H05VV-F — 300/500 V PVC Sheathed Flexible Cord

H05VV-F — 300/500 V PVC Sheathed Flexible Cord
Details:
H05VV-F is the 300/500 V flexible cord of the H series; H05VVH2-F is the same core and the same sheath in the oblate profile. Conductors are fine-wired bare copper to DIN VDE 0295 cl.5, the insulation is PVC TI2 and the sheath PVC TM2, on a rated conductor temperature of 70 °C.
Standards & Compliance
EN 50525 reference standard | DIN VDE 0295 cl.5 conductor | PVC TI2 insulation / PVC TM2 sheath | IEC 60332.1 flame test
Quick Specs
300/500 V | 70 °C | 0.75 to 2.5 mm2, 2 to 5 cores | Round and oblate (H2) | Fine-wired bare copper, cl.5
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of h05vv-f — 300/500 v pvc sheathed flexible cord in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

H05VV-F cord is the 300/500 V sheathed cord of the H series, and it is the tier that takes the supply side of an appliance lead. The construction is fine-wired bare copper to DIN VDE 0295 cl.5, PVC TI2 core insulation and a PVC TM2 sheath, on a rated conductor temperature of 70 °C. Sections run from 0.75 mm² to 2.5 mm² in 2, 3, 4 and 5 cores, which is what separates it from the lighter 300/300 V cord rather than any change of compound. H05VVH2-F carries the same core and the same sheath in the oblate profile.

 

The Tier That Reaches 2.5mm²

 

The section range is the practical difference between this cord and the lighter tier. From 0.75 mm² up to 2.5 mm², with a core count that goes to five, the cord covers a supply lead for a workshop machine as readily as it covers a household appliance. The five-core version is what makes that possible without moving to a control cable: three cores for the supply including the protective conductor, and two more for a switched function or a signal alongside it.

 

Fixed installation is rated from -10 °C and flexing from -5 °C, both up to +70 °C. The minimum bending radius is 6D fixed and 13D flexing, measured on the outer diameter, and the flame requirement is IEC 60332.1.

 

Products Description

 

The H2 suffix describes the envelope, not the electrical construction. Round and oblate carry the same fine-wired conductor and the same PVC TI2 insulation at a given section; what changes is how they occupy space. The oblate version is offered in two cores only, at 0.75 mm² and 1.0 mm², and its dimensions are given as a width by a height: 3.9 mm by 6.2 mm at 0.75 mm² and 4.1 mm by 6.6 mm at 1.0 mm².

 

Where the 300/500 V Cord Is Specified

appliance-supply-leads-single-core-power-wiring
Appliance supply leads
power-lighting-wiring-industrial-building-illumination
Power lighting
instrumentation-runs-signal-power-wiring-field-transmitters
Instrumentation runs
flat-routes-cable-wiring-confined-space-installation
Flat routes

 

Specification Questions

 

Q: What is this cord rated for?

A: 300/500 V at a rated conductor temperature of 70 °C, with fixed installation from -10 °C and flexing from -5 °C. It is the supply-side tier of the PVC cord range.

Q: Which sections and core counts are available?

A: From 0.75 mm2 to 2.5 mm2 in 2, 3, 4 and 5 cores, round. The five-core version carries three supply cores plus two for a switched function or a signal.

Q: Which sizes does the oblate version come in?

A: Two cores only, at 0.75 mm2 and 1.0 mm2. The envelope is 3.9 mm by 6.2 mm at 0.75 mm2 and 4.1 mm by 6.6 mm at 1.0 mm2, with the same tolerance on both dimensions.

Q: How is the outer diameter read for the oblate version?

A: As a width and a height rather than a single figure, width written first. A round two-core 0.75 mm2 cord measures 6.3 mm; the same section in the oblate version measures 3.9 mm by 6.2 mm.

Q: What bending radius applies?

A: 6D for fixed installation and 13D where the cord is flexed in service, on the outer diameter of the core count being used. A five-core 2.5 mm2 cord at 12.5 mm therefore takes a 75 mm fixed radius.

Q: What tolerances apply to the diameters?

A: Plus or minus 0.4 mm on the two-core range and on three- and four-core cords at 0.75 and 1.0 mm2; plus or minus 0.6 mm on three- and four-core at 1.5 and 2.5 mm2 and on the whole five-core range. The oblate entries carry the same tolerance on both dimensions.

Q: Can the cord be supplied as a finished lead?

A: Yes. The cord is cut to length, and where a terminated lead is preferred the same construction is assembled to the drawing. Cord and assembly are quoted in one document.

 

Requesting a 300/500 V Cord

 

Send the core count, the section, the length and the colour requirement, and state whether the round or the oblate profile is wanted. Where the lead is to be terminated, add the termination and it is quoted alongside the cord.

 

 

Hot Tags: h05vv-f — 300/500 v pvc sheathed flexible cord, China h05vv-f — 300/500 v pvc sheathed flexible cord suppliers

Ratings of the Two Profiles

 

Designation Rated voltage Conductor Insulation Outer sheath Temperature range
H05VV-F 300/500 V Fine-wired bare copper, cl.5 PVC TI2 PVC TM2 -10 to +70 °C fixed; -5 to +70 °C flexing
H05VVH2-F 300/500 V Fine-wired bare copper, cl.5 PVC TI2 PVC TM2 -10 to +70 °C fixed; -5 to +70 °C flexing