HELUKABEL JZ-750 Control Cable

HELUKABEL JZ-750 Control Cable
Details:
JZ-750 industrial control cable, 450/750 V, grey RAL 7001 PVC TM2 sheath over special PVC TI2 insulation: 0.5-2.5 mm², 2-61 cores, numbered cores to DIN VDE 0293. Indoor only — outdoor use is excluded.

Standards & Compliance
DIN VDE 0285-525-2-51 / DIN EN 50525-2-51 | DIN VDE 0207-363-3 (TI2) / 363-4-1 (TM2) | VDE 0295 cl. 5 | IEC 60332-1-2 | CE 2014/35/EU

Quick Specs
450/750 V | 0.5-2.5 mm², 2-61 cores | 7.5 × OD / 4 × | −15 to +80 °C mobile / −40 to +80 °C fixed | 4000 V test
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of helukabel jz-750 control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Where the 450/750 V Range Applies

 

JZ-750 addresses control and measuring circuits where the drawing calls for 450/750 V and the system has to stay in PVC. The conductor remains bare copper to DIN VDE 0295 class 5, the core insulation moves to special PVC TI2 (DIN VDE 0207-363-3 / DIN EN 50363-3), and the outer sheath is grey special PVC TM2, which allows a 7.5 x OD mobile bending radius in dry, damp and wet indoor areas. The range runs from 2 cores of 0.5 mm² up to 61 cores, with continuous white numerals that are underlined so rows are not misread during termination. The catalogue flags the range separately as strongly oil resistant and points to the technical information tables for oil and chemical resistance.

 

Voltage Class, Core Count and Cross-Section Selection

 

Voltage class and where it applies

A 450/750 V rating usually appears for one of three reasons: the drawing states it, the customer asks for an internationally recognised PVC control or measuring cable, or an exported machine has to satisfy certification. This range keeps conductor and sheath inside the PVC system and raises only the insulation grade and wall thickness, so there is no need to switch to an XLPE design for 450/750 V duty. The price is size and weight: at 2 x 0.5 mm2 the outer diameter is 5.7 mm and the unit weight 48.0 kg/km, well above the 4.8 mm / 40.0 kg/km of the 300/500 V version of the same family, so terminal clearance and duct fill must be re-checked against the new diameter. Where the circuit stays at 300/500 V, the slimmer 300/500 V version in the same family uses less material.

 

Typical Applications

 

01control-circuits-in-exported-machinery-machine-cabinet-door-open-on-breakers-and-relays-grey-control-cables-glanded-at-the-spindle-head

Control circuits in exported machinery
A drawing issued at 450/750 V that has to stay in PVC can be built as drawn, and this range covers any place where an internationally recognised PVC cable is required.

02fixed-and-moving-routing-inside-industrial-machinery-grey-cable-bundle-clamped-out-of-the-enclosure-into-a-drag-chain-along-the-machine-bed

Fixed and moving routing inside industrial machinery
Medium mechanical stress with free movement, but no tensile load and no forced movement, is the duty this range is rated for, at a 7.5 x OD mobile bending radius.

03control-circuits-on-transmission-systems-and-conveyors-belt-conveyor-head-with-a-gear-motor-a-sensor-and-grey-cables-clipped-to-the-frame

Control circuits on transmission systems and conveyors
It is built to DIN VDE 0285-525-2-51 / DIN EN 50525-2-51 as a control or measuring cable for industrial machinery, transmission systems and industrial plant.

04measuring-circuits-in-damp-areas-stainless-tank-wall-with-a-ph-and-a-conductivity-probe-a-junction-box-and-a-display-unit-above-a-wet-floor

Measuring circuits in damp areas
Dry, damp and wet indoor areas are the stated envelope for both control and measuring duty - outdoor use is excluded.

 

Fluid, UV and Cleaning-Medium Compatibility

 

The catalogue calls out the fluid capability of this range separately, so it should not be summarised as a generic PVC cable. The table aligns three common environments with what the catalogue actually states.

 

Medium / environment

What the catalogue states and what to do

Mineral oil

Called out as strongly oil resistant - a first choice for oily environments; the specific oil and temperature should still be confirmed with engineering

Coolant emulsions, weak acid or alkaline wash-down

Not specified item by item; the catalogue refers to the technical information tables, so each medium must be checked rather than assumed

Outdoor UV and permanent sunlight

Outdoor use is explicitly excluded - UV-loaded routes belong to a black-sheathed or polyurethane variant

 

Step 1

Identify the medium. Mineral oil is where this range performs; coolant emulsions and wash-down agents must be checked against the technical information tables first.

Step 2

Decide on UV exposure. Outdoor use is excluded for this range, so do not work around it with a sleeve; change the sheath material instead.

Step 3

Settle the cleaning method. Where high-pressure steam or aggressive solvents are used, confirm the PVC sheath boundary at drawing stage.

 

Why Specify JZ-750

 

450/750 V design point

Site benefit

Voltage class matches international drawings

No switch to an XLPE design for 450/750 V duty, so the selection chain stays unchanged

Underlined core numerals

Rows are not misread during termination, which cuts fault-tracing time on large core counts

Oil resistance called out separately

Oily environments need no extra protective sleeve, so fewer maintenance parts

Same family as the 300/500 V version

Mixed projects share one cutting and processing flow, simplifying stock planning

Metre marking and cut-to-length supply

Offcuts stay predictable and on-site re-ordering drops

 

Frequently Asked Questions

 

Q: Can 450/750 V and 300/500 V versions be used interchangeably?

