Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of sensorflex sensor cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Positioning of the Sensor Cable Range
SENSORFLEX is a sensor and actuator cable for decentralised installation and control technology. It connects sensors and actuators through pluggable circular connectors and integrated actuator-sensor boxes, and forms the link between the field devices on a machine and the PLC in the cabinet. Moving the I/O point out to the machine periphery is what the construction is shaped for: the wiring that used to run back to the cabinet is replaced by a trunk.
Three sheath builds sit under one type. All three use bare copper conductors with PVC core insulation and identify cores by colour: the PVC build is class 5 or 6 fine or extra-fine wire with a special PVC outer sheath; the PUR build is class 6 extra-fine wire with a PUR sheath; the PVC/PUR build keeps the PVC structure and adds a PVC inner sheath under a co-extruded PUR outer sheath.
The voltage steps once, at the cross-section: up to 0.25 mm² the peak working voltage is 350 V against a 1200 V AC test at 50 Hz, and from 0.34 mm² upward it is 500 V against 2000 V. Minimum bending radius is 15 x cable OD on the PVC build and 7.5 x on PUR and PVC/PUR. Yellow on the PUR build is RAL 1021 to DESINA and every build carries yellow as its third article number. UL/CSA approval and copper screening are available across the range, quoted per order.
Selecting Sheath Material for Sensor Duty
The three builds differ in sheath compound and conductor class, not in core count or colour sequence.
Sheath material & conductor comparison
|
Variant |
Conductor |
Sheath material |
Bend radius (dynamic) |
What the build is specified for |
|
SENSORFLEX PVC |
Bare copper, DIN VDE 0295 class 5 or 6 | Special PVC |
15 x cable OD |
Oil and chemical resistance with a self-extinguishing PVC sheath |
|
SENSORFLEX PUR |
Bare copper, DIN VDE 0295 class 6, extra-fine | PUR |
7.5 x cable OD |
Low adhesion, high abrasion resistance, resistant to hydrolysis and microbial attack; class 6 stranding for drag-chain duty |
|
SENSORFLEX PVC/PUR |
As SENSORFLEX PVC | PVC inner sheath, co-extruded PUR outer sheath |
7.5 x cable OD |
The PVC structure with a PUR outer skin, in yellow RAL 1021 to DESINA |
Sheath Diameter, Core Colours and Drag-Chain Entry
Four things decide whether a sensor lead survives at the machine: the sheath diameter the gland has to take, the core colours read at the terminal, the bending radius held at the entry, and how the cable is clamped where it enters a drag chain.
Sheath diameter per build
Outside diameter runs from 4.4 mm on 3 x 0.25 mm² to 5.9 mm on the 5 x 0.34 mm² builds. Core count does not fix the diameter on its own - 3 x 0.25 mm² is 4.4 mm in both PVC and PUR, while 5 x 0.34 mm² PVC and 5 G 0.34 mm² PVC/PUR are both 5.9 mm - so the gland is sized from the article number.
01
Core colours per build
Core colours follow the build, not a single house code. The 3-core builds are brown, blue, black, except 3 G 0.34 mm² PVC/PUR, which is brown, blue, green-yellow. Four cores add white. The 5 x 0.34 mm² PVC build closes with grey, and the 5 G builds close with green-yellow. Read the colour list against the article number.
02
Bending radius at the entry
PVC is 15 x cable OD; PUR and PVC/PUR are 7.5 x. The figure is the installed minimum the construction is specified to, and it is the number to hold where the cable leaves a duct or turns into a connector body.
03
Drag-chain entry
The class 6 extra-fine stranding is what the PUR build is specified with for drag-chain use, and the low-adhesion sheath is what keeps it from fusing to the cable running beside it. The PVC build is the 15 x cable OD construction and is not the drag-chain variant.
04
Typical Applications




Why Specify SENSORFLEX
|
SENSORFLEX strength |
Field effect |
| 4.4 – 5.9 mm outer diameter, 22 – 54 kg/km | A compact sensor lead that adds little mass to a moving axis and fits a small gland without a reducer. |
| Class 6 extra-fine strands on the PUR build | The construction the drag-chain variant is specified with; the PVC build is class 5 or 6. |
| Yellow sheath to RAL 1021 under DESINA | One colour reserved for sensor and actuator circuits on a machine tool, so a 24 V signal run is identifiable without a label. |
| PVC/PUR composite sheath | A PVC inner sheath under a co-extruded PUR outer: PUR abrasion and fluid resistance with a PVC layer that strips predictably. |
| Three sheath colours, three article numbers | Grey, orange and yellow each carry their own number, so the colour is fixed by the order line rather than by a note. |
| UL/CSA approval and copper screening | Both are available across the range and quoted per order. |
Frequently Asked Questions
Q: What distinguishes SENSORFLEX from conventional JZ-500 control cables?
