SUPER-PAAR-TRONIC-C-PUR Drag Chain D Cable

SUPER-PAAR-TRONIC-C-PUR Drag Chain D Cable
Details:
Halogen-free screened paired PUR data cable for continuous-flex carrier tracks — 0.25 to 1.0 mm², 1 to 14 pairs, 350 V nominal. Cut to length from factory stock.

Standards & Compliance
DIN VDE 0812 paired | DIN VDE 0295 cl. 6 col. 4 | DIN 47100 | DIN EN 50363-10-2 TMPU | CE 2014/35/EU

Quick Specs
350 V | 0.25-1.0 mm², 1-14 pairs | 7.5 × OD (0.25 mm²) / 10 × OD (0.5-1.0 mm²) moving, 4 × / 5 × fixed | −30 to +70 °C moving / −40 to +70 °C fixed | 1500 V test
Send Inquiry
Download
Overview
Technical Specifications
Part Numbers
Part Number & specification Verification | Availability & Lead Time Confirmation

Xiamen Kabasi Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of super-paar-tronic-c-pur drag chain d cable in China. If you're going to buy bulk durable cables made in China, welcome to get pricelist from our factory. All customized cables are with high quality and competitive price.

 

Positioning of the Multi-Shift Data Cable

 

SUPER-PAAR-TRONIC-C-PUR is the paired member of the drag-chain range: two cores twisted into a pair, pairs laid in low-torsion layers, a non-woven fleece tape over the assembly, an 85 % tinned copper braid, and a full TMPU jacket on a grey RAL 7001 sheath with metre marking. The PP insulation keeps friction between the pairs low; the fleece keeps the assembly off the braid; the braid takes the high-frequency interference that a drive throws at a signal pair. Rated 350 V nominal, −30 to +70 °C in motion, and up to 30 m of travel at 4 m/s and 50 m/s².

 

Why Specify SUPER-PAAR-TRONIC-C-PUR

 

Why global machine builders and turnkey automation contractors standardize on SUPER-PAAR-TRONIC-C-PUR for multi-shift carrier tracks:

 

Design point

Multi-shift benefit

Non-woven fleece wrap over the core assembly Keeps the pairs off the braid, so cyclic flexing does not rub insulation against copper.
DIN VDE 0295 class 6 extra-fine stranding Fine strands bend instead of work-hardening; that is what the class 6 designation buys in a carrier.
Full TMPU jacket Cut and abrasion resistance for swarf and carrier-wall contact, and flexibility retained to −30 °C.
DIN 47100 paired core identification Pairs are identified at both ends, so a 14-pair run can be terminated without ringing out.
Oil, solvent, acid, alkali and hydraulic-fluid resistance Keeps the jacket compound in service in wet machining cells.
100 Mrad radiation tolerance For plant where the cable runs near radiation sources; a niche figure, stated because the catalogue states it.

 

Multi-Shift Torsion, Coolant and Installation Discipline

 

In automated production cells and multi-axis robot drag chains operating continuously around the clock, data cables endure simultaneous planar bending, mild torsional rotation, and high-pressure coolant washdown. Installation must adhere to four essential rules:

 

Fleece Wrap and Low-Friction PP Insulation

A non-woven fleece wrap over the core assembly, plus low-friction PP insulation, keeps cores sliding instead of chafing.

01

Torsion-Free Installation

Never twist the cable into the trough: unreel it tangentially from the reel and lay it straight before fixing one end.

02

Chemical and Coolant Resistance

TMPU sheath to EN 50363-10-2, resistant to oils, solvents, acids, alkalis and hydraulic fluids.

03

Mutual Capacitance

Mutual capacitance about 135 nF/km and coupling resistance no more than 250 Ω/km - the two figures that decide how far a pair carries signal.

04

 

Typical Applications

 

01multi-shift-heavy-duty-cnc-metal-cutting-center-three-axis-guide-carriers-24-7-machining-under-coolant-washdown-and-rapid-axis-reversals

Multi-shift heavy-duty CNC metal cutting center three-axis guide carriers
Continuous 24/7 machining of automotive and aerospace components subject to uninterrupted coolant washdown and rapid axis reversals. Internal fleece wrap ensures zero downtime.

02industrial-welding-robot-auxiliary-linear-tracks-and-7th-axis-gantries-long-travel-transfer-rails-tmpu-jacket-against-weld-noise

Industrial welding robot auxiliary linear tracks and 7th-axis gantries
Long-travel high-speed transfer rails. Abrasion-resistant TMPU jacket withstands rough mechanical wear while shielding sensitive sensor networks from high-current welding electrical noise.

03heavy-duty-harbor-cranes-and-container-terminal-automated-grab-bucket-control-loops-dockside-uv-ozone-and-pull-on-a-high-tensile-jacket

Heavy-duty harbor cranes and container terminal automated grab bucket control loops
Outdoor and marine dockside handling equipment exposed to intense UV radiation, ozone degradation, and heavy mechanical pull forces. High tensile strength jacket ensures all-weather reliability.

