Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of trvu highly-flex drag chain cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Lead Paragraph
The highly-flex drag chain cable is the higher duty step of the flexible drag chain range, built for continuous-flex duty in cable carriers where the travel is longer and the acceleration higher. All three series share one construction: an ultra-fine tinned copper stranded conductor, special elastomer insulation and a special TPU polyether compound outer sheath, with the cores carried in anti-twist layers or group gap filling and the conductor stranding meeting the requirement for highly flexible cables. The three differ in the screen - TRVU carries none, TRVUP adds a tinned copper braided screen outside the insulation, and TRVUSP twists the pair inside that screen. On duty, travel acceleration is 30 m/s² and bending life exceeds 12 million cycles at a cycle rate of 88 cycles/min/m, service temperature is −30 °C to +80 °C, and abrasion resistance is higher than on the moderate grade.
Selection: Three Screen Variants
At a glance: the three series share conductor, insulation, jacket, cord structure, rated voltage, bending radius, service temperature and travel characteristics; choosing a series means choosing the screen, and whether the core identification step is wide enough
2.1 By On-Site Interference and Signal Type
- TRVU: no screen, so the jacket encloses three layers only - conductor, insulation and jacket - for drag chain runs with no strong interference source.
- TRVUP: a tinned copper braided screen that strengthens interference rejection, for locations that need screening.
- TRVUSP: the pair twisted plus a tinned copper braided screen, with the twisting inside the screen, for circuits that need screening and carry signals.
| Requirement | Recommended Series | Basis |
| Power or ordinary control circuits with no strong interference source | All | Conductor, insulation, outer sheath and every electrical figure are shared across the three series, so this duty needs no extra screen |
| Drag chain runs that need screening | TRVUP | The tinned copper braided screen strengthens interference rejection and resists electromagnetic interference well |
| VFDs and servo drives running alongside signal lines | TRVUP | The braid closes over the cable against external fields, and the screen itself does not sit between the pairs |
| Encoder, bus and analogue circuits sensitive to crosstalk | TRVUSP | The twisting sits inside the screen and couples the pairs still less, for more stable signal transmission |
2.2 How the Conductor Count Is Expressed
- TRVU and TRVUP are counted in single cores.
- TRVUSP is counted in pairs and is specified as 2P and 3P.
Typical Applications
The duty is one - continuous reciprocating motion inside a cable carrier, in industrial environments where bending is frequent. What changes is the equipment the cable runs in.




Why Choose the Highly-Flex Drag Chain Cable
30 m/s² travel acceleration and >12 million cycles, faster and more wear-resistant than the moderate grade.
Bending life exceeds 12 million cycles at 88 cycles/min/m on a travel acceleration of 30 m/s²; the moderate drag chain cable runs 20 m/s² and >7 million cycles. Both are duty steps of the same construction.
A special TPU polyether compound outer sheath over special elastomer insulation.
The outer sheath is a special TPU polyether compound: durable, resistant to UV, weathering, cold and oil, and able to take heavier mechanical stress; the conductor is ultra-fine tinned copper, finely stranded, with the stranding to the requirement for highly flexible cables.
Conductor stranding to highly flexible requirements, cores in anti-twist layers.
The conductor stranding meets the requirement for highly flexible cables, and the cores are laid up in anti-twist layers or group gap filling, which holds the lay stable in reciprocating motion.
Three screen variants, with the twisting inside the screen.
TRVUP carries a tinned copper braided screen that strengthens interference rejection; TRVUSP twists the pair inside that screen for stable signal transmission characteristics, covering interference and crosstalk together.
Frequently Asked Questions
Q: How do the three series differ?
A: In three product respects: the screen, the core identification code, and whether the core count is expressed in cores or in pairs. TRVU carries no screen; TRVUP adds a tinned copper braided screen; TRVUSP twists the pair inside that screen. On identification, TRVU and TRVUP use insulation colour up to 5 cores and white numbers above 5, while TRVUSP widens that to 10 cores by insulation colour and white numbers above 10.
Q: How does this grade divide the work with the moderate drag chain cable?
A: By duty step. The moderate grade runs a 20 m/s² travel acceleration and >7 million cycles of bending life; this one runs 30 m/s² and >12 million cycles at 88 cycles/min/m, with higher abrasion resistance, an ultra-fine tinned copper stranded conductor, a special TPU polyether compound outer sheath and a service temperature ceiling of +80 °C. Take this grade where the travel is longer, the acceleration higher and the duty is continuous flexing inside a cable carrier.
Q: How many screen designs are there?
A: Three, matching the three series: no screen, a tinned copper braided screen against interference, and a twisted pair plus tinned copper braided screen. The last puts the twisting inside the screen, covering anti-interference and anti-crosstalk together for more stable signal transmission.
Q: What are the core identification and the supply form?
A: Identification is as in 6.1, and can also be made to a specified requirement. On supply form, TRVU and TRVUP are counted in single cores and TRVUSP in pairs, specified as 2P and 3P. Colours and materials can be made to customer requirement.
Q: What are the bending life and the acceleration?
A: Bending life exceeds 12 million cycles at 88 cycles/min/m on a travel acceleration of 30 m/s², identical across the three series.
Q: Which standards and approvals apply?