A: No. The rated voltages differ, and this range carries thicker insulation and sheath: at 2 x 0.5 mm2 the outer diameter and weight are 5.7 mm / 48.0 kg/km against 4.8 mm / 40.0 kg/km for the 300/500 V version. Terminal clearance, duct fill and bending space must all be re-checked against the larger diameter.

Q: Why are the core numerals underlined?

A: The cores use black insulation with continuous white numerals, and the catalogue notes that the numerals are underlined to avoid confusion. On higher core counts, such as 21 cores and above, the underline makes the break between adjacent numbers clearer and reduces the chance of terminating the wrong row.

Q: Which document confirms the oil resistance?

A: The catalogue marks this range as strongly oil resistant and refers readers to the technical information tables for oil and chemical resistance item by item. Because behaviour varies with oil type, concentration and temperature, provide the medium and working temperature at selection stage so that engineering can confirm each item.

Q: Can it be used outdoors or buried?

A: No. Outdoor use is excluded for this range. Where UV exposure is involved, select a black-sheathed or polyurethane variant and re-check that model's temperature and bending radius.

Q: What is the difference between G and x, and can a 2-core cable have an earth core?

A: G denotes a green-yellow earth core, which the catalogue offers from 3 cores upwards; x denotes no earth core and corresponds to the OZ design. Two-core sizes are listed with x only, because a green-yellow earth core needs a separate third core and cannot be provided within a 2-core construction.

Q: What are the size range, lead time and order quantity?

A: The catalogue covers 2 - 61 cores in 0.5 - 2.5 mm2 with article numbers 10800 - 10880, and the table above lists that complete range rather than a selection of it: five cross-sections (0.5 / 0.75 / 1 / 1.5 / 2.5 mm2) across 2 to 61 cores, with the G (earth core) and x (OZ) article numbers shown side by side. Selection and proposal confirmation are returned within 2 working days and standard volume delivery stays within 15 days, with an order range of 10-5,000 sets; lead time for samples and non-standard sizes is confirmed at quotation.

 

 

Hot Tags: helukabel jz-750 control cable, China helukabel jz-750 control cable suppliers

General Ratings Common to This Range

 

Rated voltage

Conductor

Temperature (fixed)

Test voltage

Available sizes

450/750 V

Class 5 bare copper

−40 °C to +80 °C

4000 V

0.5 – 2.5 mm² (2–61 cores)

 

Ratings and Differences from the 300/500 V Range

 

General specifications

Item

Value

Conductor

Bare copper, fine strands; to DIN VDE 0295 class 5, BS 6360 class 5 and IEC 60228 class 5

Core insulation

Special PVC TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3

Stranding

Cores stranded in layers at optimum lay length

Earth conductor

Green-yellow earth core in the outer layer (3 cores and above)

Test / breakdown voltage

Test voltage 4000 V; breakdown voltage min. 8000 V

Insulation resistance

min. 20 Mohm x km

Flame retardance

DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent to DIN VDE 0472 part 804, test method B)

Radiation resistance

up to 80 Mrad

Material declaration

Cadmium-free, silicone-free, free from substances that impair paint wetting


Differences from the 300/500 V version

Item

Difference

Voltage class

450/750 V (the 300/500 V version of the same family is rated 300/500 V)

Core insulation material

Special PVC TI2 (the 300/500 V version uses special PVC Z7225)

Wall thickness and size

Thicker insulation and sheath: 2 x 0.5 m㎡ measures 5.7 mm / 48.0 kg/km against 4.8 mm / 40.0 kg/km for the 300/500 V version at the same size

Positioning

The catalogue states it may be used wherever an internationally recognised PVC cable is required, while the 300/500 V version is aimed mainly at machine tools and production lines

 

Standards Referenced by This Range

 

Conductor DIN VDE 0295 class 5 / BS 6360 class 5 / IEC 60228 class 5 | Control cable DIN VDE 0285-525-2-51 / DIN EN 50525-2-51 | Core insulation DIN VDE 0207-363-3 / DIN EN 50363-3 | Core identification DIN VDE 0293 | Outer sheath DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 | Flame retardance DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1 | Low Voltage Directive 2014/35/EU

 

Filtering Four Cross-Sections and 61 Core Counts

 

Part-number filtering — five nominal cross-sections; filter by core count (2–61) and 0.5–2.5 mm², or switch between the G (earth core) and x columns.

 

JZ-750 Standard Part Numbers

 

AWG conversion (this range only)

This range uses five nominal cross-sections; the AWG equivalents marked in the catalogue are listed below. AWG is an approximation and the actual cross-section is the m㎡ value.

 

Nominal m㎡

AWG

Nominal m㎡

AWG

0.5

20

0.75

19

1

18

1.5

16

2.5

14

   

 

JZ-750 standard part numbers

01 JZ-750 standard part-number table G and x article numbers two-column layout

 

Send Inquiry