Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of ysly 300-500v unshielded pvc control cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.
Lead Paragraph
YSLY control cable is the unshielded member of the PVC control range, and the trade orders this construction as a yy cable. Four layers make it: a bare annealed stranded copper conductor to GB/T 3956, a PVC/D insulation, no screen of any kind, and a PVC/ST9 outer sheath, rated 300/500 V with a maximum conductor operating temperature of 70 °C. The schedule runs from 2 to 36 cores over seven cross-sections, 179 combinations in all, so what a machine drawing asks for is usually already covered.Because nothing sits between the cores and the sheath, the cable keeps the freedom a braid takes away: control units that have to be re-routed, and machine areas where the run moves, without tensile load and without forced movement.
The Layer That Is Not There
The differentiator on YSLY is a layer that does not exist. A tinned copper braid, laid over the cores and under the sheath, stiffens the cable in bending and concentrates flexing stress at the point where the braid wires cross; that is why a screened control cable is not recommended for continuous bending.Take the braid out and the same PVC wall and sheath bends to 13 x OD on the move: the run is re-routed by hand, and it is neither pulled nor forced along its route.
The condition has limits, and they are physical rather than administrative. Where either condition cannot be met, the continuous-bending duty does not apply, whatever the construction.
Typical Applications




That matters for screening: a braid earns its cost where a cable runs beside a drive output or leaves an enclosure, and costs bending life where a cable flexes all day. YSLY is specified on the second kind of route.
Two Installation Conditions, Read Separately
The range carries two installation ratings, and they are not averaged. Fixed installation takes a minimum bend radius of 6 x outer diameter over an ambient range of -10 to +70 °C. Moving installation takes 13 x outer diameter, and the cold end of the ambient range tightens to -5 °C while the hot end stays at +70 °C. Where one route carries both conditions - a fixed loom that passes through a moving guard, for instance - plan the whole run on the more severe of the two, and do not switch criteria part-way along it.
Colour and Compound Are Settled at the Order
Core identification colours, the jacket colour, and both compounds are made to order on this range. A panel shop can therefore match an existing drawing without re-labelling cores after the fact, and a machine builder can keep one colour convention across a loom even where the cable changes size. State the core colour convention with the enquiry, particularly where one multicore carries both power and control cores.
Frequently Asked Questions
Q: What does YSLY mean, and what is a yy cable?
A: YSLY is the type designation of this construction: PVC insulated, PVC sheathed, unscreened, 300/500 V. The trade short form yy comes from the two material letters - the first for the PVC insulation, the second for the PVC sheath - so yy cable and yy control cable both name the unscreened build. The lettering describes a construction family, not one maker product.
Q: What minimum bend radius applies?
A: 6 x outer diameter for fixed installation and 13 x outer diameter for moving installation, both measured on the cable outer diameter.
Q: What ambient temperature range applies?
A: -10 to +70 °C for fixed installation and -5 to +70 °C for moving installation, with a maximum conductor operating temperature of 70 °C in either case.
Q: How does a yy cable differ from a cy or an sy cable?
A: The three short forms describe the same PVC control build with different screening: yy has none, cy carries a tinned copper braid and sy a steel wire braid. Only the unscreened build is the one specified where the run moves.
Q: Which standards does the cable reference?
A: HD 21.13 and GB/T 5023, with the conductor to GB/T 3956. Flame retardancy is tested to GB/T 18380.12.
Q: Is oil resistance included?
A: Oil resistance is tested to GB/T 2951.5 and the referenced ASTM method. Resistance to oil, cold, acid, alkali and solvents is available as an option, so name it on the enquiry wherever the route passes a wash-down area.
Q: Can the construction be used where the run moves?
A: The installation decides, not a travel figure: the run may move, but it must not be pulled and must not be forced into a bend. A carrier that clamps the cable, or drags it under tension, is outside the stated duty.
Q: How is the size specified?
A: By core count and conductor cross-section together - for example 4 core at 0.75 mm2, or 12 core at 0.5 mm2 - because the schedule is built on those two axes. Give both figures on the enquiry; a size is quoted only where the two appear together in the schedule.
Hot Tags: ysly 300-500v unshielded pvc control cable, China ysly 300-500v unshielded pvc control cable suppliers
Electrical, Thermal and Fire Ratings
| Parameter |
Rating |
| Rated voltage U0/U | 300/500 V |
| Maximum conductor operating temperature | 70 °C |
| Ambient temperature, fixed installation |
-10 to +70 °C |
| Ambient temperature, moving installation | -5 to +70 °C |
| Minimum bend radius, fixed | 6 x outer diameter |
| Minimum bend radius, moving | 13 x outer diameter |
| Flame retardancy | Tested to GB/T 18380.12 |
| Oil resistance | Tested to GB/T 2951.5 and the referenced ASTM method |
| Reference standards | HD 21.13 and GB/T 5023; conductor to GB/T 3956 |
Construction
| Element | Material | Note |
|
Conductor |
Bare annealed stranded copper | To GB/T 3956 |
|
Insulation |
PVC/D | Wall thickness, cutting and stripping ease declared with the build |
| Screen | None | The absent layer is what allows the continuous-bending duty |
| Outer sheath | PVC/ST9 | Colour and compound to order |
| Core identification | To customer requirement | Produced at the order stage |
Installation Reference
| Installation | Minimum bend radius | Ambient temperature range |
| Fixed installation | 6 x outer diameter | -10 to +70 °C |
| Moving installation | 13 x outer diameter | -5 to +70 °C |