A: JZ-500 is a general-purpose control cable from 0.5 mm² upward with numbered black cores. SENSORFLEX runs 3 to 5 cores at 0.25 and 0.34 mm² in sensor colour sequences, at 4.4 to 5.9 mm outside diameter.
Q: How do I choose between PVC, PUR, and PVC/PUR sheath options?
A: A: PVC is the 15 x cable OD build with class 5 or 6 strands and a self-extinguishing, oil- and chemical-resistant PVC sheath. PUR is the class 6 extra-fine build at 7.5 x cable OD with low adhesion, high abrasion resistance and resistance to hydrolysis and microbial attack - that is the drag-chain variant. PVC/PUR keeps the PVC structure and puts a co-extruded PUR outer sheath over a PVC inner sheath, in yellow RAL 1021 to DESINA.
Q: What is the DESINA standard and why is yellow recommended?
A: DESINA is the standard the yellow sheath is specified against, at RAL 1021. The colour marks sensor and actuator circuits so they can be told apart from a motor feed without reading a label. Details of the standard are available on request.
Q: Why do 0.25 mm2 and 0.34 mm2 have different operating voltage ratings?
A:The rating steps at the cross-section: up to 0.25 mm² the peak working voltage is 350 V with a 1200 V AC test at 50 Hz; from 0.34 mm² upward it is 500 V with a 2000 V test. Both leave wide headroom over the 24 V DC these cables normally carry.
Q: Can SENSORFLEX operate inside drag chains? What is the bend radius?
A: PUR and PVC/PUR variants are specifically rated for drag-chain and dynamic motion, featuring a tight 7.5 x OD dynamic bend radius (just 33 mm for a 4.4 mm cable). Standard PVC is recommended for fixed installation (15 x OD) and should not be used in continuous high-speed drag chains.
Q: What do the three article numbers per line signify in the table?
A: They are three sheath colours of the same build: grey, orange and yellow RAL 1021. Each is a separate five-digit number - for 3 x 0.25 mm² PVC that is 73473 grey, 76076 orange and 76061 yellow. Quoting the number fixes both the colour and the sheath material.
Hot Tags: sensorflex sensor cable, China sensorflex sensor cable suppliers
Electrical & Thermal Baseline
|
Operating voltage |
Conductor |
Temperature, fixed |
Test voltage |
Cross-section range |
|
350 V / 500 V |
Class 5 / 6 fine copper |
−30 °C to +80 °C |
1200 V / 2000 V |
0.25 – 0.34 mm² (3–5 cores) |
Sensor Cable Electrical & Sheath Performance
Electrical & mechanical baseline parameters
|
Parameter |
Standard specification |
|
Conductor material |
High-purity annealed bare copper to DIN VDE 0295, BS 6360, and IEC 60228 |
|
Core insulation |
Special flame-retardant PVC compound with stable dielectric properties |
|
Flame retardance |
Compliant with IEC 60332-1 and DIN EN 60332-1-2 vertical single-cable flame test |
|
Insulation resistance |
Minimum 20 Mohm x km at 20 C |
|
Core stranding |
Cores stranded in layers at optimum pitch with back-twist to relieve internal tension |
|
Environmental compliance |
Cadmium-free, silicone-free, and free from paint-wetting impairment substances |
|
Regulatory directives |
Full CE Low Voltage Directive 2014/35/EU compliance; UL/CSA and screening optional |
Sheath variant comparative performance
|
Feature dimension |
Comparative characteristics |
|
Conductor flexibility |
PVC variant uses class 5 or 6 fine wire; PUR variant uses class 6 extra-fine stranded copper (superior flex fatigue resistance) |
|
Sheath wear & adhesion |
PUR sheath delivers low surface adhesion, high tear strength, and resistance to hydrolysis; PVC provides standard oil tolerance |
|
Dynamic bend radius |
PUR and PVC/PUR achieve a tight 7.5 x OD dynamic bend radius for drag chains; PVC requires 15 x OD |
|
Dual-layer construction |
PVC/PUR co-extrusion features an inner PVC cushion for fast stripping and an outer PUR shield against abrasives and fluids |
Sensor Cable Standards and Approvals
Conductor DIN VDE 0295 class 5/6 / IEC 60228 class 5/6 | Core insulation PVC | Flame retardance IEC 60332-1 / DIN EN 60332-1-2 | Machine tool industry DESINA standard (yellow RAL 1021) | Low Voltage Directive 2014/35/EU