Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of helukabel jz-500 control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Introduction to the JZ-500 Range
JZ-500 is a 300/500 V fixed-installation flexible control cable built on bare copper conductors to DIN VDE 0295 class 5 with special PVC insulation. It is intended for flexible routing under medium mechanical stress, where the cable moves freely but carries no tensile load and is not forced into a guided motion. A single family absorbs the site variables through six interchangeable variants: base grey PVC; black with UV resistance; orange for interlock identification; COLD down to −30 °C mobile; C black with tinned copper braid for EMC margin; and PUR for tear and coolant-emulsion resistance. With 2–100 cores, 0.5–185 mm² and AWG equivalents listed alongside five-digit article numbers, sheath, temperature and screening are settled in one selection round.
Select Between the Six JZ-500 Variants
Variant comparison
|
Item |
JZ-500 |
JZ-500 black |
JZ-500 orange |
JZ-500 COLD |
JZ-500 C black |
JZ-500 PUR |
|
Sheath material |
Special PVC TM2 |
Special PVC TM2 |
Special PVC TM2 |
Low-temp special PVC |
Special PVC TM2 |
Full PU TMPU |
|
Sheath colour |
Grey RAL 7001 |
Black RAL 9005 |
Orange RAL 2003 |
Black RAL 9005 |
Black RAL 9005 |
Grey RAL 7001 |
|
Core insulation |
PVC Z7225 |
PVC Z7225 |
PVC Z7225 |
PVC YI4 |
PVC Z7225 |
PVC TI2 |
|
Core marking |
Black / white |
Black / white |
Orange / black |
Black / white |
Black / white |
Black / white |
|
Mobile temp. |
-15 to +80 C |
-15 to +80 C |
-15 to +80 C |
-30 to +80 C |
-10 to +80 C |
-15 to +80 C |
|
Bending radius |
7.5x / 4x |
7.5x / 4x |
7.5x / 4x |
7.5x / 4x |
10x / 5x |
7.5x / 4x |
| Size range (mm²) | 0.5-185 | 0.5-35 | 1.0-2.5 | 0.5-6 | 0.5-35 | 0.5-16 |
|
Copper braid |
None |
None |
None |
None |
approx. 85 % |
None |
|
Radiation resistance |
80 Mrad |
80 Mrad |
80 Mrad |
80 Mrad |
80 Mrad |
100 Mrad |
|
Outdoor / UV |
Not for outdoor |
Yes |
Not for outdoor |
Outdoor yes / UV not stated |
Yes |
Yes, outdoor |
Select by site condition
|
Site condition |
Select |
Why |
|
Outdoor, UV exposure |
JZ-500 black |
Black PVC sheath is UV-tested; electrical data identical to the base type |
|
Ambient down to -30 °C |
JZ-500 COLD |
Low-temperature flexible sheath extends the mobile limit to -30 °C |
|
VFD, servo and EMC-sensitive circuits |
JZ-500 C black |
Tinned copper braid with approx. 85 % coverage, coupling resistance max. 250 Ω/km |
|
Coolant and cutting-fluid exposure |
JZ-500 PUR |
Full PU TMPU sheath resists tearing and coolant emulsions, 100 Mrad radiation resistance |
|
Interlock circuits requiring identification |
JZ-500 orange |
Orange cores with black numerals follow the EN 60204-1 / VDE 0113-1 practice for live interlock circuits |
|
Routine routing inside control cabinets |
JZ-500 (base type) |
The base build: same electrical and temperature data as black and orange |
Typical Applications