04automated-high-density-warehouse-high-speed-stacker-crane-vertical-hoist-channels-7-5-x-od-at-0-25-mm2-and-10-x-od-up-to-1-0-mm2

Automated high-density warehouse high-speed stacker crane vertical hoist channels
Vertical lift masts experiencing rapid high-acceleration hoisting. Paired cabling geometry rejects nearby hoist motor electrical noise, while7.5 × OD at 0.25 mm² and 10 × OD up to 1.0 mm² keeps it inside a compact bellows.

 

Frequently Asked Questions

 

Q: What is the primary operational advantage of SUPER-PAAR-TRONIC-C-PUR over standard PVC cables?

A: The decisive advantages lie in mechanical abrasion resistance and chemical coolant durability:the full TMPU polyurethane jacket is specified for high tensile strength and abrasion resistance, and it stays flexible down to −30 °C in motionand never softens or cracks under prolonged cutting oil washdown. The inner non-woven fleece wrap reduces internal core friction, supporting continuous 24/7 multi-shift operations.

Q: How does the "low-torsion layer lay cabling" construction extend carrier service life?

A: Conventional concentric cables subject inner cores to excessive compression and outer cores to tension during flexing, creating spiral corkscrewing stresses that destroy the cable. Low-torsion paired assembly back-twists pairs during stranding, releasing residual rotary stress so conductors glide harmoniously within the carrier track.

Q: What does the specified mutual capacitance of ~135 nF/km mean in engineering practice?

A: Mutual capacitance defines AC capacitive loading on weak signal circuits. The specialized PP insulation stabilizes capacitance at approx. 135 nF/km, providing responsive signal edge transitions in 350V instrumentation circuits without excessive high-frequency capacitive attenuation from the dense screen.

Q: Can this cable operate reliably inside drag chains under freezing winter conditions?

A: Yes. Benefiting from the native low-temperature polymer flexibility of TMPU full polyurethane, it withstands dynamic flexure down to -30 C in continuous motion and down to -40 C in fixed installations, preventing brittle jacket fracture in unheated winter plants.

Q: Why is a paired twisted construction mandatory in high-noise manufacturing environments?

A: Standard parallel or concentric cables experience unequal noise voltage induction across conductors when exposed to inverter drive harmonics, generating differential interference. Twisted pairs ensure induced noise voltages cancel out symmetrically, while the 85% tinned copper braid reflects external radiated pulses.

Q: How do I verify part numbers and pair counts when ordering SUPER-PAAR-TRONIC-C-PUR?

A: The series utilizes standard 5-digit HELUKABEL part numbers (19101 to 19141). Specifications are denoted as "Pairs x 2 x Cross-Section" (e.g., 4 x 2 x 0.5 designates 4 pairs, 8 cores, 0.5 mm2, corresponding to Part No. 19122), directly searchable in the part-number schedule.

 

 

Hot Tags: super-paar-tronic-c-pur drag chain d cable, China super-paar-tronic-c-pur drag chain d cable suppliers

Drag-Chain Operating Envelope - Travel up to 30 m, speed up to 4 m/s, acceleration up to 50 m/s², up to 9 million cycles. One cycle is one complete out-and-back; cycle figures apply only with correct professional installation. 

Multi-Shift Baseline Ratings

 

Rated voltage

Conductor

Fixed temperature

Moving temperature

Test voltage

Pair range

350 V nominal

Class 6 extra-fine copper

−40 °C to +70 °C

−30 °C to +70 °C

1500 V

0.25 – 1.0 mm² (1–14 pairs)

 

Data Cable Standards and Directive

 

Conductor DIN VDE 0295 cl. 6 col. 4 / IEC 60228 / BS 6360 | Paired DIN VDE 0812 | Core ID DIN 47100 | Jacket TMPU to DIN EN 50363-10-2 | Low Voltage Directive 2014/35/EU

 

Filtering the 191xx Part-Number Range

 

Part-number filtering — read the size designation as Pairs x 2 x Cross-Section, then filter by pair count (1, 2, 3, 4, 5, 6, 8, 10 or 14 pairs) and the four gauges up to 1.0 mm²; all part numbers are five-digit 191xx codes.

 

C-PUR Part-Number Schedule

 

Complete part-number schedule for SUPER-PAAR-TRONIC-C-PUR paired continuous-flex PUR drag-chain data cable (all 32 configurations from 0.25 to 1.0 m㎡, strictly including AWG wire gauges and millimeter cross-sections):

 

01 SUPER-PAAR-TRONIC-C-PUR complete part-number schedule article numbers by pair count and cross-section two-column layout

 

Send Inquiry