A: As printed on each item: the reference standards are UL758, TÜV and enterprise standards for TRVU and TRVUP, and UL758 and enterprise standards for TRVUSP. The cable is available to UL - E531888-UL-758-1 for TRVU and TRVUP, E531888-UL-758 for TRVUSP - and to CCC 5023&8734, and flame retardancy passes GB/T 18380 and meets VW-1; all of these are optional.
Q: What characterises the conductor stranding and the cord structure?
A: The conductor is ultra-fine tinned copper stranded, with the stranding to the requirement for highly flexible cables; the cores are laid up in anti-twist layers or group gap filling, which holds the lay stable in successive reciprocating motion.
Requesting the Highly-Flex Drag Chain Cable
On the enquiry, state the series (TRVU / TRVUP / TRVUSP), the core count or pair count × cross-section, the installation (fixed or moving), the drag chain travel and acceleration, the maximum service temperature and the approval you need (UL or CCC); for TRVUSP, say whether it is 2P or 3P. For a finished assembly, give the termination at each end as well.
.
Hot Tags: trvu highly-flex drag chain cable, China trvu highly-flex drag chain cable suppliers
Specifications Common to the Three Series
| Parameter |
Rating |
| Rated voltage U0/U by cross-section | ≤0.5 mm²: 300/300 V; >0.5 mm²: 300/500 V |
| Conductor | Ultra-fine tinned copper, finely stranded |
| Conductor stranding | To the requirement for highly flexible cables; conformity to UL, CCC and TÜV standards available as an option |
| Insulation | Special elastomer compound |
| Outer sheath | Special TPU polyether compound |
| Cord structure and lay-up | Anti-twist layering, or group gap filling |
| Minimum bending radius | 5 × OD fixed; 8 × OD moving |
| Service temperature | −30 °C to +80 °C |
| Bending cycles and operation parameters | 30 m/s² travel acceleration; bending life >12 million cycles at 88 cycles/min/m |
| Flame retardancy | Flame retardant to GB/T 18380; VW-1 (optional) |
| Chemical resistance | Oil, cold and UV resistance on all three series; see the series comparison for shallow-water, abrasion and solvent resistance |
| Features | Oil, cold and UV resistance; abrasion resistance higher than the moderate grade; takes heavier mechanical stress |
| Reference standards | UL758, TÜV, enterprise standards (TRVU / TRVUP); UL758, enterprise standards (TRVUSP) |
| Certification | UL E531888-UL-758-1 (TRVU / TRVUP), E531888-UL-758 (TRVUSP); CCC 5023&8734 |
| Options | Core and outer sheath colour and material |
Item-by-Item Comparison Across the Three Series
A row split by series gives the value for each of the three; a row merged across the columns is the same on all three. Reference standards and certification numbers are listed per series - take the column for the series you are specifying.
| Parameter | TRVU | TRVUP | TRVUSP |
| Series | Unshielded drag chain cable | Shielded drag chain cable | Pair-twisted shielded drag chain cable |
| Braiding | None | Tinned copper braided shielding against | Twisted pair + tinned copper braided shielding |
| Core count expressed as | Single cores | Pairs, specified as 2P and 3P | |
| Core identification code | ≤5 cores by insulation colour; >5 by white numbers; or to a specified requirement | ≤10 cores by insulation colour; >10 by white numbers; or to a specified requirement | |
| Application | Indoor and outdoor | Indoor and outdoor locations that need screening | |
| Rated voltage U0/U | ≤0.5 mm²: 300/300 V; >0.5 mm²: 300/500 V | ||
| Minimum bending radius | 5D fixed; 8D moving | ||
| Service temperature | −30 °C to +80 °C | ||
| Chemical resistance | Oil, cold and UV resistance | Shallow-water, oil, UV, cold and abrasion resistance | Oil, cold and acid, alkali and solvent resistance |
| Bending cycles and operation parameters | 30 m/s² acceleration; bending life >12 million cycles at 88 cycles/min/m | ||
| Conductor / insulation / outer sheath | Ultra-fine tinned copper, finely stranded / special elastomer insulation / special TPU polyether compound sheath | ||
| Cord structure and lay-up | Anti-twist layering, or group gap filling | ||
| O.D. approx. | 4.0 to 6.0 mm, tolerance ±0.4 mm | 4.6 to 6.8 mm, tolerance ±0.4 mm | 5.8 to 9.7 mm, tolerance ±0.4 / ±0.6 mm |
| Weight approx. | 19.0 to 50.8 kg/km | 27.1 to 64.2 kg/km | 41.5 to 169.0 kg/km |
| EMC behaviour | - | Good resistance to electromagnetic interference (braided screen) | Stable signal transmission, interference and crosstalk (twisted pair + braided screen) |
| Flame retardancy | Flame retardant to GB/T 18380; VW-1 (optional) | ||
| Chemical resistance | Excellent oil, cold and acid and alkali solvent resistance | ||
| Features | Waterproofing, oil resistance, UV resistance, cold resistance and abrasion resistance; takes heavier mechanical stress | ||
| Reference standards | UL758, TÜV, enterprise standards | UL758, enterprise standards | |
| Certification | UL E531888-UL-758-1; CCC 5023&8734 | UL758, enterprise standards | |
| Options | Core and outer sheath colour and material | ||