 100 m plastic spool, which covers bench work and field repair from the same reel. Other capacities are quoted per order.

04

 

Typical Applications

 

01low-voltage-switchgear-secondary-wiring-terminal-blocks-contactors-and-multicoloured-control-cores-wired-point-to-point-inside-the-panel

Low-voltage switchgear and distribution panel secondary wiring
Point-to-point control wiring inside the panel; thirteen of the sixteen colours are locked to a RAL number, so the reel matches the drawing.

02industrial-machine-tool-push-button-control-boxes-two-grey-enclosures-with-emergency-stop-selector-switch-and-indicator-lamps-inside

Industrial machine tool local operator and push-button control boxes
Emergency-stop stations, tower lamps and foot switches, folded behind a shallow front plate on a 4 x core Ø bend.

03industrial-luminaire-linear-led-batten-with-the-diffuser-open-showing-the-driver-terminal-block-and-green-yellow-protective-lead-inside-the-housing

Industrial luminaire and lighting circuit conduit installation
Protective lead inside enclosed luminaires and lighting trunking, self-extinguishing to IEC 60332-1.

04automated-wire-harness-assembly-cell-reel-of-cable-feeding-a-cut-strip-crimp-press-with-copper-lugs-laid-out-on-the-bench

Automated wire harness subcontract high-speed assembly cells
100 m spools feed a cut-strip-crimp cell; class 5 copper crimps without stray strands outside the ferrule.

 

Why Specify LiYv

 

Why electrical design engineers and contract wire harness manufacturers standardize on LiYv for internal enclosure wiring:

 

LiYv property

Harness-shop benefit

Tinned copper conductor The strand face resists oxidation in damp air, so a crimp or a solder joint does not build resistance over the life of the panel.
Class 5 stranding to DIN VDE 0295 Fine strands take a 4 x core Ø fixed bend and a ferrule crimp without the spring-back a solid core gives you.
Sixteen colour options, thirteen RAL-numbered Sixteen colour options, thirteen RAL-numbered
Special PVC YI3 to DIN VDE 0812 Thin-wall insulation that still carries the flame and dielectric duties of the standard, so more conductors fit the same duct.
100 m plastic spool as standard

One pack size covers bench assembly and field repair, and the spool pays off on a rack without a decoiler.

DIN VDE 0812 construction, LVD 2014/35/EU The two documents a European drawing names, so the wire matches what the drawing calls for.

 

Frequently Asked Questions

 

Q: How does LiYv differ from H05V-K and H07V-K?

A: H05V-K is the 300/500 V PVC panel wire in 0.5, 0.75 and 1.0 mm², and H07V-K is the 450/750 V version running from 1.5 up to 240 mm²; both use bare copper. LiYv is a DIN VDE 0812 hook-up wire with a tinned conductor, and it goes down to 0.14 mm² - the size a relay rack or a PCB header actually needs.

Q: Why is LiYv restricted to internal wiring?

A: The range is specified for connecting equipment, racks and distribution boards, and high-current service outside equipment is excluded. A run that leaves the enclosure and carries load current is a different product with a different sheath and a different standard.

Q:What does the tin coating actually do?

A: Bare copper forms an oxide film in damp air, and that film is what raises contact resistance at a crimp. Tin passivates the strand surface, so the wire stays solderable without an aggressive flux and the crimp barrel does not corrode from the inside out.

Q: How is a two-colour wire ordered?

A: A two-colour wire is a base colour with a ring colour, and each cross-section has one article number for it. Quote the base and the ring colour in the order notes - the article number fixes the cross-section and the fact that it is two-colour, not which pair.

Q: What lengths are supplied?

A: Standard supply is 100 m per plastic spool, which is the pack size the range is stocked in. Other capacities are quoted per order.

Q: Are 500 V and 900 V AC working voltages?

A: No. They are peak working voltages - 500 V for 0.14 mm² and 900 V for 0.25 to 1.5 mm² - set against test voltages of 1200 V and 2500 V. Treat them as dielectric headroom for the 24 V DC and 230 V AC control circuits these wires usually serve, not as a continuous AC rating.

 

Hot Tags: helukabel liyv single core hook-up wire, China helukabel liyv single core hook-up wire suppliers

Baseline Electrical & Thermal Data

 

Peak operating voltage

Test voltage Temperature, moving Temperature, fixed

Conductor sizes

500 V (0.14 mm²) 

900 V (0.25 – 1.5 mm²)

1200 V (0.14 mm²)

2500 V (0.25 – 1.5 mm²)

−5 °C to +70 °C −30 °C to +80 °C

0.14 – 1.5 mm² (Single-core)

 

Hook-Up Wire Electrical & Mechanical Data

 

Electrical & mechanical baseline parameters

 

Parameter

Standard specification

Regulatory standards

DIN VDE 0812 (PVC single-core wires); VDE 0800 part 1 for the +70 °C condition
Conductor Tinned copper, fine-stranded to DIN VDE 0295 class 5, BS 6360 class 5, IEC 60228 class 5
Insulation Special PVC YI3 to DIN VDE 0812
Core identification By colour, see the colour table above
Peak working voltage 0.14 mm² at 500 V; 0.25 to 1.5 mm² at 900 V
Test voltage 0.14 mm² at 1200 V; 0.25 to 1.5 mm² at 2500 V
Insulation resistance Minimum 10 MOhm x km
Min. bending radius, fixed 4 x core Ø
Radiation resistance Up to 80 x 10⁶ cJ/kg (80 Mrad)
Flame retardancy DIN VDE 0482-332-1-2, DIN EN 60332-1-2 and IEC 60332-1 (equivalent to DIN VDE 0472 part 804, test method B)
Materials Free from cadmium and silicone; no paint-wetting impairment substances
Two-colour build Base colour plus ring colour
Supply format 100 m plastic spool as standard
Directive Low Voltage Directive 2014/35/EU

 

Hook-Up Wire Standards Basis

 

DIN VDE 0295 class 5 · IEC 60228 class 5 | DIN VDE 0812 single-core equipment wire | VDE 0800 part 1 (+70 °C condition) | IEC 60332-1 / DIN EN 60332-1-2 | Low Voltage Directive 2014/35/EU

Filtering Sizes, Colours and Supply Format

 

Part-number filtering — filter by conductor size across 13 RAL colours, plus the other-colour and two-colour ranges, then switch between the 100 m spool and the barrel supply tables.

 

LiYv Part-Number Schedule by Supply Format

 

Complete cross-reference schedule of all 176 LiYv part numbers across 6 conductor sizes and 16 color combinations, covering standard 100m spools and bulk barrels: