YSLY 300-500V Unshielded PVC Control Cable

YSLY 300-500V Unshielded PVC Control Cable
Details:
YSLY is the unshielded build of the PVC control range, made for the wiring that runs inside a machine. With nothing
between the cores and the sheath the run bends continuously in a drag chain instead of being held to occasional movement, and the cable strips clean at the terminal with no braid to dress back.

Standards & Compliance
HD 21.13 | GB/T 5023 | GB/T 3956 conductor | GB/T 18380.12 flame retardant
Quick Specs
300/500 V | 70 °C conductor | 6 x OD fixed / 13 x OD moving | PVC/D over PVC/ST9, no screen
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of ysly 300-500v unshielded pvc control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Lead Paragraph

 

YSLY control cable is the unshielded member of the PVC control range, and the trade orders this construction as a yy cable. Four layers make it: a bare annealed stranded copper conductor to GB/T 3956, a PVC/D insulation, no screen of any kind, and a PVC/ST9 outer sheath, rated 300/500 V with a maximum conductor operating temperature of 70 °C. The schedule runs from 2 to 36 cores over seven cross-sections, 179 combinations in all, so what a machine drawing asks for is usually already covered.Because nothing sits between the cores and the sheath, the cable keeps the freedom a braid takes away: control units that have to be re-routed, and machine areas where the run moves, without tensile load and without forced movement.

 

The Layer That Is Not There

 

The differentiator on YSLY is a layer that does not exist. A tinned copper braid, laid over the cores and under the sheath, stiffens the cable in bending and concentrates flexing stress at the point where the braid wires cross; that is why a screened control cable is not recommended for continuous bending.Take the braid out and the same PVC wall and sheath bends to 13 x OD on the move: the run is re-routed by hand, and it is neither pulled nor forced along its route.

 

The condition has limits, and they are physical rather than administrative.  Where either condition cannot be met, the continuous-bending duty does not apply, whatever the construction.

 

Typical Applications

 

cable-cores-landed-on-terminal-rail-machine-tool-enclosure-1536x1536

Machine-tool internal wirin
Carries control and interlock circuits between the assemblies inside a machine tool, landed on terminal rails.

cable-run-along-crane-bridge-panel-1536x1536

Lifting and transport equipment
Panel-to-device wiring inside cranes, hoists and transport equipment, with every run kept inside the machine frame.

cable-service-loop-at-hinged-panel-door-1536x1536

Control units with a bending requirement
Where a guard or a panel door swings through a stroke, and the cable bends occasionally rather than all day.

unshielded-cable-through-open-energy-chain-drag-chain-1536x1536

Moving machine areas
Occasional movement inside a machine frame, with the cable free and not clamped into a bend.

That matters for screening: a braid earns its cost where a cable runs beside a drive output or leaves an enclosure, and costs bending life where a cable flexes all day. YSLY is specified on the second kind of route.

 

Two Installation Conditions, Read Separately

 

The range carries two installation ratings, and they are not averaged. Fixed installation takes a minimum bend radius of 6 x outer diameter over an ambient range of -10 to +70 °C. Moving installation takes 13 x outer diameter, and the cold end of the ambient range tightens to -5 °C while the hot end stays at +70 °C. Where one route carries both conditions - a fixed loom that passes through a moving guard, for instance - plan the whole run on the more severe of the two, and do not switch criteria part-way along it.

 

Colour and Compound Are Settled at the Order

 

Core identification colours, the jacket colour, and both compounds are made to order on this range. A panel shop can therefore match an existing drawing without re-labelling cores after the fact, and a machine builder can keep one colour convention across a loom even where the cable changes size. State the core colour convention with the enquiry, particularly where one multicore carries both power and control cores.

 

Frequently Asked Questions

 

Q: What does YSLY mean, and what is a yy cable?

A: YSLY is the type designation of this construction: PVC insulated, PVC sheathed, unscreened, 300/500 V. The trade short form yy comes from the two material letters - the first for the PVC insulation, the second for the PVC sheath - so yy cable and yy control cable both name the unscreened build. The lettering describes a construction family, not one maker product.

Q: What minimum bend radius applies?

A: 6 x outer diameter for fixed installation and 13 x outer diameter for moving installation, both measured on the cable outer diameter.

Q: What ambient temperature range applies?

A: -10 to +70 °C for fixed installation and -5 to +70 °C for moving installation, with a maximum conductor operating temperature of 70 °C in either case.

Q: How does a yy cable differ from a cy or an sy cable?

A: The three short forms describe the same PVC control build with different screening: yy has none, cy carries a tinned copper braid and sy a steel wire braid. Only the unscreened build is the one specified where the run moves.

Q: Which standards does the cable reference?

A: HD 21.13 and GB/T 5023, with the conductor to GB/T 3956. Flame retardancy is tested to GB/T 18380.12.

Q: Is oil resistance included?

A: Oil resistance is tested to GB/T 2951.5 and the referenced ASTM method. Resistance to oil, cold, acid, alkali and solvents is available as an option, so name it on the enquiry wherever the route passes a wash-down area.

Q: Can the construction be used where the run moves?

A: The installation decides, not a travel figure: the run may move, but it must not be pulled and must not be forced into a bend. A carrier that clamps the cable, or drags it under tension, is outside the stated duty.

Q: How is the size specified?

A: By core count and conductor cross-section together - for example 4 core at 0.75 mm2, or 12 core at 0.5 mm2 - because the schedule is built on those two axes. Give both figures on the enquiry; a size is quoted only where the two appear together in the schedule.

 

Hot Tags: ysly 300-500v unshielded pvc control cable, China ysly 300-500v unshielded pvc control cable suppliers

Electrical, Thermal and Fire Ratings

 

Parameter

Rating

Rated voltage U0/U 300/500 V
Maximum conductor operating temperature 70 °C
Ambient temperature, fixed installation

-10 to +70 °C 

Ambient temperature, moving installation -5 to +70 °C
Minimum bend radius, fixed 6 x outer diameter
Minimum bend radius, moving 13 x outer diameter
Flame retardancy Tested to GB/T 18380.12
Oil resistance Tested to GB/T 2951.5 and the referenced ASTM method
Reference standards HD 21.13 and GB/T 5023; conductor to GB/T 3956

 

Construction

 

Element Material Note

Conductor

Bare annealed stranded copper To GB/T 3956

Insulation

PVC/D Wall thickness, cutting and stripping ease declared with the build
Screen None The absent layer is what allows the continuous-bending duty
Outer sheath PVC/ST9 Colour and compound to order
Core identification To customer requirement Produced at the order stage

 

Installation Reference

 

Installation Minimum bend radius Ambient temperature range
Fixed installation 6 x outer diameter -10 to +70 °C
Moving installation 13 x outer diameter -5 to +70 °C

 

Send Inquiry