Why Specify JZ-500
|
JZ-500 design point |
What it changes on site |
|
Six variants on one page |
Sheath colour, low temperature, screening and chemical resistance compared in one pass instead of checking model by model |
|
Verifiable electrical margin |
4000 V test voltage, min. 8000 V breakdown voltage and min. 20 MΩ·km insulation resistance, matching the catalogue item by item |
|
EMC option available |
Tinned copper braid with approx. 85 % coverage and coupling resistance max. 250 Ω/km for VFD and servo surroundings |
|
Low temperature and outdoor covered |
COLD reaches -30 °C for mobile installation; black, COLD, C black and PUR are suitable for outdoor routing |
|
Delivery aligned to assembly |
Every size is metre-marked and cut to length, so cable and harness processing can ship together and offcuts stay minimal |
Screen Termination & Shield-Bond Practice (JZ-500 C black)
This section applies only to JZ-500 C black, the single shielded variant on this page. The five unscreened variants are not covered here: their green-yellow earth core serves protective earthing only and is not a substitute for a screen. The practice below is written around the screening figures given by the catalogue - approx. 85 % coverage, coupling resistance max. 250 Ω/km, core/screen withstand test voltage 2000 V, bending radius 10 x OD (mobile) / 5 x OD (fixed) and a mobile-installation temperature limit of -10 °C.
Bond the screen at both ends. The catalogue requires the screen of the finished cable to be fully and completely contacted on both ends; without that bond, the 85 % braid coverage does not turn into real interference immunity.
Prefer a 360-degree clamp. Crimp or clamp the braid over the full circumference with a shield clamp or metal ring instead of leading the braid to a terminal with a single wire. A long pigtail raises the high-frequency impedance of the screen and gives away the EMC advantage the C black variant was specified for.
Never share a crimp with a conductor. The core/screen withstand voltage is 2000 V, well below the 4000 V between cores, so the braid must not enter the same crimp barrel or the same terminal as a conductor.
Respect bending radius and temperature together. Leave a transition length for the screen so the cable exits the terminal without falling below 10 x OD; the -10 °C mobile limit also means the cable should not be bent cold.
Choose single-ended or double-ended bonding deliberately. Base the decision on the potential difference between the cabinet earth and the machine earth; where single-ended bonding is used, insulate the unbonded end so it cannot touch the enclosure by accident.
Verify continuity afterwards. Confirm a low-resistance path from the screen to the earth bar, and never use the screen as a PE conductor where power and signal cables share a route.
Frequently Asked Questions
Q: How do JZ-500 and JZ-500 black differ?
A: Conductor, insulation, voltage class and temperature range are identical; only the sheath differs. The base type uses grey PVC (RAL 7001); black uses black PVC (RAL 9005) and is UV-tested, so it can be routed outdoors. Choose black when the installation has to match black harnesses or exterior routing; for ordinary cabinet wiring the base type is sufficient.
Q: How should the screening performance of JZ-500 C black be assessed?
A: The variant applies a tinned copper braid over the cores with approx. 85 % coverage and a coupling resistance of max. 250 Ω/km, with a core/screen withstand test voltage of 2000 V. The trade-offs are a bending radius of 10 x OD mobile and 5 x OD fixed, and a mobile temperature limit of -10 °C. Both cable ends must be fully and completely bonded, otherwise the EMC benefit drops sharply; see section 6 for the practice.
Q: How do I choose between JZ-500 PUR and PURö-JZ?
A: Both use a full polyurethane TMPU outer sheath, so the decision comes down to the duty. For machining duty dominated by coolant emulsions and cutting fluids, JZ-500 PUR resists emulsions better and reaches 100 Mrad radiation resistance. For duty dominated by mineral oil immersion where a lower mobile temperature is needed, PURö-JZ uses oil-resistant PVC TI2 core insulation with a mobile limit of -20 C, and the catalogue notes that it helps the cores slide inside the sheath under external stress.
Q: What do the G and x part-number suffixes mean?
A: G denotes a green-yellow earth core (3 cores and above); x denotes no earth core, which corresponds to the OZ design in the catalogue. Both part numbers share the same outer diameter, weight and copper weight for a given size, so the choice is purely about the earth core.
Q: Can the cable be used in a cable carrier or continuous flexing?
A: Only under the conditions the catalogue states. The range is described as suitable for flexible applications that must withstand medium mechanical stress, move freely, carry no tensile load and are not forced into a guided motion, and the catalogue also notes that it can be used in a cable carrier under specific conditions. Where continuous reciprocating flexing is planned, send the travel distance, acceleration and cycle rate so the construction can be checked against those conditions, or so we can recommend a drag-chain rated alternative.
Q: How are samples and volume deliveries scheduled?
A: Selection and proposal confirmation are returned within 2 working days and standard volume delivery stays within 15 days, with an order range of 10-5,000 sets. Lead time for samples and non-standard sizes is confirmed at quotation against the size and quantity. Cables can be processed to a customer-nominated brand or supplied as an alternative solution.
Hot Tags: helukabel jz-500 control cable, China helukabel jz-500 control cable suppliers
Ratings Common to All Six JZ-500 Variants
|
Voltage class |
Conductor |
Temperature, fixed |
Dielectric test |
Size range |
|
300/500 V |
Class 5 bare copper |
−40 °C to +80 °C |
4000 V |
0.5 – 120 mm² (2–100 cores) |
Electrical, Mechanical & Sheath Parameters
Common specifications (all six variants)
|
Item |
Value |
|
Conductor |
Bare copper, fine strands; to DIN VDE 0295 class 5, BS 6360 class 5, IEC 60228 class 5 |
|
Core identification |
To DIN VDE 0293: black cores with continuous white numerals (orange variant: orange cores with continuous black numerals) |
|
Stranding |
Cores stranded in layers at optimum lay length |
|
Earth conductor |
Green-yellow earth core in the outer layer (3 cores and above); on the orange variant the JZ design includes it, the OZ design does not |
|
Rated voltage U0/U |
300 / 500 V |
|
Test voltage |
4000 V (C black: core/core 4000 V, core/screen 2000 V) |
|
Breakdown voltage |
min. 8000 V |
|
Insulation resistance |
min. 20 MΩ·km |
|
Flame retardance |
To DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent to DIN VDE 0472 part 804, test method B) |
|
Material declaration |
Cadmium-free, silicone-free, free from substances that impair paint wetting |
|
Length |
Metre-marked; any custom length available |
Variant-specific parameters
|
Item |
Difference |
|
Outer sheath |
Special PVC TM2 (DIN VDE 0207-363-4-1 / DIN EN 50363-4-1); COLD uses low-temperature flexible special PVC; PUR uses full polyurethane TMPU (DIN EN 50363-10-2) |
|
Core insulation |
Z7225 (base / black / orange / C black); YI4 (COLD); TI2 (PUR) |
|
Mobile-installation temperature limit |
-15 °C (base / black / orange / PUR); -30 °C (COLD); -10 °C (C black) |
|
Minimum bending radius |
7.5x / 4x (base / black / orange / COLD / PUR); 10x / 5x (C black) |
|
Screen |
Tinned copper braid, approx. 85 % coverage; coupling resistance max. 250 Ω/km (C black only) |
|
Radiation resistance |
Up to 80 Mrad; PUR up to 100 Mrad |
|
Chemical and weather resistance |
PUR is highly resistant to coolant emulsions; black / COLD / C black / PUR may be used outdoors |
Standards and Approvals Applied
Conductor DIN VDE 0295 class 5 / BS 6360 class 5 / IEC 60228 class 5 | Control cable DIN VDE 0285-525-2-51 / DIN EN 50525-2-51 (JZ-500 PUR: DIN VDE 0285-525-1 / DIN EN 50525-1) | Core identification DIN VDE 0293 | Flame retardance DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1 | PVC outer sheath DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 | PUR outer sheath DIN EN 50363-10-2 (PUR variant only) | Low Voltage Directive 2014/35/EU
Filtering the JZ-500 Part-Number Schedule
Part-number filtering — search by five-digit article number, filter by core count (2–100) and cross-section (0.5–120 mm²), or switch variant between the six sheaths; AWG equivalents are carried in the same row.
JZ-500 Part-Number Tables
AWG conversion
The table below gives the AWG equivalents marked in the catalogue against nominal cross-sections. AWG is an approximation and the actual cross-section is the mm² value; the part-number tables repeat the AWG column so drawings in imperial units can be checked directly. Sizes of 150 mm² and above are listed in kcmil in the catalogue.
|
Nominal mm² |
AWG |
Nominal mm² |
AWG |
|
0.5 |
20 |
0.75 |
19 |
|
1 |
18 |
1.5 |
16 |
|
2.5 |
14 |
4 |
12 |
|
6 |
10 |
10 |
8 |
|
16 |
6 |
25 |
4 |
|
35 |
2 |
50 |
1 |
|
70 |
2/0 |
95 |
3/0 |
|
120 |
4/0 |
150 / 185 |
300 / 350 kcmil |
Standard part-number tables
The tables cover 2, 3, 4, 5 and 7 cores in 0.5 to 2.5 mm². Each size exists as G (with green-yellow earth core, 3 cores and above) or x (without earth core, the OZ design); outer diameter, copper weight and total weight are identical for both. The full range of 2 - 100 cores up to 120 mm² is available on request.
JZ-500 Standard Size

JZ-500 Black Standard Sizes

JZ-500 Orange Standard Sizes

JZ-500 COLD Standard Sizes

JZ-500-C Black Standard Sizes

JZ-500 PUR Standard Sizes